Plasma volume is associated with micronutrient mass but not concentration in healthy US women of reproductive age

{"title":"Plasma volume is associated with micronutrient mass but not concentration in healthy US women of reproductive age","authors":"","doi":"10.1016/j.jtemin.2024.100187","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Plasma transports nutrients and composes more than half of the volume of blood. A few prior studies suggest that plasma volume fluctuations may impact certain micronutrient concentrations. We hypothesized a slight negative correlation between plasma volume and micronutrient biomarkers throughout the menstrual cycle in healthy women of reproductive age (<em>n</em> = 45).</p></div><div><h3>Methods</h3><p>The study involved three visits during one menstrual cycle where fasting blood samples were taken to measure biomarker concentrations for zinc, copper, magnesium, manganese, iron, ferritin, retinol, and hemoglobin. A bolus dose of indocyanine green (ICG; equivalent to 0.25 mg.kg<sup>-1</sup> of body weight) was injected to measure plasma volume. The total circulating micronutrient biomarker mass was calculated using the plasma volume and biomarker concentration. We used Spearman's correlation and fractional polynomial regression techniques to assess the relationship between plasma volume and biomarker concentration and mass.</p></div><div><h3>Results</h3><p>Plasma volume ranged from 1210 to 3520 mL. During all three visits, the correlation between micronutrient biomarker concentrations and plasma volume ranged from -0.05 to 0.10 (all <em>P</em> &gt; 0.05); However, there was a strong positive correlation between biomarker mass and plasma volume, ranging from 0.26 to 0.95 (all <em>P</em> &lt; 0.05). Five of the eight biomarkers examined (zinc, copper, magnesium, retinol, and hemoglobin) showed a correlation coefficient &gt; 0.70 (<em>P</em> &lt; 0.001) between mass and plasma volume.</p></div><div><h3>Conclusion</h3><p>Our findings indicate that biomarker concentrations are maintained across a range of plasma volume, suggesting that plasma volume may not be necessary to interpret micronutrient status in healthy non-pregnant women of reproductive age.</p></div>","PeriodicalId":73997,"journal":{"name":"Journal of trace elements and minerals","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-08-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2773050624000727/pdfft?md5=e328a88e7fd970187f3d1b20655327ed&pid=1-s2.0-S2773050624000727-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of trace elements and minerals","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2773050624000727","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Plasma transports nutrients and composes more than half of the volume of blood. A few prior studies suggest that plasma volume fluctuations may impact certain micronutrient concentrations. We hypothesized a slight negative correlation between plasma volume and micronutrient biomarkers throughout the menstrual cycle in healthy women of reproductive age (n = 45).

Methods

The study involved three visits during one menstrual cycle where fasting blood samples were taken to measure biomarker concentrations for zinc, copper, magnesium, manganese, iron, ferritin, retinol, and hemoglobin. A bolus dose of indocyanine green (ICG; equivalent to 0.25 mg.kg-1 of body weight) was injected to measure plasma volume. The total circulating micronutrient biomarker mass was calculated using the plasma volume and biomarker concentration. We used Spearman's correlation and fractional polynomial regression techniques to assess the relationship between plasma volume and biomarker concentration and mass.

Results

Plasma volume ranged from 1210 to 3520 mL. During all three visits, the correlation between micronutrient biomarker concentrations and plasma volume ranged from -0.05 to 0.10 (all P > 0.05); However, there was a strong positive correlation between biomarker mass and plasma volume, ranging from 0.26 to 0.95 (all P < 0.05). Five of the eight biomarkers examined (zinc, copper, magnesium, retinol, and hemoglobin) showed a correlation coefficient > 0.70 (P < 0.001) between mass and plasma volume.

Conclusion

Our findings indicate that biomarker concentrations are maintained across a range of plasma volume, suggesting that plasma volume may not be necessary to interpret micronutrient status in healthy non-pregnant women of reproductive age.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
美国健康育龄妇女的血浆容量与微量营养素的质量有关,但与浓度无关
背景血浆运输营养物质,占血液容积的一半以上。之前的一些研究表明,血浆容量的波动可能会影响某些微量营养素的浓度。我们假设在健康育龄妇女(n = 45)的整个月经周期中,血浆容量与微量营养素生物标志物之间存在轻微的负相关。注射吲哚菁绿(ICG,相当于 0.25 mg.kg-1(体重))来测量血浆容量。利用血浆容量和生物标记物浓度计算循环中微量营养素生物标记物的总质量。我们使用斯皮尔曼相关性和分数多项式回归技术来评估血浆容量与生物标志物浓度和质量之间的关系。在所有三次检查中,微量营养素生物标志物浓度与血浆容量之间的相关性从-0.05到0.10不等(所有P均为0.05);然而,生物标志物质量与血浆容量之间存在很强的正相关性,从0.26到0.95不等(所有P均为0.05)。结论我们的研究结果表明,生物标志物的浓度在一定范围内的血浆容量都能保持不变,这表明在健康的非怀孕育龄妇女中,血浆容量可能不是解释微量营养素状况的必要条件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of trace elements and minerals
Journal of trace elements and minerals Medicine and Dentistry (General), Analytical Chemistry, Environmental Science (General), Toxicology, Biochemistry, Genetics and Molecular Biology (General), Nutrition, Veterinary Science and Veterinary Medicine (General)
自引率
0.00%
发文量
0
审稿时长
65 days
期刊最新文献
Enhanced antibacterial effect of natural tannin stabilized silver nano particles against human pathogens: A target toward FtsZ proteins Hepatotoxicity induced by subacute exposure of Mancozeb and Arsenic in Wistar rats: Mitigating effect of quercetin and catechin Magnesium involvement in social behavior and in the treatment of some psychological disorders. A review Pollution evaluation and health risks assessment of naturally occurring toxic metals in shallow groundwater: A study in southwestern tidal delta of Bangladesh Total mercury and methylmercury levels in Brazilian Amazon fish: A scope review with meta-analysis and local population health risk assessment
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1