{"title":"Using computed tomography to evaluate anatomic landmarks in taiwanese trauma patients for insertion of resuscitative endovascular balloon occlusion of the aorta: A retrospective cohort study.","authors":"Chih-Ying Chien, Yueh-Lin Lee, Mei-Jy Jeng, Chia-Jen Liu","doi":"10.1097/JS9.0000000000002079","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Hemorrhage, particularly from non-compressible torso hemorrhage (NCTH) in the abdominopelvic region, is a leading cause of preventable trauma deaths. Resuscitative endovascular balloon occlusion of the aorta (REBOA), designed for aortic occlusion, has emerged as a tool for temporary hemorrhage control in recent years. However, attaining optimal REBOA placement in diverse demographic groups, such as Asian populations, may pose challenges owing to unique anatomical and physiological differences.</p><p><strong>Materials and methods: </strong>This retrospective study analyzed trauma patients who underwent torso computed tomography (CT) at tertiary hospitals in Taiwan from January 2014 to January 2017. The OsiriX software was used to measure the endovascular lengths in the CT images.</p><p><strong>Results: </strong>Among the 223 patients, the median vascular lengths and body measurements were higher in males. The optimal fixed insertion length was identified as 47.5 cm for zone 1 with 99.43% accuracy and 25.5 cm with 82.1% accuracy for zone 3. The landmark-guided method showed 100% accuracy for zone 1 when using the mid-sternum and 94.6% for zone 3 with the umbilicus as the guide with the distance between the umbilicus, xiphoid process, and pubic ramus. External validation confirmed the accuracy of the landmark-guided method.</p><p><strong>Conclusions: </strong>For zone 1 occlusions, a range of 44-48 cm insertion length cross-referenced with the mid-sternal landmark is recommended. For zone 3 occlusions, using the umbilicus as a guide with the distance between the umbilicus, xiphoid process, and pubic ramus provided the highest accuracy.</p>","PeriodicalId":14401,"journal":{"name":"International journal of surgery","volume":null,"pages":null},"PeriodicalIF":12.5000,"publicationDate":"2024-09-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/JS9.0000000000002079","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Hemorrhage, particularly from non-compressible torso hemorrhage (NCTH) in the abdominopelvic region, is a leading cause of preventable trauma deaths. Resuscitative endovascular balloon occlusion of the aorta (REBOA), designed for aortic occlusion, has emerged as a tool for temporary hemorrhage control in recent years. However, attaining optimal REBOA placement in diverse demographic groups, such as Asian populations, may pose challenges owing to unique anatomical and physiological differences.
Materials and methods: This retrospective study analyzed trauma patients who underwent torso computed tomography (CT) at tertiary hospitals in Taiwan from January 2014 to January 2017. The OsiriX software was used to measure the endovascular lengths in the CT images.
Results: Among the 223 patients, the median vascular lengths and body measurements were higher in males. The optimal fixed insertion length was identified as 47.5 cm for zone 1 with 99.43% accuracy and 25.5 cm with 82.1% accuracy for zone 3. The landmark-guided method showed 100% accuracy for zone 1 when using the mid-sternum and 94.6% for zone 3 with the umbilicus as the guide with the distance between the umbilicus, xiphoid process, and pubic ramus. External validation confirmed the accuracy of the landmark-guided method.
Conclusions: For zone 1 occlusions, a range of 44-48 cm insertion length cross-referenced with the mid-sternal landmark is recommended. For zone 3 occlusions, using the umbilicus as a guide with the distance between the umbilicus, xiphoid process, and pubic ramus provided the highest accuracy.
期刊介绍:
The International Journal of Surgery (IJS) has a broad scope, encompassing all surgical specialties. Its primary objective is to facilitate the exchange of crucial ideas and lines of thought between and across these specialties.By doing so, the journal aims to counter the growing trend of increasing sub-specialization, which can result in "tunnel-vision" and the isolation of significant surgical advancements within specific specialties.