Development and validation of a UPLC-MS/MS method for rapid and simultaneous quantification of BPI-460372 and its metabolites BPI-460444 and BPI-460456 in human plasma
Jianwei Ren , Hongzhong Liu , Yufang Ma , Wei Tian , Qinqin Li , Zhen Wu , Mengzhao Wang , Xiaoyun Liu , Xin Zheng , Xiaohong Han
{"title":"Development and validation of a UPLC-MS/MS method for rapid and simultaneous quantification of BPI-460372 and its metabolites BPI-460444 and BPI-460456 in human plasma","authors":"Jianwei Ren , Hongzhong Liu , Yufang Ma , Wei Tian , Qinqin Li , Zhen Wu , Mengzhao Wang , Xiaoyun Liu , Xin Zheng , Xiaohong Han","doi":"10.1016/j.jchromb.2024.124300","DOIUrl":null,"url":null,"abstract":"<div><p>In cancer development and progression, the Hippo signaling pathway functions. The transcriptional enhanced associate domain (TEAD) stands out as a pivotal transcription factor within this pathway, and the suppression of TEAD represents a promising approach for cancer treatment. The primary aim of the study was to establish an analytical method for the concurrent quantification of a novel TEAD target inhibitor, BPI-460372, and its principal metabolites, BPI-460444 and BPI-460456, in human plasma. The chromatographic separation utilized a XSelect™ HSS C<sub>18</sub> column (2.1 × 100 mm, 2.5 µm), while quantification was conducted on a SCIEX API 4000 mass spectrometer. 22 plasma samples were tested via the developed method. The calibration curve for BPI-460372 exhibited linearity from 2 to 2000 ng/mL, while its metabolites BPI-460444 and BPI-460456 had linearity between 1 and 1000 ng/mL (r > 0.99). The precision (RSD) was ≤ 17.1 %, and the accuracy (RE) fell within the range of −17.7 % to 15.0 %, all meeting acceptance criteria. The matrix effect was from 101.0 % to 105.8 %. The extraction recovery of analytes fell within the range of 96.8 % to 104.1 % with an RSD of less than 7.4 %. The developed method was effectively utilized in an advanced solid tumor patient, and the concentration trends of the three analytes in plasma were found to be largely consistent. The established analytical method showed great sensitivity, simplicity, accuracy, and reliability for the rapid and simultaneous analysis of the TEAD target inhibitor BPI-460372, alongside its major metabolites BPI-460444 and BPI-460456 in human plasma. This analytical method provided essential support for future clinical investigations and pharmacokinetic analysis.</p></div>","PeriodicalId":348,"journal":{"name":"Journal of Chromatography B","volume":"1247 ","pages":"Article 124300"},"PeriodicalIF":2.8000,"publicationDate":"2024-09-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chromatography B","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S157002322400309X","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
In cancer development and progression, the Hippo signaling pathway functions. The transcriptional enhanced associate domain (TEAD) stands out as a pivotal transcription factor within this pathway, and the suppression of TEAD represents a promising approach for cancer treatment. The primary aim of the study was to establish an analytical method for the concurrent quantification of a novel TEAD target inhibitor, BPI-460372, and its principal metabolites, BPI-460444 and BPI-460456, in human plasma. The chromatographic separation utilized a XSelect™ HSS C18 column (2.1 × 100 mm, 2.5 µm), while quantification was conducted on a SCIEX API 4000 mass spectrometer. 22 plasma samples were tested via the developed method. The calibration curve for BPI-460372 exhibited linearity from 2 to 2000 ng/mL, while its metabolites BPI-460444 and BPI-460456 had linearity between 1 and 1000 ng/mL (r > 0.99). The precision (RSD) was ≤ 17.1 %, and the accuracy (RE) fell within the range of −17.7 % to 15.0 %, all meeting acceptance criteria. The matrix effect was from 101.0 % to 105.8 %. The extraction recovery of analytes fell within the range of 96.8 % to 104.1 % with an RSD of less than 7.4 %. The developed method was effectively utilized in an advanced solid tumor patient, and the concentration trends of the three analytes in plasma were found to be largely consistent. The established analytical method showed great sensitivity, simplicity, accuracy, and reliability for the rapid and simultaneous analysis of the TEAD target inhibitor BPI-460372, alongside its major metabolites BPI-460444 and BPI-460456 in human plasma. This analytical method provided essential support for future clinical investigations and pharmacokinetic analysis.
期刊介绍:
The Journal of Chromatography B publishes papers on developments in separation science relevant to biology and biomedical research including both fundamental advances and applications. Analytical techniques which may be considered include the various facets of chromatography, electrophoresis and related methods, affinity and immunoaffinity-based methodologies, hyphenated and other multi-dimensional techniques, and microanalytical approaches. The journal also considers articles reporting developments in sample preparation, detection techniques including mass spectrometry, and data handling and analysis.
Developments related to preparative separations for the isolation and purification of components of biological systems may be published, including chromatographic and electrophoretic methods, affinity separations, field flow fractionation and other preparative approaches.