Svetlana Shachneva, Anna Lielpetere, Wolfgang Schuhmann
{"title":"Pencil-Lead-Based Quasi-Equilibrium Glucose Biosensors","authors":"Svetlana Shachneva, Anna Lielpetere, Wolfgang Schuhmann","doi":"10.1002/adsr.202400024","DOIUrl":null,"url":null,"abstract":"<p>Foreign body response is the main reason for the limited lifetime of implantable glucose biosensors. A new measurement strategy exerting minimal disturbance from the equilibrium glucose concentration in the sensor compartment has been proposed to mitigate its adverse effects on the sensor signal. Here, a new measurement strategy using automatically fabricated and robust pencil-lead-based glucose biosensors is implemented. The sensor response depends on critical parameters such as redox-polymer film thickness, film uniformity, rigidity, polymer composition, and the ratio between the enzyme and the polymer. These parameters are controlled by introducing a short-chain redox polymer, a low crosslinker amount, a short-chain electrografting agent and linker, pulse electrografting, and an automated fabrication procedure.</p>","PeriodicalId":100037,"journal":{"name":"Advanced Sensor Research","volume":"3 9","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-05-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/adsr.202400024","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced Sensor Research","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/adsr.202400024","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Foreign body response is the main reason for the limited lifetime of implantable glucose biosensors. A new measurement strategy exerting minimal disturbance from the equilibrium glucose concentration in the sensor compartment has been proposed to mitigate its adverse effects on the sensor signal. Here, a new measurement strategy using automatically fabricated and robust pencil-lead-based glucose biosensors is implemented. The sensor response depends on critical parameters such as redox-polymer film thickness, film uniformity, rigidity, polymer composition, and the ratio between the enzyme and the polymer. These parameters are controlled by introducing a short-chain redox polymer, a low crosslinker amount, a short-chain electrografting agent and linker, pulse electrografting, and an automated fabrication procedure.