Molecular Docking and Density Functional Studies of Selective Molecularly Imprinted Polymers Combined with an Electrochemical Sensor for the Detection of Malathion

IF 1 4区 化学 Q4 CHEMISTRY, ANALYTICAL Journal of Analytical Chemistry Pub Date : 2024-08-24 DOI:10.1134/S1061934824700527
Fariba Beigmoradi, Masoud Rohani Moghadam, Alireza Bazmandegan-Shamili
{"title":"Molecular Docking and Density Functional Studies of Selective Molecularly Imprinted Polymers Combined with an Electrochemical Sensor for the Detection of Malathion","authors":"Fariba Beigmoradi,&nbsp;Masoud Rohani Moghadam,&nbsp;Alireza Bazmandegan-Shamili","doi":"10.1134/S1061934824700527","DOIUrl":null,"url":null,"abstract":"<p>In this research, density functional theory and molecular docking calculations were utilized to select appropriate molecularly imprinted polymers (<b>MIP</b>s) for malathion (<b>MAL</b>). The MIP was synthesized with MAL as the template molecule, ethylene glycol dimethacrylate as the cross-linker, and methacrylic acid as the functional monomer on the surface of graphene quantum dots (<b>GQD</b>s). The MIPs were coated on GQDs to fabricate the GQDs@MIP sensor. The electrochemical sensor was characterized by Fourier-transform infrared spectroscopy, X-ray scattering spectroscopy, and field-emission scanning electron microscopy. Parameters affecting the electrochemical response of MAL, including the GQDs@MIP percentage amount, pH of the rebinding solution, pH of the analysis solution, and incubation time, were optimized. Differential pulse voltammetry revealed a linear calibration curve in the concentration range of 0.01 to 55.00 µM with a limit of detection of 1.5 nM. The relative standard deviation for five consecutive tests of 1.00 μM MAL was 2.2%. The GQDs@MIP sensor was successfully applied to determine MAL in various fruit samples.</p>","PeriodicalId":606,"journal":{"name":"Journal of Analytical Chemistry","volume":"79 8","pages":"1143 - 1158"},"PeriodicalIF":1.0000,"publicationDate":"2024-08-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1134/S1061934824700527","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

In this research, density functional theory and molecular docking calculations were utilized to select appropriate molecularly imprinted polymers (MIPs) for malathion (MAL). The MIP was synthesized with MAL as the template molecule, ethylene glycol dimethacrylate as the cross-linker, and methacrylic acid as the functional monomer on the surface of graphene quantum dots (GQDs). The MIPs were coated on GQDs to fabricate the GQDs@MIP sensor. The electrochemical sensor was characterized by Fourier-transform infrared spectroscopy, X-ray scattering spectroscopy, and field-emission scanning electron microscopy. Parameters affecting the electrochemical response of MAL, including the GQDs@MIP percentage amount, pH of the rebinding solution, pH of the analysis solution, and incubation time, were optimized. Differential pulse voltammetry revealed a linear calibration curve in the concentration range of 0.01 to 55.00 µM with a limit of detection of 1.5 nM. The relative standard deviation for five consecutive tests of 1.00 μM MAL was 2.2%. The GQDs@MIP sensor was successfully applied to determine MAL in various fruit samples.

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
结合电化学传感器检测马拉硫磷的选择性分子印迹聚合物的分子对接和密度函数研究
摘要 在这项研究中,利用密度泛函理论和分子对接计算选择了合适的马拉硫磷(MAL)分子印迹聚合物(MIPs)。以马拉硫磷为模板分子,乙二醇二甲基丙烯酸酯为交联剂,甲基丙烯酸为功能单体,在石墨烯量子点(GQDs)表面合成了分子印迹聚合物(MIP)。在石墨烯量子点上涂覆 MIP 后,就制成了 GQDs@MIP 传感器。傅立叶变换红外光谱、X 射线散射光谱和场发射扫描电子显微镜对该电化学传感器进行了表征。对影响 MAL 电化学响应的参数进行了优化,包括 GQDs@MIP 的百分比量、重结合溶液的 pH 值、分析溶液的 pH 值和孵育时间。差分脉冲伏安法在 0.01 至 55.00 µM 的浓度范围内显示出线性校准曲线,检测限为 1.5 nM。连续五次检测 1.00 μM MAL 的相对标准偏差为 2.2%。GQDs@MIP 传感器被成功应用于检测各种水果样品中的 MAL。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Analytical Chemistry
Journal of Analytical Chemistry 化学-分析化学
CiteScore
2.10
自引率
9.10%
发文量
146
审稿时长
13 months
期刊介绍: The Journal of Analytical Chemistry is an international peer reviewed journal that covers theoretical and applied aspects of analytical chemistry; it informs the reader about new achievements in analytical methods, instruments and reagents. Ample space is devoted to problems arising in the analysis of vital media such as water and air. Consideration is given to the detection and determination of metal ions, anions, and various organic substances. The journal welcomes manuscripts from all countries in the English or Russian language.
期刊最新文献
Separation of Chlorogenic Acids and Caffeine on a Diasfer-110-C10CN Stationary Phase Development, Validation, and Quantification of Organic Impurities with Mass Balance in the Levodopa and Benserazide Hydrochloride Pharmaceutical Dosage Form Surface-Assisted Laser Desorption/Ionization of Metal Complexes with Dithizone Determination of Potassium, Neodymium, and Strontium in Solid Solutions in the KNd(SO4)2·H2O–SrSO4·0.5H2O System Using X-Ray Fluorescence Spectrometry Thin-Layer Chromatography of Methylated Derivatives of Linear Alkylbenzene Sulfonates in Water Analysis by Gas Chromatography–Mass Spectrometry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1