Changes in physiological signal entropy in patients with obstructive sleep apnoea: a systematic review.

IF 2.3 4区 医学 Q3 BIOPHYSICS Physiological measurement Pub Date : 2024-09-11 DOI:10.1088/1361-6579/ad79b4
Nawal Ziyad Alotaibi,Maggie Cheung,Amar Shah,John Hurst,Alireza Mani,Swapna Mandal
{"title":"Changes in physiological signal entropy in patients with obstructive sleep apnoea: a systematic review.","authors":"Nawal Ziyad Alotaibi,Maggie Cheung,Amar Shah,John Hurst,Alireza Mani,Swapna Mandal","doi":"10.1088/1361-6579/ad79b4","DOIUrl":null,"url":null,"abstract":"Background and Objective Obstructive sleep apnoea (OSA) affects an estimated 936 million people worldwide, yet only 15% receive a definitive diagnosis. Diagnosis of OSA poses challenges due to the dynamic nature of physiological signals such as oxygen saturation (SpO2) and heart rate variability (HRV). Linear analysis methods may not fully capture the irregularities present in these signals. The application of entropy of routine physiological signals offers a promising method to better measure variabilities in dynamic biological data. This review aims to explore entropy changes in physiological signals among individuals with OSA.
Methods Keyword and title searches were performed on Medline, Embase, Scopus, and CINAHL databases. Studies had to analyse physiological signals in OSA using entropy. Quality assessment used the Newcastle-Ottawa Scale. Evidence was qualitatively synthesized, considering entropy signals, entropy type, and time-series length.
Main results Twenty-two studies were included. Multiple physiological signals related to OSA, including SpO2, HRV, and the oxygen desaturation index (ODI), have been investigated using entropy. Results revealed a significant decrease in HRV entropy in those with OSA compared to control groups. Conversely, SpO2 and ODI entropy values were increased in OSA. Despite variations in entropy types, time scales, and data extraction devices, studies using receiver operating characteristic (ROC) curves demonstrated a high discriminative accuracy (>80% AUC) in distinguishing OSA patients from control groups. 
Conclusions This review highlights the potential of SpO2 entropy analysis in developing new diagnostic indices for patients with OSA. Further investigation is needed before applying this technique clinically.
&#xD.","PeriodicalId":20047,"journal":{"name":"Physiological measurement","volume":"152 1","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2024-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physiological measurement","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6579/ad79b4","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background and Objective Obstructive sleep apnoea (OSA) affects an estimated 936 million people worldwide, yet only 15% receive a definitive diagnosis. Diagnosis of OSA poses challenges due to the dynamic nature of physiological signals such as oxygen saturation (SpO2) and heart rate variability (HRV). Linear analysis methods may not fully capture the irregularities present in these signals. The application of entropy of routine physiological signals offers a promising method to better measure variabilities in dynamic biological data. This review aims to explore entropy changes in physiological signals among individuals with OSA. Methods Keyword and title searches were performed on Medline, Embase, Scopus, and CINAHL databases. Studies had to analyse physiological signals in OSA using entropy. Quality assessment used the Newcastle-Ottawa Scale. Evidence was qualitatively synthesized, considering entropy signals, entropy type, and time-series length. Main results Twenty-two studies were included. Multiple physiological signals related to OSA, including SpO2, HRV, and the oxygen desaturation index (ODI), have been investigated using entropy. Results revealed a significant decrease in HRV entropy in those with OSA compared to control groups. Conversely, SpO2 and ODI entropy values were increased in OSA. Despite variations in entropy types, time scales, and data extraction devices, studies using receiver operating characteristic (ROC) curves demonstrated a high discriminative accuracy (>80% AUC) in distinguishing OSA patients from control groups. Conclusions This review highlights the potential of SpO2 entropy analysis in developing new diagnostic indices for patients with OSA. Further investigation is needed before applying this technique clinically. .
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
阻塞性睡眠呼吸暂停患者生理信号熵的变化:系统综述。
背景和目的 据估计,全球有 9.36 亿人患有阻塞性睡眠呼吸暂停(OSA),但只有 15%的人得到明确诊断。由于血氧饱和度(SpO2)和心率变异性(HRV)等生理信号的动态性质,OSA 的诊断面临挑战。线性分析方法可能无法完全捕捉到这些信号中存在的不规则性。常规生理信号熵的应用为更好地测量动态生物数据中的变异性提供了一种很有前景的方法。本综述旨在探讨 OSA 患者生理信号的熵变化。方法 在 Medline、Embase、Scopus 和 CINAHL 数据库中进行关键词和标题检索。研究必须使用熵分析 OSA 的生理信号。采用纽卡斯尔-渥太华量表进行质量评估。考虑到熵信号、熵类型和时间序列长度,对证据进行了定性综合。使用熵对与 OSA 相关的多种生理信号进行了研究,包括 SpO2、心率变异和氧饱和度指数 (ODI)。结果显示,与对照组相比,OSA 患者的心率变异熵明显下降。相反,SpO2 和 ODI 的熵值在 OSA 患者中有所增加。尽管熵的类型、时间尺度和数据提取设备各不相同,但使用接收器操作特征曲线(ROC)进行的研究表明,在区分 OSA 患者和对照组时,熵的鉴别准确率很高(AUC >80%)。在将此技术应用于临床之前,还需要进一步的研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Physiological measurement
Physiological measurement 生物-工程:生物医学
CiteScore
5.50
自引率
9.40%
发文量
124
审稿时长
3 months
期刊介绍: Physiological Measurement publishes papers about the quantitative assessment and visualization of physiological function in clinical research and practice, with an emphasis on the development of new methods of measurement and their validation. Papers are published on topics including: applied physiology in illness and health electrical bioimpedance, optical and acoustic measurement techniques advanced methods of time series and other data analysis biomedical and clinical engineering in-patient and ambulatory monitoring point-of-care technologies novel clinical measurements of cardiovascular, neurological, and musculoskeletal systems. measurements in molecular, cellular and organ physiology and electrophysiology physiological modeling and simulation novel biomedical sensors, instruments, devices and systems measurement standards and guidelines.
期刊最新文献
Telephone training to improve ECG quality in remote screening for atrial fibrillation. Amplitude spectrum area is dependent on the electrocardiogram magnitude: evaluation of different normalization approaches. Comparison of automatic and physiologically-based feature selection methods for classifying physiological stress using heart rate and pulse rate variability indices. Beat the heat: wearable-based study of perceived heat stress and physiological strain in Swiss track workers in a controlled climate chamber. A skewed-Gaussian model for pulse decomposition analysis of photoplethysmography signals.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1