L. Ferasin , H. Ferasin , J. Farminer , E. Hudson , K. Lamb
{"title":"Diagnostic value of a point-of-care cardiac troponin-I assay (i-STAT®) for clinical application in canine and feline cardiology","authors":"L. Ferasin , H. Ferasin , J. Farminer , E. Hudson , K. Lamb","doi":"10.1016/j.jvc.2024.07.006","DOIUrl":null,"url":null,"abstract":"<div><h3><strong>Introduction/Objectives</strong></h3><p>This study was performed to evaluate the diagnostic value and net benefits, including cost-effectiveness, of a point-of-care analyser (i-STAT®) for measurement of cardiac troponin I (cTnI) in dogs and cats.</p></div><div><h3><strong>Animals, Materials and Methods</strong></h3><p>120 dogs and 120 cats presented with signs of cardiac disease and suspected myocardial insult on cardiac assessment. This was a validation study expressed as agreement between the i-STAT® analyser and two common commercial reference methods (IMMULITE® 2000 and ACCESS® hsTnI).</p></div><div><h3><strong>Results</strong></h3><p>The comparison between methods showed a negative bias between the i–STAT® and the two commercial cTnI assays. The bias was more evident when the i-STAT® values were compared to the traditional cTnI assay (IMMULITE® 2000), with a calculated difference of −1.14 ng/mL (dogs) and −0.96 ng/mL (cats). However, the bias was distinctly lower when the i-STAT® measurements were compared to the high-sensitivity cTnI assay (ACCESS®), namely −0.3 ng/mL in dogs and −0.17 in cats.</p></div><div><h3><strong>Discussion</strong></h3><p>The i-STAT® method can reliably detect normal, low and elevated cTnI values, which is fundamental to differentiate pets with and without myocardial damage and, with the rapid availability of results, this confirms the clinical utility of the i-STAT® method.</p></div><div><h3>Conclusions</h3><p>cTnI concentrations measured with the i-STAT® have good comparability with those obtained with both commercial assays for low and elevated cTnI values. However, results should be cautiously interpreted for high troponin values, especially if a strict cut-off value is adopted for diagnostic or prognostic purposes in critical clinical conditions, such as myocarditis or acute myocardial ischaemia.</p></div>","PeriodicalId":48788,"journal":{"name":"Journal of Veterinary Cardiology","volume":"56 ","pages":"Pages 35-43"},"PeriodicalIF":1.5000,"publicationDate":"2024-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Veterinary Cardiology","FirstCategoryId":"97","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1760273424000791","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction/Objectives
This study was performed to evaluate the diagnostic value and net benefits, including cost-effectiveness, of a point-of-care analyser (i-STAT®) for measurement of cardiac troponin I (cTnI) in dogs and cats.
Animals, Materials and Methods
120 dogs and 120 cats presented with signs of cardiac disease and suspected myocardial insult on cardiac assessment. This was a validation study expressed as agreement between the i-STAT® analyser and two common commercial reference methods (IMMULITE® 2000 and ACCESS® hsTnI).
Results
The comparison between methods showed a negative bias between the i–STAT® and the two commercial cTnI assays. The bias was more evident when the i-STAT® values were compared to the traditional cTnI assay (IMMULITE® 2000), with a calculated difference of −1.14 ng/mL (dogs) and −0.96 ng/mL (cats). However, the bias was distinctly lower when the i-STAT® measurements were compared to the high-sensitivity cTnI assay (ACCESS®), namely −0.3 ng/mL in dogs and −0.17 in cats.
Discussion
The i-STAT® method can reliably detect normal, low and elevated cTnI values, which is fundamental to differentiate pets with and without myocardial damage and, with the rapid availability of results, this confirms the clinical utility of the i-STAT® method.
Conclusions
cTnI concentrations measured with the i-STAT® have good comparability with those obtained with both commercial assays for low and elevated cTnI values. However, results should be cautiously interpreted for high troponin values, especially if a strict cut-off value is adopted for diagnostic or prognostic purposes in critical clinical conditions, such as myocarditis or acute myocardial ischaemia.
期刊介绍:
The mission of the Journal of Veterinary Cardiology is to publish peer-reviewed reports of the highest quality that promote greater understanding of cardiovascular disease, and enhance the health and well being of animals and humans. The Journal of Veterinary Cardiology publishes original contributions involving research and clinical practice that include prospective and retrospective studies, clinical trials, epidemiology, observational studies, and advances in applied and basic research.
The Journal invites submission of original manuscripts. Specific content areas of interest include heart failure, arrhythmias, congenital heart disease, cardiovascular medicine, surgery, hypertension, health outcomes research, diagnostic imaging, interventional techniques, genetics, molecular cardiology, and cardiovascular pathology, pharmacology, and toxicology.