{"title":"A directed grey incidence model based on panel data","authors":"Yanli Zhai, Gege Luo, Dang Luo","doi":"10.1108/gs-02-2024-0025","DOIUrl":null,"url":null,"abstract":"<h3>Purpose</h3>\n<p>The purpose of this paper is to construct a grey incidence model for panel data that can reflect the incidence direction and degree between indicators.</p><!--/ Abstract__block -->\n<h3>Design/methodology/approach</h3>\n<p>Firstly, this paper introduces the concept of a negative matrix and preprocesses the data of each indicator matrix to eliminate differences in dimensions and magnitudes between indicators. Then a model is constructed to measure the incidence direction and degree between indicators, and the properties of the model are studied. Finally, the model is applied to a practical problem.</p><!--/ Abstract__block -->\n<h3>Findings</h3>\n<p>The grey-directed incidence degree is 1 if and only if corresponding elements between the feature indicator matrix and the factor indicator matrix have a positive linear relationship. This degree is −1 if and only if corresponding elements between the feature indicator matrix and the factor indicator matrix have a negative linear relationship.</p><!--/ Abstract__block -->\n<h3>Practical implications</h3>\n<p>The example shows the number of days with good air quality is negatively correlated with the annual average concentration of each pollutant index. <em>PM</em><sub>2.5</sub>, <em>PM</em><sub><sub>10</sub></sub> and <em>O</em><sub><sub>3</sub></sub> are the main pollutants affecting air quality in northern Henan.</p><!--/ Abstract__block -->\n<h3>Originality/value</h3>\n<p>This paper introduces the negative matrix and constructs a model from the holistic perspective to measure the incidence direction and level between indicators. This model can effectively measure the incidence between the feature indicator and factor indicator by integrating information from the point, row, column and matrix.</p><!--/ Abstract__block -->","PeriodicalId":48597,"journal":{"name":"Grey Systems-Theory and Application","volume":"106 1","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2024-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Grey Systems-Theory and Application","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1108/gs-02-2024-0025","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MATHEMATICS, INTERDISCIPLINARY APPLICATIONS","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

The purpose of this paper is to construct a grey incidence model for panel data that can reflect the incidence direction and degree between indicators.

Design/methodology/approach

Firstly, this paper introduces the concept of a negative matrix and preprocesses the data of each indicator matrix to eliminate differences in dimensions and magnitudes between indicators. Then a model is constructed to measure the incidence direction and degree between indicators, and the properties of the model are studied. Finally, the model is applied to a practical problem.

Findings

The grey-directed incidence degree is 1 if and only if corresponding elements between the feature indicator matrix and the factor indicator matrix have a positive linear relationship. This degree is −1 if and only if corresponding elements between the feature indicator matrix and the factor indicator matrix have a negative linear relationship.

Practical implications

The example shows the number of days with good air quality is negatively correlated with the annual average concentration of each pollutant index. PM2.5, PM10 and O3 are the main pollutants affecting air quality in northern Henan.

Originality/value

This paper introduces the negative matrix and constructs a model from the holistic perspective to measure the incidence direction and level between indicators. This model can effectively measure the incidence between the feature indicator and factor indicator by integrating information from the point, row, column and matrix.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于面板数据的定向灰色发生率模型
设计/方法/途径首先,本文引入负矩阵的概念,对各指标矩阵的数据进行预处理,消除指标间维度和幅度的差异。然后构建了一个模型来衡量指标间的入射方向和程度,并对模型的特性进行了研究。结论当且仅当特征指标矩阵和因素指标矩阵之间的对应元素具有正线性关系时,灰色方向入射度为 1。实际意义该示例表明,空气质量良好的天数与各污染物指数的年平均浓度呈负相关。PM2.5、PM10 和 O3 是影响豫北地区空气质量的主要污染物。该模型综合了点、行、列和矩阵的信息,可有效衡量特征指标与因子指标之间的入射关系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Grey Systems-Theory and Application
Grey Systems-Theory and Application MATHEMATICS, INTERDISCIPLINARY APPLICATIONS-
CiteScore
4.80
自引率
13.80%
发文量
22
期刊最新文献
Forecasting short-term energy consumption in Chongqing using a novel grey Bernoulli model Construction and application of a novel grey relational analysis model considering factor coupling relationship A directed grey incidence model based on panel data A grey target performance evaluation model for aeroengine pressure test bench Grey relations
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1