CTC and CT5TEA: an advanced multi-channel digitizer and trigger ASIC for imaging atmospheric Cherenkov telescopes

Benjamin Schwab, Adrian Zink, Davide Depaoli, Jim Hinton, Gang Liu, Akira Okumura, Duncan Ross, Johannes Schäfer, Harm Schoorlemmer, Hiro Tajima, Justin Vandenbroucke, Richard White, Jason John Watson, Justus Zorn, Stefan Funk
{"title":"CTC and CT5TEA: an advanced multi-channel digitizer and trigger ASIC for imaging atmospheric Cherenkov telescopes","authors":"Benjamin Schwab, Adrian Zink, Davide Depaoli, Jim Hinton, Gang Liu, Akira Okumura, Duncan Ross, Johannes Schäfer, Harm Schoorlemmer, Hiro Tajima, Justin Vandenbroucke, Richard White, Jason John Watson, Justus Zorn, Stefan Funk","doi":"arxiv-2409.06435","DOIUrl":null,"url":null,"abstract":"We have developed a new set of Application-Specific Integrated Circuits\n(ASICs) of the TARGET family (CTC and CT5TEA), designed for the readout of\nsignals from photosensors in cameras of Imaging Atmospheric Cherenkov\nTelescopes (IACTs) for ground-based gamma-ray astronomy. We present the\nperformance and design details. Both ASICs feature 16 channels, with CTC being\na Switched-Capacitor Array (SCA) sampler at 0.5 to 1 GSa/s with a 16,384 sample\ndeep storage buffer, including the functionality to digitize full waveforms at\narbitrary times. CT5TEA is its companion trigger ASIC (though may be used on\nits own), which provides trigger information for the analog sum of four (and\n16) adjacent channels. Since sampling and triggering takes place in two\nseparate ASICs, the noise due to interference from the SCA is suppressed, and\nallows a minimal trigger threshold of $\\leq$ 2.5 mV (0.74 photo electrons\n(p.e.)) with a trigger noise of $\\leq$ 0.5 mV (0.15 p.e.). For CTC, a maximal\ninput voltage range from $-$0.5 V up to 1.7 V is achieved with an effective bit\nrange of $>$ 11.6 bits and a baseline noise of 0.7 mV. The cross-talk improved\nto $\\leq$ 1% over the whole $-$3 dB bandwidth of 220 MHz and even down to 0.2%\nfor 1.5 V pulses of 10 ns width. Not only is the performance presented, but a\ntemperature-stable calibration routine for pulse mode operation is introduced\nand validated. The resolution is found to be $\\sim$ 2.5% at 33.7 mV (10 p.e.)\nand $\\leq$ 0.3% at 337 mV (100 p.e.) with an integrated non-linearity of $<$\n1.6 mV. Developed for the Small-Sized Telescope (SST) and Schwarzschild-Couder\nTelescope (SCT) cameras of the Cherenkov Telescope Array Observatory (CTAO),\nCTC and CT5TEA are deployed for both prototypes and shall be integrated into\nthe final versions.","PeriodicalId":501163,"journal":{"name":"arXiv - PHYS - Instrumentation and Methods for Astrophysics","volume":"25 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"arXiv - PHYS - Instrumentation and Methods for Astrophysics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/arxiv-2409.06435","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

We have developed a new set of Application-Specific Integrated Circuits (ASICs) of the TARGET family (CTC and CT5TEA), designed for the readout of signals from photosensors in cameras of Imaging Atmospheric Cherenkov Telescopes (IACTs) for ground-based gamma-ray astronomy. We present the performance and design details. Both ASICs feature 16 channels, with CTC being a Switched-Capacitor Array (SCA) sampler at 0.5 to 1 GSa/s with a 16,384 sample deep storage buffer, including the functionality to digitize full waveforms at arbitrary times. CT5TEA is its companion trigger ASIC (though may be used on its own), which provides trigger information for the analog sum of four (and 16) adjacent channels. Since sampling and triggering takes place in two separate ASICs, the noise due to interference from the SCA is suppressed, and allows a minimal trigger threshold of $\leq$ 2.5 mV (0.74 photo electrons (p.e.)) with a trigger noise of $\leq$ 0.5 mV (0.15 p.e.). For CTC, a maximal input voltage range from $-$0.5 V up to 1.7 V is achieved with an effective bit range of $>$ 11.6 bits and a baseline noise of 0.7 mV. The cross-talk improved to $\leq$ 1% over the whole $-$3 dB bandwidth of 220 MHz and even down to 0.2% for 1.5 V pulses of 10 ns width. Not only is the performance presented, but a temperature-stable calibration routine for pulse mode operation is introduced and validated. The resolution is found to be $\sim$ 2.5% at 33.7 mV (10 p.e.) and $\leq$ 0.3% at 337 mV (100 p.e.) with an integrated non-linearity of $<$ 1.6 mV. Developed for the Small-Sized Telescope (SST) and Schwarzschild-Couder Telescope (SCT) cameras of the Cherenkov Telescope Array Observatory (CTAO), CTC and CT5TEA are deployed for both prototypes and shall be integrated into the final versions.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
CTC 和 CT5TEA:用于大气切伦科夫望远镜成像的先进多通道数字转换器和触发器 ASIC
我们开发了一套新的 TARGET 系列专用集成电路(ASIC)(CTC 和 CT5TEA),设计用于读取地面伽马射线天文学成像大气切伦科夫望远镜(IACT)相机中光敏传感器的信号。我们将介绍其性能和设计细节。这两个 ASIC 都具有 16 个通道,其中 CTC 是一个开关电容阵列(SCA)采样器,采样速度为 0.5 至 1 GSa/s,具有 16,384 个采样深度存储缓冲器,包括以任意时间数字化全波形的功能。CT5TEA 是其配套的触发器 ASIC(也可单独使用),为四个(和 16 个)相邻通道的模拟和提供触发信息。由于采样和触发是在两个独立的 ASIC 中进行的,因此抑制了 SCA 干扰造成的噪声,允许最小触发阈值为 $\leq$ 2.5 mV(0.74 光电),触发噪声为 $\leq$ 0.5 mV(0.15 光电)。对于 CTC,最大输入电压范围从 $-$0.5 V 到 1.7 V,有效比特范围为 $>$11.6 比特,基线噪声为 0.7 mV。在 220 MHz 的整个 $-$3 dB 带宽范围内,串扰降低到了 $/leq$ 1%,对于 10 ns 宽度的 1.5 V 脉冲,串扰甚至降低到了 0.2%。不仅介绍了性能,还介绍并验证了脉冲模式操作的温度稳定校准程序。33.7 mV(10 p.e.)时的分辨率为 2.5%,337 mV(100 p.e.)时的分辨率为 0.3%,综合非线性度小于 1.6 mV。CTC和CT5TEA是为切伦科夫望远镜阵列天文台(CTAO)的小型望远镜(SST)和施瓦兹希尔德-考德尔望远镜(SCT)照相机开发的,这两个原型机都部署了CTC和CT5TEA,并将集成到最终版本中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Bright unintended electromagnetic radiation from second-generation Starlink satellites Likelihood reconstruction of radio signals of neutrinos and cosmic rays An evaluation of source-blending impact on the calibration of SKA EoR experiments WALLABY Pilot Survey: HI source-finding with a machine learning framework Black Hole Accretion is all about Sub-Keplerian Flows
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1