{"title":"Machine Learning-Based X-Ray Projection Interpolation for Improved 4D-CBCT Reconstruction","authors":"Jayroop Ramesh;Donthi Sankalpa;Rohan Mitra;Salam Dhou","doi":"10.1109/OJEMB.2024.3459622","DOIUrl":null,"url":null,"abstract":"<italic>Goal:</i>\n Respiration-correlated cone-beam computed tomography (4D-CBCT) is an X-ray-based imaging modality that uses reconstruction algorithms to produce time-varying volumetric images of moving anatomy over a cycle of respiratory motion. The quality of the produced images is affected by the number of CBCT projections available for reconstruction. Interpolation techniques have been used to generate intermediary projections to be used, along with the original projections, for reconstruction. Transfer learning is a powerful approach that harnesses the ability to reuse pre-trained models in solving new problems. \n<italic>Methods:</i>\n Several state-of-the-art pre-trained deep learning models, used for video frame interpolation, are utilized in this work to generate intermediary projections. Moreover, a novel regression predictive modeling approach is also proposed to achieve the same objective. Digital phantom and clinical datasets are used to evaluate the performance of the models. \n<italic>Results:</i>\n The results show that the Real-Time Intermediate Flow Estimation (RIFE) algorithm outperforms the others in terms of the Structural Similarity Index Method (SSIM): 0.986 \n<inline-formula><tex-math>$\\pm$</tex-math></inline-formula>\n 0.010, Peak Signal to Noise Ratio (PSNR): 44.13 \n<inline-formula><tex-math>$\\pm$</tex-math></inline-formula>\n 2.76, and Mean Square Error (MSE): 18.86 \n<inline-formula><tex-math>$\\pm$</tex-math></inline-formula>\n 206.90 across all datasets. Moreover, the interpolated projections were used along with the original ones to reconstruct a 4D-CBCT image that was compared to that reconstructed from the original projections only. \n<italic>Conclusions:</i>\n The reconstructed image using the proposed approach was found to minimize the streaking artifacts, thereby enhancing the image quality. This work demonstrates the advantage of using general-purpose transfer learning algorithms in 4D-CBCT image enhancement.","PeriodicalId":33825,"journal":{"name":"IEEE Open Journal of Engineering in Medicine and Biology","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2024-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10678916","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Open Journal of Engineering in Medicine and Biology","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10678916/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Goal: Respiration-correlated cone-beam computed tomography (4D-CBCT) is an X-ray-based imaging modality that uses reconstruction algorithms to produce time-varying volumetric images of moving anatomy over a cycle of respiratory motion. The quality of the produced images is affected by the number of CBCT projections available for reconstruction. Interpolation techniques have been used to generate intermediary projections to be used, along with the original projections, for reconstruction. Transfer learning is a powerful approach that harnesses the ability to reuse pre-trained models in solving new problems. Methods: Several state-of-the-art pre-trained deep learning models, used for video frame interpolation, are utilized in this work to generate intermediary projections. Moreover, a novel regression predictive modeling approach is also proposed to achieve the same objective. Digital phantom and clinical datasets are used to evaluate the performance of the models. Results: The results show that the Real-Time Intermediate Flow Estimation (RIFE) algorithm outperforms the others in terms of the Structural Similarity Index Method (SSIM): 0.986 $\pm$ 0.010, Peak Signal to Noise Ratio (PSNR): 44.13 $\pm$ 2.76, and Mean Square Error (MSE): 18.86 $\pm$ 206.90 across all datasets. Moreover, the interpolated projections were used along with the original ones to reconstruct a 4D-CBCT image that was compared to that reconstructed from the original projections only. Conclusions: The reconstructed image using the proposed approach was found to minimize the streaking artifacts, thereby enhancing the image quality. This work demonstrates the advantage of using general-purpose transfer learning algorithms in 4D-CBCT image enhancement.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于机器学习的 X 射线投影插值用于改进 4D-CBCT 重建
目标:呼吸相关锥束计算机断层扫描(4D-CBCT)是一种基于 X 射线的成像模式,它使用重建算法生成呼吸运动周期中移动解剖结构的时变容积图像。生成图像的质量受可用于重建的 CBCT 投影数量的影响。插值技术被用来生成中间投影,与原始投影一起用于重建。迁移学习是一种功能强大的方法,它能在解决新问题时重复使用预先训练好的模型。方法:本研究利用几个用于视频帧插值的最先进的预训练深度学习模型来生成中间投影。此外,还提出了一种新颖的回归预测建模方法,以实现相同的目标。数字模型和临床数据集用于评估模型的性能。结果显示结果表明,在所有数据集上,实时中间流估计(RIFE)算法在结构相似性指数法(SSIM):0.986 $\pm$ 0.010、峰值信噪比(PSNR):44.13 $\pm$ 2.76和均方误差(MSE):18.86 $\pm$ 206.90方面均优于其他算法。此外,内插投影与原始投影一起用于重建 4D-CBCT 图像,并与仅由原始投影重建的图像进行比较。结论使用建议方法重建的图像能最大限度地减少条纹伪影,从而提高图像质量。这项工作证明了在 4D-CBCT 图像增强中使用通用迁移学习算法的优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
9.50
自引率
3.40%
发文量
20
审稿时长
10 weeks
期刊介绍: The IEEE Open Journal of Engineering in Medicine and Biology (IEEE OJEMB) is dedicated to serving the community of innovators in medicine, technology, and the sciences, with the core goal of advancing the highest-quality interdisciplinary research between these disciplines. The journal firmly believes that the future of medicine depends on close collaboration between biology and technology, and that fostering interaction between these fields is an important way to advance key discoveries that can improve clinical care.IEEE OJEMB is a gold open access journal in which the authors retain the copyright to their papers and readers have free access to the full text and PDFs on the IEEE Xplore® Digital Library. However, authors are required to pay an article processing fee at the time their paper is accepted for publication, using to cover the cost of publication.
期刊最新文献
Corrections to “Gastric Section Correlation Network for Gastric Precancerous Lesion Diagnosis” IEEE Open Journal of Engineering in Medicine and Biology Editorial Board Information IEEE Open Journal of Engineering in Medicine and Biology Author Instructions Guest Editorial: Introduction to the Special Series on Advances in Cardiovascular and Respiratory Systems Engineering Front Cover
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1