A high-performance wearable microneedle sensor based on a carboxylated carbon nanotube-carbon nanotube composite electrode for the simultaneous detection of uric acid and dopamine

IF 4.9 2区 化学 Q1 CHEMISTRY, ANALYTICAL Microchemical Journal Pub Date : 2024-09-10 DOI:10.1016/j.microc.2024.111607
Jiachen Zhu, Weiliang Wang, Gang Chen, Tian Gao, Zhiyong Gao, Liang Peng, Luwen Wang, Wei Cai
{"title":"A high-performance wearable microneedle sensor based on a carboxylated carbon nanotube-carbon nanotube composite electrode for the simultaneous detection of uric acid and dopamine","authors":"Jiachen Zhu, Weiliang Wang, Gang Chen, Tian Gao, Zhiyong Gao, Liang Peng, Luwen Wang, Wei Cai","doi":"10.1016/j.microc.2024.111607","DOIUrl":null,"url":null,"abstract":"Uric acid (UA) and dopamine (DA) are crucial biomarkers in the human body. However, there is limited research on detecting UA or DA in subcutaneous interstitial fluid (SISF), and no studies on their simultaneous detection in SISF. Here, we developed an electrochemical microneedle sensor based on the carboxylated carbon nanotubes/multiwalled carbon nanotubes (CCNT/CNT) composite electrode for the simultaneous detection of UA and DA. Highly carboxylated CCNT was prepared and mixed with CNT and organosilicon-modified acrylic resin to form the CCNT/CNT composite. The carboxyl functional groups of CCNT enhance the electrode’s adsorption of UA and DA, while CNT improves electron conduction. The sensor achieves a wide linear detection range for UA (5–600 μM) with high sensitivity (7.13 μA μM cm) and linearity (R = 0.994), as well as a wide linear range for DA (2–200 μM) with high sensitivity (13.31 μA μM cm) and linearity (R = 0.994). The sensor achieved simultaneous detection of DA and UA in artificial interstitial fluid (ISF), with sensitivity and linearity remaining nearly unchanged compared to that in PBS, and is not affected by high levels of ascorbic acid (AA). Finally, the sensor successfully detected changes in UA levels in ISF of subjects before and after alcohol consumption , demonstrating its practical application capabilities. This study presents a practical strategy for detecting human biomarkers characterized by low cost, easy fabrication and excellent performance of electrode materials, and a well-designed microneedle sensor preparation scheme, making it highly promising for further research extension.","PeriodicalId":391,"journal":{"name":"Microchemical Journal","volume":null,"pages":null},"PeriodicalIF":4.9000,"publicationDate":"2024-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microchemical Journal","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1016/j.microc.2024.111607","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Uric acid (UA) and dopamine (DA) are crucial biomarkers in the human body. However, there is limited research on detecting UA or DA in subcutaneous interstitial fluid (SISF), and no studies on their simultaneous detection in SISF. Here, we developed an electrochemical microneedle sensor based on the carboxylated carbon nanotubes/multiwalled carbon nanotubes (CCNT/CNT) composite electrode for the simultaneous detection of UA and DA. Highly carboxylated CCNT was prepared and mixed with CNT and organosilicon-modified acrylic resin to form the CCNT/CNT composite. The carboxyl functional groups of CCNT enhance the electrode’s adsorption of UA and DA, while CNT improves electron conduction. The sensor achieves a wide linear detection range for UA (5–600 μM) with high sensitivity (7.13 μA μM cm) and linearity (R = 0.994), as well as a wide linear range for DA (2–200 μM) with high sensitivity (13.31 μA μM cm) and linearity (R = 0.994). The sensor achieved simultaneous detection of DA and UA in artificial interstitial fluid (ISF), with sensitivity and linearity remaining nearly unchanged compared to that in PBS, and is not affected by high levels of ascorbic acid (AA). Finally, the sensor successfully detected changes in UA levels in ISF of subjects before and after alcohol consumption , demonstrating its practical application capabilities. This study presents a practical strategy for detecting human biomarkers characterized by low cost, easy fabrication and excellent performance of electrode materials, and a well-designed microneedle sensor preparation scheme, making it highly promising for further research extension.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于羧基碳纳米管-碳纳米管复合电极的高性能可穿戴微针传感器,用于同时检测尿酸和多巴胺
尿酸(UA)和多巴胺(DA)是人体内重要的生物标志物。然而,在皮下间质(SISF)中检测尿酸或多巴胺的研究非常有限,也没有在 SISF 中同时检测这两种物质的研究。在此,我们开发了一种基于羧基碳纳米管/多壁碳纳米管(CCNT/CNT)复合电极的电化学微针传感器,用于同时检测 UA 和 DA。制备了高羧基化 CCNT,并将其与 CNT 和有机硅改性丙烯酸树脂混合形成 CCNT/CNT 复合材料。CCNT 的羧基官能团增强了电极对 UA 和 DA 的吸附,而 CNT 则改善了电子传导。该传感器实现了 UA(5-600 μM)的宽线性检测范围、高灵敏度(7.13 μA μM cm)和线性度(R = 0.994),以及 DA(2-200 μM)的宽线性检测范围、高灵敏度(13.31 μA μM cm)和线性度(R = 0.994)。该传感器可同时检测人工间质液(ISF)中的 DA 和 UA,灵敏度和线性度与 PBS 中的几乎没有变化,并且不受高浓度抗坏血酸(AA)的影响。最后,该传感器成功检测出了饮酒前后受试者 ISF 中 UA 含量的变化,证明了其实际应用能力。这项研究提出了一种检测人体生物标志物的实用策略,其特点是成本低、电极材料易于制造且性能优良,同时还设计了一种精心制作的微针传感器方案,因此非常有希望进一步推广研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Microchemical Journal
Microchemical Journal 化学-分析化学
CiteScore
8.70
自引率
8.30%
发文量
1131
审稿时长
1.9 months
期刊介绍: The Microchemical Journal is a peer reviewed journal devoted to all aspects and phases of analytical chemistry and chemical analysis. The Microchemical Journal publishes articles which are at the forefront of modern analytical chemistry and cover innovations in the techniques to the finest possible limits. This includes fundamental aspects, instrumentation, new developments, innovative and novel methods and applications including environmental and clinical field. Traditional classical analytical methods such as spectrophotometry and titrimetry as well as established instrumentation methods such as flame and graphite furnace atomic absorption spectrometry, gas chromatography, and modified glassy or carbon electrode electrochemical methods will be considered, provided they show significant improvements and novelty compared to the established methods.
期刊最新文献
Preparation and characterization of Maillard reaction products from enzymatic hydrolysate products of abalone viscera Electrochemical detection of quercetin at a Pt nanoaggregate-decorated Ti3C2-modified electrode Eco-friendly Synthesis of Silver-Doped Reduced Graphene Oxide Nanocomposite, The Characterization, and Evaluation of Electrochemical Activity Colorimetric detection of benzoate in the beverage using the peroxidase-like properties of single-atom Fe-N-C nanozymes A high-performance wearable microneedle sensor based on a carboxylated carbon nanotube-carbon nanotube composite electrode for the simultaneous detection of uric acid and dopamine
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1