{"title":"Novel Parameter Identification Method of Extended Debye Model for Long-Length Submarine Cables","authors":"Siyan Lin;Kai Zhou;Yuan Li","doi":"10.1109/TDEI.2024.3453232","DOIUrl":null,"url":null,"abstract":"To address the challenge of acquiring detailed insulation status for long-length submarine cables, this article proposes a branch parameter identification method without manual thresholds, based on an extended Debye model (EDM) and the polarization depolarization current method. First, depolarization current is used to construct a Hankel matrix, and the singular values and incremental sequences of information entropy are acquired by step. Subsequently, the matrix pencil (MP) algorithm is employed to determine the branches with the highest amplitudes, which are successively removed from the original signal. The number of branches is confirmed by minimizing the variance of the information entropy increment sequences according to the characteristics of white noise. Simulation results demonstrate that the proposed method achieves high accuracy even at SNR =30 dB. Moreover, the proposed method remains accurate even when there are significant differences in branch amplitudes. Finally, the proposed method is applied to four in-service submarine cables, and the results are corroborated through comparisons with data obtained from the frequency domain reflection (FDR) method and temperature-measuring optical fiber; thus, validating the effectiveness of the proposed method.","PeriodicalId":13247,"journal":{"name":"IEEE Transactions on Dielectrics and Electrical Insulation","volume":"31 5","pages":"2652-2660"},"PeriodicalIF":2.9000,"publicationDate":"2024-09-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Dielectrics and Electrical Insulation","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10662953/","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

To address the challenge of acquiring detailed insulation status for long-length submarine cables, this article proposes a branch parameter identification method without manual thresholds, based on an extended Debye model (EDM) and the polarization depolarization current method. First, depolarization current is used to construct a Hankel matrix, and the singular values and incremental sequences of information entropy are acquired by step. Subsequently, the matrix pencil (MP) algorithm is employed to determine the branches with the highest amplitudes, which are successively removed from the original signal. The number of branches is confirmed by minimizing the variance of the information entropy increment sequences according to the characteristics of white noise. Simulation results demonstrate that the proposed method achieves high accuracy even at SNR =30 dB. Moreover, the proposed method remains accurate even when there are significant differences in branch amplitudes. Finally, the proposed method is applied to four in-service submarine cables, and the results are corroborated through comparisons with data obtained from the frequency domain reflection (FDR) method and temperature-measuring optical fiber; thus, validating the effectiveness of the proposed method.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于长距离海底电缆的扩展德拜模型的新型参数识别方法
为解决获取长距离海底电缆详细绝缘状态的难题,本文基于扩展德拜模型(EDM)和极化去极化电流法,提出了一种无人工阈值的分支参数识别方法。首先,利用去极化电流构建汉克尔矩阵,并逐步获取奇异值和信息熵增量序列。随后,采用矩阵铅笔(MP)算法确定振幅最大的分支,并从原始信号中依次去除。根据白噪声的特点,通过最小化信息熵增量序列的方差来确认分支的数量。仿真结果表明,即使在信噪比为 30 dB 时,所提出的方法也能达到很高的精度。此外,即使在分支振幅存在显著差异的情况下,所提出的方法仍能保持准确性。最后,将所提方法应用于四条在役海底电缆,通过与频域反射(FDR)方法和测温光纤获得的数据进行比较,证实了所提方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
IEEE Transactions on Dielectrics and Electrical Insulation
IEEE Transactions on Dielectrics and Electrical Insulation 工程技术-工程:电子与电气
CiteScore
6.00
自引率
22.60%
发文量
309
审稿时长
5.2 months
期刊介绍: Topics that are concerned with dielectric phenomena and measurements, with development and characterization of gaseous, vacuum, liquid and solid electrical insulating materials and systems; and with utilization of these materials in circuits and systems under condition of use.
期刊最新文献
Table of Contents IEEE Transactions on Dielectrics and Electrical Insulation Publication Information Editorial Electrets and Related Phenomena IEEE Transactions on Dielectrics and Electrical Insulation Information for Authors IEEE Dielectrics and Electrical Insulation Society Information
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1