Development and validation of spectrophotometric methods for estimation of arrhythmias drug-dronedarone hydrochloride in pure and dosage forms

IF 4.1 Q1 CHEMISTRY, ANALYTICAL Talanta Open Pub Date : 2024-09-12 DOI:10.1016/j.talo.2024.100355
Ragaa El Sheikh , Ayman A. Gouda , Ahmed A. Ghazy , Nesma M. Jumaa , Noha E.M. Elsaify , Nehal S.A. Soliman , Asmaa El Sayed , Ahmed H. Moustafa , Ahmad O. Babalghith , Ahmed El Sayed , Al-Sayed M.Abd El-Majeed
{"title":"Development and validation of spectrophotometric methods for estimation of arrhythmias drug-dronedarone hydrochloride in pure and dosage forms","authors":"Ragaa El Sheikh ,&nbsp;Ayman A. Gouda ,&nbsp;Ahmed A. Ghazy ,&nbsp;Nesma M. Jumaa ,&nbsp;Noha E.M. Elsaify ,&nbsp;Nehal S.A. Soliman ,&nbsp;Asmaa El Sayed ,&nbsp;Ahmed H. Moustafa ,&nbsp;Ahmad O. Babalghith ,&nbsp;Ahmed El Sayed ,&nbsp;Al-Sayed M.Abd El-Majeed","doi":"10.1016/j.talo.2024.100355","DOIUrl":null,"url":null,"abstract":"<div><p>Sensitive, simple, and accurate spectrophotometric methods have been developed for the assay of arrhythmias drug-dronedarone hydrochloride (DND) in bulk drug and pharmaceutical formulations. The proposed method is based on the oxidation reaction of DND with a known excess of cerium(IV) ammonium sulfate (Ce(IV)) as an oxidizing agent in acid medium, followed by the determination of the unreacted oxidant by adding a fixed amount of dye, e.g., amaranth (AM), methylene blue (MB), and indigocarmine (IC), followed by measuring the absorbance at 520, 664, and 610 nm, respectively. The effects of experimental conditions were studied and optimized. The beer's law was obeyed in the concentration ranges of 1.0–10, 1.0–15, and 1.0–8.0 μg mL<sup>-1</sup> using AM, MB, and IC dyes, respectively, with a correlation coefficient ≥ 0.9992. The calculated molar absorptivity values are 3.6527 × 10<sup>4</sup>, 3.1212 × 10<sup>4</sup>, and 4.229 × 10<sup>4</sup> L mol<sup>-1</sup> cm<sup>-1</sup> using AM, MB, and IC dyes, respectively. The limits of detection and quantification were 0.30 and 1.0 µg mL<sup>-1</sup>, respectively, for the three methods. Intra-day and inter-day accuracy and precision of the methods have been evaluated. No interference was observed from the additives. The proposed methods were successfully applied to the assay of DND in tablet preparations and the results were statistically compared with those of the reported method by applying Student's <em>t</em>-test and F-test. The reliability of the methods was further ascertained by performing recovery studies using the standard addition method.</p></div>","PeriodicalId":436,"journal":{"name":"Talanta Open","volume":"10 ","pages":"Article 100355"},"PeriodicalIF":4.1000,"publicationDate":"2024-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666831924000699/pdfft?md5=f8ecd77d8a8d7d158b1cb91bf04e548c&pid=1-s2.0-S2666831924000699-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta Open","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666831924000699","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Sensitive, simple, and accurate spectrophotometric methods have been developed for the assay of arrhythmias drug-dronedarone hydrochloride (DND) in bulk drug and pharmaceutical formulations. The proposed method is based on the oxidation reaction of DND with a known excess of cerium(IV) ammonium sulfate (Ce(IV)) as an oxidizing agent in acid medium, followed by the determination of the unreacted oxidant by adding a fixed amount of dye, e.g., amaranth (AM), methylene blue (MB), and indigocarmine (IC), followed by measuring the absorbance at 520, 664, and 610 nm, respectively. The effects of experimental conditions were studied and optimized. The beer's law was obeyed in the concentration ranges of 1.0–10, 1.0–15, and 1.0–8.0 μg mL-1 using AM, MB, and IC dyes, respectively, with a correlation coefficient ≥ 0.9992. The calculated molar absorptivity values are 3.6527 × 104, 3.1212 × 104, and 4.229 × 104 L mol-1 cm-1 using AM, MB, and IC dyes, respectively. The limits of detection and quantification were 0.30 and 1.0 µg mL-1, respectively, for the three methods. Intra-day and inter-day accuracy and precision of the methods have been evaluated. No interference was observed from the additives. The proposed methods were successfully applied to the assay of DND in tablet preparations and the results were statistically compared with those of the reported method by applying Student's t-test and F-test. The reliability of the methods was further ascertained by performing recovery studies using the standard addition method.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
开发和验证用于估算纯品和剂型中心律失常药物-盐酸决奈达隆的分光光度法
本研究开发了灵敏、简单、准确的分光光度法,用于检测散装药物和药物制剂中的心律失常药物-盐酸决奈达隆(DND)。所提出的方法是以已知过量的硫酸铵铈(Ce(IV))为氧化剂,在酸性介质中对 DND 进行氧化反应,然后加入一定量的染料(如苋菜红(AM)、亚甲基蓝(MB)和靛红(IC)),分别在 520、664 和 610 纳米波长处测量吸光度,以测定未反应的氧化剂。对实验条件的影响进行了研究和优化。在 AM、MB 和 IC 染料的浓度范围分别为 1.0-10、1.0-15 和 1.0-8.0 μg mL-1 时,均符合啤酒定律,相关系数≥ 0.9992。使用 AM、MB 和 IC 染料计算的摩尔吸收率值分别为 3.6527 × 104、3.1212 × 104 和 4.229 × 104 L mol-1 cm-1。三种方法的检测和定量限分别为 0.30 和 1.0 µg mL-1。对方法的日内和日间准确度和精密度进行了评估。没有发现添加剂的干扰。建议的方法成功地应用于片剂中 DND 的检测,并通过学生 t 检验和 F 检验将结果与报告的方法进行了统计比较。通过使用标准添加法进行回收率研究,进一步确定了方法的可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Talanta Open
Talanta Open Chemistry-Analytical Chemistry
CiteScore
5.20
自引率
0.00%
发文量
86
审稿时长
49 days
期刊最新文献
Continuous-flow analysis of nitrogen compounds in environmental water using a copper–zinc reduction coil Development of engineered Zn-MOF/g-C3N4 based photoelectrochemical system for real-time sensors and removal of naproxen in wastewater Development of nanomaterial-supported molecularly imprinted polymer/receptor-like sensor for the detection of rosuvastatin from binary mixtures Trace-level quantification of NDMA in levosulpuride active pharmaceutical ingredient and tablet formulation Using UFLC-MS/MS Enhancing isomer specificity in mass spectrometry by combining silver ion adduction and ion mobility
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1