Dual-tube MEMS-based spectrophone for sub-ppb mid-IR photoacoustic gas detection

IF 7.1 1区 医学 Q1 ENGINEERING, BIOMEDICAL Photoacoustics Pub Date : 2024-09-12 DOI:10.1016/j.pacs.2024.100644
Stefano Dello Russo , Jacopo Pelini , Inaki Lopez Garcia , Maria Concetta Canino , Alberto Roncaglia , Pablo Cancio Pastor , Iacopo Galli , Paolo De Natale , Simone Borri , Mario Siciliani de Cumis
{"title":"Dual-tube MEMS-based spectrophone for sub-ppb mid-IR photoacoustic gas detection","authors":"Stefano Dello Russo ,&nbsp;Jacopo Pelini ,&nbsp;Inaki Lopez Garcia ,&nbsp;Maria Concetta Canino ,&nbsp;Alberto Roncaglia ,&nbsp;Pablo Cancio Pastor ,&nbsp;Iacopo Galli ,&nbsp;Paolo De Natale ,&nbsp;Simone Borri ,&nbsp;Mario Siciliani de Cumis","doi":"10.1016/j.pacs.2024.100644","DOIUrl":null,"url":null,"abstract":"<div><p>Nowadays, the scientific community and industry are increasingly pressed to provide solutions for developing compact and highly-performing trace-gas sensors for several applications of crucial importance, such as environmental monitoring or medical diagnostics. In this context, this work describes a novel configuration, making use of a mid-IR spectrophone combining the compactness of a photo-acoustic setup, a non-conventional micro-electro-mechanical (MEMS) acousto-to-voltage transducer, and the sensitivity enhancement given by a cost-effective and easy-to-build dual-tube resonator configuration. In the optimal condition of sample pressure, the system developed in this work can achieve a minimum detection limit (MDL) equal to 0.34 ppb when averaging up to 10 s. Compared with previous literature of single-pass photoacoustic-based sensors for N<span><math><msub><mrow></mrow><mrow><mn>2</mn></mrow></msub></math></span>O, this corresponds to a significant improvement both for the achieved normalized noise equivalent absorption coefficient (NNEA) equal to 1.41 × 10<span><math><msup><mrow></mrow><mrow><mo>−</mo><mn>9</mn></mrow></msup></math></span> cm<span><math><msup><mrow></mrow><mrow><mo>−</mo><mn>1</mn></mrow></msup></math></span>WHz<span><math><msup><mrow></mrow><mrow><mo>−</mo><mn>1</mn><mo>/</mo><mn>2</mn></mrow></msup></math></span>, and for a Noise-Equivalent-Concentration (NEC) of 1 ppb obtained at 1 s of averaging time.</p></div>","PeriodicalId":56025,"journal":{"name":"Photoacoustics","volume":"40 ","pages":"Article 100644"},"PeriodicalIF":7.1000,"publicationDate":"2024-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2213597924000612/pdfft?md5=f4adaa6788c8a0b00dcd269e0288213d&pid=1-s2.0-S2213597924000612-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Photoacoustics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2213597924000612","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Nowadays, the scientific community and industry are increasingly pressed to provide solutions for developing compact and highly-performing trace-gas sensors for several applications of crucial importance, such as environmental monitoring or medical diagnostics. In this context, this work describes a novel configuration, making use of a mid-IR spectrophone combining the compactness of a photo-acoustic setup, a non-conventional micro-electro-mechanical (MEMS) acousto-to-voltage transducer, and the sensitivity enhancement given by a cost-effective and easy-to-build dual-tube resonator configuration. In the optimal condition of sample pressure, the system developed in this work can achieve a minimum detection limit (MDL) equal to 0.34 ppb when averaging up to 10 s. Compared with previous literature of single-pass photoacoustic-based sensors for N2O, this corresponds to a significant improvement both for the achieved normalized noise equivalent absorption coefficient (NNEA) equal to 1.41 × 109 cm1WHz1/2, and for a Noise-Equivalent-Concentration (NEC) of 1 ppb obtained at 1 s of averaging time.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于 MEMS 的双管分光计,用于亚ppb 中红外光声气体检测
如今,科学界和工业界越来越迫切地需要提供解决方案,为环境监测或医疗诊断等一些至关重要的应用开发结构紧凑、性能卓越的痕量气体传感器。在此背景下,这项工作介绍了一种新颖的配置,即利用中红外分光传声器,将光声装置的紧凑性、非常规微机电(MEMS)声压换能器以及成本效益高且易于制造的双管谐振器配置所带来的灵敏度提升结合在一起。与之前基于单通道光声传感器的 N2O 文献相比,无论是归一化噪声等效吸收系数(NNEA)(1.41 × 10-9 cm-1WHz-1/2),还是平均时间为 1 秒时的噪声等效浓度(NEC)(1 ppb),都有显著提高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Photoacoustics
Photoacoustics Physics and Astronomy-Atomic and Molecular Physics, and Optics
CiteScore
11.40
自引率
16.50%
发文量
96
审稿时长
53 days
期刊介绍: The open access Photoacoustics journal (PACS) aims to publish original research and review contributions in the field of photoacoustics-optoacoustics-thermoacoustics. This field utilizes acoustical and ultrasonic phenomena excited by electromagnetic radiation for the detection, visualization, and characterization of various materials and biological tissues, including living organisms. Recent advancements in laser technologies, ultrasound detection approaches, inverse theory, and fast reconstruction algorithms have greatly supported the rapid progress in this field. The unique contrast provided by molecular absorption in photoacoustic-optoacoustic-thermoacoustic methods has allowed for addressing unmet biological and medical needs such as pre-clinical research, clinical imaging of vasculature, tissue and disease physiology, drug efficacy, surgery guidance, and therapy monitoring. Applications of this field encompass a wide range of medical imaging and sensing applications, including cancer, vascular diseases, brain neurophysiology, ophthalmology, and diabetes. Moreover, photoacoustics-optoacoustics-thermoacoustics is a multidisciplinary field, with contributions from chemistry and nanotechnology, where novel materials such as biodegradable nanoparticles, organic dyes, targeted agents, theranostic probes, and genetically expressed markers are being actively developed. These advanced materials have significantly improved the signal-to-noise ratio and tissue contrast in photoacoustic methods.
期刊最新文献
Quantitative volumetric photoacoustic assessment of vasoconstriction by topical corticosteroid application in mice skin Spiral volumetric optoacoustic and ultrasound (SVOPUS) tomography of mice Miniature optical fiber photoacoustic spectroscopy gas sensor based on a 3D micro-printed planar-spiral spring optomechanical resonator Calibration-free infrared absorption spectroscopy using cantilever-enhanced photoacoustic detection of the optical power Application of multispectral optoacoustic tomography for lower limb musculoskeletal sports injuries in adults
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1