Optical phase nullification partially restores visual and stereo acuity lost to simulated blur from higher-order wavefront aberrations of keratoconic eyes

IF 1.5 4区 心理学 Q4 NEUROSCIENCES Vision Research Pub Date : 2024-09-18 DOI:10.1016/j.visres.2024.108486
Bhagya Lakshmi Marella , Miriam L. Conway , Pravin K. Vaddavalli , Catherine M. Suttle , Shrikant R. Bharadwaj
{"title":"Optical phase nullification partially restores visual and stereo acuity lost to simulated blur from higher-order wavefront aberrations of keratoconic eyes","authors":"Bhagya Lakshmi Marella ,&nbsp;Miriam L. Conway ,&nbsp;Pravin K. Vaddavalli ,&nbsp;Catherine M. Suttle ,&nbsp;Shrikant R. Bharadwaj","doi":"10.1016/j.visres.2024.108486","DOIUrl":null,"url":null,"abstract":"<div><p>Contrast demodulation and phase distortions are exaggerated in retinal images blurred by the higher-order wavefront aberrations of keratoconic eyes. While the performance loss from the former parameter is well understood, little is known about the impact of the latter on visual functions in this disease condition. The present study investigated the impact of phase distortions on the monocular logMAR visual acuity, letter discriminability and random-dot stereoacuity of seventeen visually healthy adults (ten for visual acuity and letter discriminability; ten for stereoacuity and three common to both experiments) using images that were computationally blurred by four different higher-order wavefront aberration profiles of keratoconic eyes that showed significant distortions in the phase spectrum. Participants viewed these images through 2 mm artificial pupils to negate their native ocular wavefront aberrations. The results showed progressive losses in visual acuity and stereoacuity with increasing blur, a third of which could be recovered following phase nullification. Letter discriminability also improved following phase nullification, more so for smaller than larger optotypes. Stereoacuity loss and, consequently, its recovery following phase nullification was more prominent for profiles simulating unilateral asymmetric keratoconus than for profiles simulating bilateral symmetric keratoconus. These results agree with previous reports obtained from blur induced with lower-order aberrations and indicate that a similar trend may be observed for more complex patterns of blur like keratoconus. Overall, both contrast demodulation and misalignment of the local features of the blurred image may contribute to losses of spatial and depth vision in keratoconus. Phase nullification may partially mitigate these losses, thereby allowing the processing of finer spatial details and veridical disparity estimations for improved depth perception.</p></div>","PeriodicalId":23670,"journal":{"name":"Vision Research","volume":"224 ","pages":"Article 108486"},"PeriodicalIF":1.5000,"publicationDate":"2024-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vision Research","FirstCategoryId":"102","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0042698924001305","RegionNum":4,"RegionCategory":"心理学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"NEUROSCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Contrast demodulation and phase distortions are exaggerated in retinal images blurred by the higher-order wavefront aberrations of keratoconic eyes. While the performance loss from the former parameter is well understood, little is known about the impact of the latter on visual functions in this disease condition. The present study investigated the impact of phase distortions on the monocular logMAR visual acuity, letter discriminability and random-dot stereoacuity of seventeen visually healthy adults (ten for visual acuity and letter discriminability; ten for stereoacuity and three common to both experiments) using images that were computationally blurred by four different higher-order wavefront aberration profiles of keratoconic eyes that showed significant distortions in the phase spectrum. Participants viewed these images through 2 mm artificial pupils to negate their native ocular wavefront aberrations. The results showed progressive losses in visual acuity and stereoacuity with increasing blur, a third of which could be recovered following phase nullification. Letter discriminability also improved following phase nullification, more so for smaller than larger optotypes. Stereoacuity loss and, consequently, its recovery following phase nullification was more prominent for profiles simulating unilateral asymmetric keratoconus than for profiles simulating bilateral symmetric keratoconus. These results agree with previous reports obtained from blur induced with lower-order aberrations and indicate that a similar trend may be observed for more complex patterns of blur like keratoconus. Overall, both contrast demodulation and misalignment of the local features of the blurred image may contribute to losses of spatial and depth vision in keratoconus. Phase nullification may partially mitigate these losses, thereby allowing the processing of finer spatial details and veridical disparity estimations for improved depth perception.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
光学相位归零可部分恢复角膜炎患者因高阶波前像差造成的模拟模糊而丧失的视觉和立体视力
角膜病变眼睛的高阶波前像差会使视网膜图像的对比度解调和相位失真加剧。虽然前一种参数造成的性能损失已广为人知,但后一种参数对这种疾病条件下视觉功能的影响却知之甚少。本研究调查了相位畸变对 17 名视力健康的成年人(视力和字母辨别力为 10 人;立体视力为 10 人,两项实验共用 3 人)的单眼 logMAR 视敏度、字母辨别力和随机点立体视力的影响。受试者通过 2 毫米的人工瞳孔观看这些图像,以抵消其眼球波前像差。结果显示,随着模糊度的增加,视敏度和立体清晰度逐渐下降,其中三分之一的视敏度和立体清晰度在相位失效后可以恢复。字母辨别力也在相位失效后得到改善,小视窗比大视窗的改善幅度更大。对于模拟单侧非对称角膜屈光不正的轮廓来说,立体视力的损失比模拟双侧对称角膜屈光不正的轮廓更明显,因此,相位归零后立体视力的恢复也更明显。这些结果与之前从低阶像差引起的模糊中获得的报告一致,并表明对于更复杂的模糊模式,如角膜塑形镜,也可能观察到类似的趋势。总之,对比度解调和模糊图像局部特征的错位可能会导致角膜塑形镜的空间和深度视觉损失。相位无效化可以部分缓解这些损失,从而允许处理更精细的空间细节和进行真实的差距估计,以改善深度知觉。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Vision Research
Vision Research 医学-神经科学
CiteScore
3.70
自引率
16.70%
发文量
111
审稿时长
66 days
期刊介绍: Vision Research is a journal devoted to the functional aspects of human, vertebrate and invertebrate vision and publishes experimental and observational studies, reviews, and theoretical and computational analyses. Vision Research also publishes clinical studies relevant to normal visual function and basic research relevant to visual dysfunction or its clinical investigation. Functional aspects of vision is interpreted broadly, ranging from molecular and cellular function to perception and behavior. Detailed descriptions are encouraged but enough introductory background should be included for non-specialists. Theoretical and computational papers should give a sense of order to the facts or point to new verifiable observations. Papers dealing with questions in the history of vision science should stress the development of ideas in the field.
期刊最新文献
The effects of feedback and task accuracy in serial dependence to orientation. Emerging strategies targeting genes and cells in glaucoma. Scene complexity and the detail trace of human long-term visual memory. Trans-saccadic integration for object recognition peters out with pre-saccadic object eccentricity as target-directed saccades become more saliency-driven Visual comfort models based on coloured text and neutral background combinations
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1