Electrically evoked late latency response using single electrode stimulation and its relation to speech perception among paediatric cochlear implant users

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2024-09-13 DOI:10.3389/fnhum.2024.1441854
Palani Saravanan, Neelamegarajan Devi, Chinnaraj Geetha
{"title":"Electrically evoked late latency response using single electrode stimulation and its relation to speech perception among paediatric cochlear implant users","authors":"Palani Saravanan, Neelamegarajan Devi, Chinnaraj Geetha","doi":"10.3389/fnhum.2024.1441854","DOIUrl":null,"url":null,"abstract":"IntroductionAided auditory late latency response (LLR) serves as an objective tool for evaluating auditory cortical maturation following cochlear implantation in children. While aided LLR is commonly measured using sound-field acoustic stimulation, recording electrically evoked LLR (eLLR) offer distinct advantages, such as improved stimulus control and the capability for single electrode stimulation. Hence, the study aimed to compare eLLR responses with single electrode stimulation in the apical, middle, and basal regions and to evaluate their relationship with speech perception in paediatric cochlear implant (CI) recipients.MethodeLLR responses with single electrode stimulation were measured in 27 paediatric unilateral CI users with an active recording electrode placed at Cz. The stimuli consisted of 36 msec biphasic pulse trains presented across three electrode sites (apical-E20, middle-E11, and basal-E03). eLLR responses were compared across these electrode sites, and the relationship between speech recognition scores in quiet and age at implantation with eLLR components was evaluated.ResultseLLR responses were detected in 77 out of 81 tested electrodes of all participants combined (27 for apical, 26 for middle, and 24 for basal stimulation). There were no significant differences in P1, N1 latencies and P1 amplitude across electrode site. However, significantly larger N1 and P1-N1 amplitudes were observed for apical stimulations compared to basal stimulations. No differences in N1 amplitude were found between middle and apical stimulations, and the P1-N1 amplitude was significantly larger for middle compared to basal electrode stimulation, with no difference between the apical and middle electrodes stimulation. A moderate positive correlation was present between speech recognition scores in quiet and both N1, P1-N1 amplitudes for apical stimulation. Age at implantation was negatively correlated with N1 amplitude for the apical and P1-N1 amplitude for basal stimulation.DiscussioneLLR responses could be elicited in majority of paediatric CI users across electrode sites. Variations in eLLR responses across electrode sites suggest disparities in auditory cortical maturation. The findings underscore the significance of the N1 biomarker in evaluating higher-order auditory cortical development. Therefore, utilizing eLLR with single electrode stimulation may serve as a valuable tool for assessing post-cochlear implantation maturational changes in paediatric populations.","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3389/fnhum.2024.1441854","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

Abstract

IntroductionAided auditory late latency response (LLR) serves as an objective tool for evaluating auditory cortical maturation following cochlear implantation in children. While aided LLR is commonly measured using sound-field acoustic stimulation, recording electrically evoked LLR (eLLR) offer distinct advantages, such as improved stimulus control and the capability for single electrode stimulation. Hence, the study aimed to compare eLLR responses with single electrode stimulation in the apical, middle, and basal regions and to evaluate their relationship with speech perception in paediatric cochlear implant (CI) recipients.MethodeLLR responses with single electrode stimulation were measured in 27 paediatric unilateral CI users with an active recording electrode placed at Cz. The stimuli consisted of 36 msec biphasic pulse trains presented across three electrode sites (apical-E20, middle-E11, and basal-E03). eLLR responses were compared across these electrode sites, and the relationship between speech recognition scores in quiet and age at implantation with eLLR components was evaluated.ResultseLLR responses were detected in 77 out of 81 tested electrodes of all participants combined (27 for apical, 26 for middle, and 24 for basal stimulation). There were no significant differences in P1, N1 latencies and P1 amplitude across electrode site. However, significantly larger N1 and P1-N1 amplitudes were observed for apical stimulations compared to basal stimulations. No differences in N1 amplitude were found between middle and apical stimulations, and the P1-N1 amplitude was significantly larger for middle compared to basal electrode stimulation, with no difference between the apical and middle electrodes stimulation. A moderate positive correlation was present between speech recognition scores in quiet and both N1, P1-N1 amplitudes for apical stimulation. Age at implantation was negatively correlated with N1 amplitude for the apical and P1-N1 amplitude for basal stimulation.DiscussioneLLR responses could be elicited in majority of paediatric CI users across electrode sites. Variations in eLLR responses across electrode sites suggest disparities in auditory cortical maturation. The findings underscore the significance of the N1 biomarker in evaluating higher-order auditory cortical development. Therefore, utilizing eLLR with single electrode stimulation may serve as a valuable tool for assessing post-cochlear implantation maturational changes in paediatric populations.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用单电极刺激的电诱发晚期潜伏反应及其与小儿人工耳蜗使用者言语感知的关系
引言 辅助听觉晚期潜伏反应(LLR)是评估儿童人工耳蜗植入后听觉皮质成熟度的客观工具。虽然辅助 LLR 通常使用声场声学刺激进行测量,但记录电诱发 LLR(eLLR)具有明显的优势,如更好的刺激控制和单电极刺激能力。因此,本研究旨在比较单电极刺激在耳尖、中间和基底区域产生的电诱发 LLR 反应,并评估它们与小儿人工耳蜗(CI)植入者的言语感知之间的关系。对这些电极部位的 eLLR 反应进行了比较,并评估了安静状态下的语音识别分数和植入年龄与 eLLR 成分之间的关系。结果在所有参与者的 81 个测试电极中,有 77 个电极检测到了 eLLR 反应(其中 27 个电极检测到了耳尖反应,26 个电极检测到了中间反应,24 个电极检测到了基底反应)。不同电极部位的 P1、N1 延迟和 P1 振幅无明显差异。然而,与基底刺激相比,在心尖刺激下观察到的 N1 和 P1-N1 振幅明显更大。中间电极和根尖电极刺激的 N1 振幅没有差异,中间电极刺激的 P1-N1 振幅明显大于基底电极刺激的 P1-N1 振幅,根尖电极和中间电极刺激的 P1-N1 振幅没有差异。安静时的语音识别得分与心尖刺激时的 N1、P1-N1 振幅之间存在中等程度的正相关。植入年龄与根尖刺激的 N1 振幅和基底刺激的 P1-N1 振幅呈负相关。不同电极部位 eLLR 反应的差异表明听觉皮层的成熟度存在差异。这些发现强调了 N1 生物标记在评估高阶听觉皮层发育方面的重要性。因此,利用单电极刺激的 eLLR 可作为评估儿童人工耳蜗植入后成熟变化的重要工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1