{"title":"Effect of Electrode Montage on Frequency Tuning Properties of Air-Conducted Ocular Vestibular-Evoked Myogenic Potential.","authors":"Rajesh Kumar Raveendran,Niraj Kumar Singh","doi":"10.1097/aud.0000000000001560","DOIUrl":null,"url":null,"abstract":"OBJECTIVES\r\nThe use of a 500 Hz tone burst over other frequencies was adopted for the clinical recording of ocular vestibular-evoked myogenic potential (oVEMP) on the basis that this stimulus frequency produces larger response amplitudes (frequency tuning) than the other frequencies. However, the possibility of reflex contamination due to a spatially displaced reference electrode from the muscle of the response origin raises questions about using an infraorbital (IO) montage. Nonetheless, the belly-tendon (BT) montage, which places both the recording electrodes over the inferior oblique muscle, increases the chances of obtaining a response with greater contribution from the inferior oblique muscle. However, whether this response continues to show the frequency tuning to 500 Hz is not known. Therefore, the present study aimed to examine the frequency tuning of oVEMP using various electrode montages.\r\n\r\nDESIGN\r\nThirty-eight young adults underwent simultaneous oVEMP recording from IO, BT, chin-referenced, and sternum-referenced electrode montages in response to 250, 500, 750, 1000, 1500, 2000, 3000, and 4000 Hz tone bursts.\r\n\r\nRESULTS\r\nThe frequency tuning most often coincided with a 750-Hz tone burst irrespective of the montage, with the BT montage exhibiting significantly higher response rates and larger peak to peak amplitudes than other montages (p < 0.008). Further, there was a \"substantial\" agreement on frequency tuning between BT and IO montages.\r\n\r\nCONCLUSIONS\r\nWith better response rates and response amplitudes yet similar frequency tuning to the IO montage, the BT montage can be a better option for the clinical recording of oVEMP across frequencies.","PeriodicalId":55172,"journal":{"name":"Ear and Hearing","volume":null,"pages":null},"PeriodicalIF":2.6000,"publicationDate":"2024-08-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ear and Hearing","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/aud.0000000000001560","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
OBJECTIVES
The use of a 500 Hz tone burst over other frequencies was adopted for the clinical recording of ocular vestibular-evoked myogenic potential (oVEMP) on the basis that this stimulus frequency produces larger response amplitudes (frequency tuning) than the other frequencies. However, the possibility of reflex contamination due to a spatially displaced reference electrode from the muscle of the response origin raises questions about using an infraorbital (IO) montage. Nonetheless, the belly-tendon (BT) montage, which places both the recording electrodes over the inferior oblique muscle, increases the chances of obtaining a response with greater contribution from the inferior oblique muscle. However, whether this response continues to show the frequency tuning to 500 Hz is not known. Therefore, the present study aimed to examine the frequency tuning of oVEMP using various electrode montages.
DESIGN
Thirty-eight young adults underwent simultaneous oVEMP recording from IO, BT, chin-referenced, and sternum-referenced electrode montages in response to 250, 500, 750, 1000, 1500, 2000, 3000, and 4000 Hz tone bursts.
RESULTS
The frequency tuning most often coincided with a 750-Hz tone burst irrespective of the montage, with the BT montage exhibiting significantly higher response rates and larger peak to peak amplitudes than other montages (p < 0.008). Further, there was a "substantial" agreement on frequency tuning between BT and IO montages.
CONCLUSIONS
With better response rates and response amplitudes yet similar frequency tuning to the IO montage, the BT montage can be a better option for the clinical recording of oVEMP across frequencies.
期刊介绍:
From the basic science of hearing and balance disorders to auditory electrophysiology to amplification and the psychological factors of hearing loss, Ear and Hearing covers all aspects of auditory and vestibular disorders. This multidisciplinary journal consolidates the various factors that contribute to identification, remediation, and audiologic and vestibular rehabilitation. It is the one journal that serves the diverse interest of all members of this professional community -- otologists, audiologists, educators, and to those involved in the design, manufacture, and distribution of amplification systems. The original articles published in the journal focus on assessment, diagnosis, and management of auditory and vestibular disorders.