The Turkish version of the 5-item Dry Eye Questionnaire (T-DEQ-5): Translation, validity, and reliability

IF 4.1 3区 医学 Q1 OPHTHALMOLOGY Contact Lens & Anterior Eye Pub Date : 2024-09-17 DOI:10.1016/j.clae.2024.102309
Semra Akkaya Turhan , Elif Bagatur Vurgun , Ece Yalçındağ , Samet Gülkaş , Canan Şanal Toprak , Ayşe Ebru Toker
{"title":"The Turkish version of the 5-item Dry Eye Questionnaire (T-DEQ-5): Translation, validity, and reliability","authors":"Semra Akkaya Turhan ,&nbsp;Elif Bagatur Vurgun ,&nbsp;Ece Yalçındağ ,&nbsp;Samet Gülkaş ,&nbsp;Canan Şanal Toprak ,&nbsp;Ayşe Ebru Toker","doi":"10.1016/j.clae.2024.102309","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><div>To evaluate the reliability and validity of Turkish translation of the 5-item Dry Eye Questionnaire (T-DEQ-5) and to compare it with the Ocular Surface Disease Index (OSDI) questionnaire, tear break-up time (TBUT), corneal staining, and Schirmer test results.</div></div><div><h3>Methods</h3><div>The linguistic validation procedures adopted internationally, including forward translations, backward translation into English, examination of the translation quality, and a pilot test on 10 subjects, were employed. The translated and validated questionnaire was applied to 25 subjects two-time points (second time within three days) to evaluate the intra-test reliability. One hundred subjects were recruited for the study. They underwent an ophthalmic examination, including Schirmer tests, TBUT, and ocular surface staining (OSS) after completing OSDI questionnaire. Receiver operating characteristics (ROC) were assessed to determine sensitivity and specificity of the T-DEQ-5.</div></div><div><h3>Results</h3><div>The mean age of subjects was 45.7 ± 16.2 years, with 65 % being female. Overall, the test–retest reliability was excellent with an intra-class correlation coefficient value of 0.95 (95 % CI 0.90–0.98, p &lt; 0.001). The Cronbach’s alpha reliability coefficient was 0.90, which demonstrated a strong level of internal consistency of the T-DEQ-5. Using ROC analysis to compare the results of the T-DEQ-5 with those of the OSDI, the area under the curve was found 0.95, with an optimal cut-off threshold of 6, resulting in 81 % sensitivity and 91 % specificity. Establishing the diagnosis based on a positive OSDI (≥13) and at least one positive sign (TBUT and/or OSS) yielded a sensitivity of 95 % and a specificity of 87 % at the cut-off threshold of 6.</div></div><div><h3>Conclusion</h3><div>The Turkish version of the DEQ-5 is a valid and reliable questionnaire and capable of differentiating patients with dry eye.</div></div>","PeriodicalId":49087,"journal":{"name":"Contact Lens & Anterior Eye","volume":"47 6","pages":"Article 102309"},"PeriodicalIF":4.1000,"publicationDate":"2024-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Contact Lens & Anterior Eye","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1367048424002029","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

To evaluate the reliability and validity of Turkish translation of the 5-item Dry Eye Questionnaire (T-DEQ-5) and to compare it with the Ocular Surface Disease Index (OSDI) questionnaire, tear break-up time (TBUT), corneal staining, and Schirmer test results.

Methods

The linguistic validation procedures adopted internationally, including forward translations, backward translation into English, examination of the translation quality, and a pilot test on 10 subjects, were employed. The translated and validated questionnaire was applied to 25 subjects two-time points (second time within three days) to evaluate the intra-test reliability. One hundred subjects were recruited for the study. They underwent an ophthalmic examination, including Schirmer tests, TBUT, and ocular surface staining (OSS) after completing OSDI questionnaire. Receiver operating characteristics (ROC) were assessed to determine sensitivity and specificity of the T-DEQ-5.

Results

The mean age of subjects was 45.7 ± 16.2 years, with 65 % being female. Overall, the test–retest reliability was excellent with an intra-class correlation coefficient value of 0.95 (95 % CI 0.90–0.98, p < 0.001). The Cronbach’s alpha reliability coefficient was 0.90, which demonstrated a strong level of internal consistency of the T-DEQ-5. Using ROC analysis to compare the results of the T-DEQ-5 with those of the OSDI, the area under the curve was found 0.95, with an optimal cut-off threshold of 6, resulting in 81 % sensitivity and 91 % specificity. Establishing the diagnosis based on a positive OSDI (≥13) and at least one positive sign (TBUT and/or OSS) yielded a sensitivity of 95 % and a specificity of 87 % at the cut-off threshold of 6.

Conclusion

The Turkish version of the DEQ-5 is a valid and reliable questionnaire and capable of differentiating patients with dry eye.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
土耳其版 5 项干眼症问卷(T-DEQ-5):翻译、有效性和可靠性。
目的评估土耳其语翻译的 5 项干眼症问卷(T-DEQ-5)的可靠性和有效性,并将其与眼表疾病指数(OSDI)问卷、泪液破裂时间(TBUT)、角膜染色和 Schirmer 测试结果进行比较。方法采用国际通用的语言验证程序,包括正译、反译成英语、检查翻译质量和对 10 名受试者进行试点测试。翻译和验证后的问卷对 25 名受试者进行了两次测试(第二次测试在三天内进行),以评估测试内信度。研究共招募了 100 名受试者。他们在填写 OSDI 问卷后接受了眼科检查,包括施尔默试验、TBUT 和眼表染色(OSS)。结果受试者的平均年龄为(45.7 ± 16.2)岁,其中 65% 为女性。总体而言,测试-重复测试的可靠性极佳,类内相关系数为 0.95 (95 % CI 0.90-0.98, p < 0.001)。Cronbach's阿尔法信度系数为0.90,表明T-DEQ-5具有很强的内部一致性。通过 ROC 分析比较 T-DEQ-5 和 OSDI 的结果,发现曲线下面积为 0.95,最佳临界值为 6,灵敏度为 81%,特异度为 91%。根据 OSDI 阳性(≥13)和至少一个阳性体征(TBUT 和/或 OSS)进行诊断,在 6 的临界值下,灵敏度为 95%,特异度为 87%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
7.60
自引率
18.80%
发文量
198
审稿时长
55 days
期刊介绍: Contact Lens & Anterior Eye is a research-based journal covering all aspects of contact lens theory and practice, including original articles on invention and innovations, as well as the regular features of: Case Reports; Literary Reviews; Editorials; Instrumentation and Techniques and Dates of Professional Meetings.
期刊最新文献
Validation and repeatability assessment of the Chinese version of the Ocular Surface Disease Index (OSDI), 5-item dry eye (DEQ-5), and contact lens dry eye questionnaire-8 (CLDEQ-8) questionnaires. Artificial intelligence-assisted fitting method using corneal topography outcomes enhances success rate in orthokeratology lens fitting. Randomised controlled trial on effects of topical insulin compared to artificial tears and normal saline on tear inflammatory mediator levels and clinical parameters in diabetics with dry eye disease. Development and evaluation of ocular antibiotic-loaded soluble film inserts. Digital eye strain and clinical correlates in older adults.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1