Sofie Tilborghs,Tiffany Liang,Stavroula Raptis,Ayako Ishikita,Werner Budts,Tom Dresselaers,Jan Bogaert,Frederik Maes,Rachel M Wald,Alexander Van De Bruaene
{"title":"Automated biventricular quantification in patients with repaired tetralogy of Fallot using a 3D deep learning segmentation model.","authors":"Sofie Tilborghs,Tiffany Liang,Stavroula Raptis,Ayako Ishikita,Werner Budts,Tom Dresselaers,Jan Bogaert,Frederik Maes,Rachel M Wald,Alexander Van De Bruaene","doi":"10.1016/j.jocmr.2024.101092","DOIUrl":null,"url":null,"abstract":"BACKGROUND\r\nDeep learning is the state-of-the-art approach for automated segmentation of the left ventricle (LV) and right ventricle (RV) in cardiac magnetic resonance (CMR) images. However, these models have been mostly trained and validated using CMR datasets of structurally normal hearts or cases with acquired cardiac disease, and are therefore not well-suited to handle cases with congenital cardiac disease such as tetralogy of Fallot (TOF). We aimed to develop and validate a dedicated model with improved performance for LV and RV cavity and myocardium quantification in patients with repaired TOF.\r\n\r\nMETHODS\r\nWe trained a 3D convolutional neural network (CNN) with 5-fold cross-validation using manually delineated end-diastolic (ED) and end-systolic (ES) short-axis image stacks obtained from either a public dataset containing patients with no or acquired cardiac pathology (n=100), an institutional dataset of TOF patients (n=96), or both datasets mixed. Our method allows for missing labels in the training images to accommodate for different ED and ES phases for LV and RV as is commonly the case in TOF. The best performing model was applied to all frames of a separate test set of TOF cases (n=36) and ED and ES phases were automatically determined for LV and RV separately. The model was evaluated against the performance of a commercial software (suiteHEART®, NeoSoft, Pewaukee, Wisconsin, US).\r\n\r\nRESULTS\r\nTraining on the mixture of both datasets yielded the best agreement with the manual ground truth for the TOF cases, achieving a median DICE similarity coefficient of (93.8%, 89.8%) for LV cavity and of (92.9%, 90.9%) for RV cavity at (ED, ES) respectively, and of 80.9% and 61.8% for LV and RV myocardium at ED. The offset in automated ED and ES frame selection was 0.56 and 0.89 frames on average for LV and RV respectively. No statistically significant differences were found between our model and the commercial software for LV quantification (two-sided Wilcoxon signed rank test, p<5%), while RV quantification was significantly improved with our model achieving a mean absolute error of 12ml for RV cavity compared to 36ml for the commercial software.\r\n\r\nCONCLUSION\r\nWe developed and validated a fully automatic segmentation and quantification approach for LV and RV, including RV mass, in patients with repaired TOF. Compared to a commercial software, our approach is superior for RV quantification indicating its potential in clinical practice.","PeriodicalId":15221,"journal":{"name":"Journal of Cardiovascular Magnetic Resonance","volume":"64 1","pages":"101092"},"PeriodicalIF":4.2000,"publicationDate":"2024-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Magnetic Resonance","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jocmr.2024.101092","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
BACKGROUND
Deep learning is the state-of-the-art approach for automated segmentation of the left ventricle (LV) and right ventricle (RV) in cardiac magnetic resonance (CMR) images. However, these models have been mostly trained and validated using CMR datasets of structurally normal hearts or cases with acquired cardiac disease, and are therefore not well-suited to handle cases with congenital cardiac disease such as tetralogy of Fallot (TOF). We aimed to develop and validate a dedicated model with improved performance for LV and RV cavity and myocardium quantification in patients with repaired TOF.
METHODS
We trained a 3D convolutional neural network (CNN) with 5-fold cross-validation using manually delineated end-diastolic (ED) and end-systolic (ES) short-axis image stacks obtained from either a public dataset containing patients with no or acquired cardiac pathology (n=100), an institutional dataset of TOF patients (n=96), or both datasets mixed. Our method allows for missing labels in the training images to accommodate for different ED and ES phases for LV and RV as is commonly the case in TOF. The best performing model was applied to all frames of a separate test set of TOF cases (n=36) and ED and ES phases were automatically determined for LV and RV separately. The model was evaluated against the performance of a commercial software (suiteHEART®, NeoSoft, Pewaukee, Wisconsin, US).
RESULTS
Training on the mixture of both datasets yielded the best agreement with the manual ground truth for the TOF cases, achieving a median DICE similarity coefficient of (93.8%, 89.8%) for LV cavity and of (92.9%, 90.9%) for RV cavity at (ED, ES) respectively, and of 80.9% and 61.8% for LV and RV myocardium at ED. The offset in automated ED and ES frame selection was 0.56 and 0.89 frames on average for LV and RV respectively. No statistically significant differences were found between our model and the commercial software for LV quantification (two-sided Wilcoxon signed rank test, p<5%), while RV quantification was significantly improved with our model achieving a mean absolute error of 12ml for RV cavity compared to 36ml for the commercial software.
CONCLUSION
We developed and validated a fully automatic segmentation and quantification approach for LV and RV, including RV mass, in patients with repaired TOF. Compared to a commercial software, our approach is superior for RV quantification indicating its potential in clinical practice.
期刊介绍:
Journal of Cardiovascular Magnetic Resonance (JCMR) publishes high-quality articles on all aspects of basic, translational and clinical research on the design, development, manufacture, and evaluation of cardiovascular magnetic resonance (CMR) methods applied to the cardiovascular system. Topical areas include, but are not limited to:
New applications of magnetic resonance to improve the diagnostic strategies, risk stratification, characterization and management of diseases affecting the cardiovascular system.
New methods to enhance or accelerate image acquisition and data analysis.
Results of multicenter, or larger single-center studies that provide insight into the utility of CMR.
Basic biological perceptions derived by CMR methods.