Dan Gordon , Justin M. Cardenas , David Fawley , Kurt J. Kitziger , Brian P. Gladnick
{"title":"Mitigating calcar fracture risk with automated impaction during total hip arthroplasty","authors":"Dan Gordon , Justin M. Cardenas , David Fawley , Kurt J. Kitziger , Brian P. Gladnick","doi":"10.1016/j.jor.2024.08.002","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Automated broaching has recently been introduced for total hip arthroplasty (THA), with the goal of improving surgical efficiency and reducing surgeon workload. While studies have suggested that this technique may improve femoral sizing and alignment, little has been published regarding its safety, particularly with regard to calcar fractures. The purpose of our study was to evaluate the risk of calcar fracture during automated broaching, and to determine if this risk can be mitigated.</p></div><div><h3>Methods</h3><p>We queried our prospective institutional database and identified 1596 unilateral THAs performed by the senior author using automated impaction between 2019 and 2023. We identified the incidence of calcar fracture with automated impaction, and whether the fracture occurred during broaching or stem insertion. We additionally determined calcar fracture incidence within two consecutive subgroups of patients using different stem insertion techniques; subgroup (1): automated broaching with automated stem insertion for all patients; versus subgroup (2): automated broaching with automated stem insertion ONLY if a cushion of cancellous bone separated the broach from the calcar, otherwise the stem was placed manually. Continuous and categorical variables were analyzed with Student's t-test and Fisher's exact test, respectively.</p></div><div><h3>Results</h3><p>Seventeen calcar fractures occurred intraoperatively (1.1 %). Only two fractures occurred during automated broaching (0.1 %), while fifteen occurred during final stem impaction (0.9 %) (p = 0.007). Four calcar fractures (1.4 %) occurred in subgroup 1, compared to two in subgroup 2 (0.6 %) (p = 0.28).</p></div><div><h3>Conclusions</h3><p>Our study found a calcar fracture incidence of 1.1 % using automated impaction, consistent with historically reported rates of 0.4–3.7 %. We found that calcar fractures are more likely to occur during stem insertion than during femoral broaching. We recommend that if any part of the final broach is in direct contact with the calcar, the final stem should be impacted manually to minimize fracture risk.</p></div>","PeriodicalId":16633,"journal":{"name":"Journal of orthopaedics","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2024-08-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0972978X24002903/pdfft?md5=e35f0247e7cdda1e88b8bbf65030d0e6&pid=1-s2.0-S0972978X24002903-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of orthopaedics","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0972978X24002903","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Background
Automated broaching has recently been introduced for total hip arthroplasty (THA), with the goal of improving surgical efficiency and reducing surgeon workload. While studies have suggested that this technique may improve femoral sizing and alignment, little has been published regarding its safety, particularly with regard to calcar fractures. The purpose of our study was to evaluate the risk of calcar fracture during automated broaching, and to determine if this risk can be mitigated.
Methods
We queried our prospective institutional database and identified 1596 unilateral THAs performed by the senior author using automated impaction between 2019 and 2023. We identified the incidence of calcar fracture with automated impaction, and whether the fracture occurred during broaching or stem insertion. We additionally determined calcar fracture incidence within two consecutive subgroups of patients using different stem insertion techniques; subgroup (1): automated broaching with automated stem insertion for all patients; versus subgroup (2): automated broaching with automated stem insertion ONLY if a cushion of cancellous bone separated the broach from the calcar, otherwise the stem was placed manually. Continuous and categorical variables were analyzed with Student's t-test and Fisher's exact test, respectively.
Results
Seventeen calcar fractures occurred intraoperatively (1.1 %). Only two fractures occurred during automated broaching (0.1 %), while fifteen occurred during final stem impaction (0.9 %) (p = 0.007). Four calcar fractures (1.4 %) occurred in subgroup 1, compared to two in subgroup 2 (0.6 %) (p = 0.28).
Conclusions
Our study found a calcar fracture incidence of 1.1 % using automated impaction, consistent with historically reported rates of 0.4–3.7 %. We found that calcar fractures are more likely to occur during stem insertion than during femoral broaching. We recommend that if any part of the final broach is in direct contact with the calcar, the final stem should be impacted manually to minimize fracture risk.
期刊介绍:
Journal of Orthopaedics aims to be a leading journal in orthopaedics and contribute towards the improvement of quality of orthopedic health care. The journal publishes original research work and review articles related to different aspects of orthopaedics including Arthroplasty, Arthroscopy, Sports Medicine, Trauma, Spine and Spinal deformities, Pediatric orthopaedics, limb reconstruction procedures, hand surgery, and orthopaedic oncology. It also publishes articles on continuing education, health-related information, case reports and letters to the editor. It is requested to note that the journal has an international readership and all submissions should be aimed at specifying something about the setting in which the work was conducted. Authors must also provide any specific reasons for the research and also provide an elaborate description of the results.