Theoretical screening and electrochemical sensor for determination of norepinephrine using a molecularly imprinted poly (3-amiophenylboronic acid)

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2024-09-20 DOI:10.1016/j.ab.2024.115676
Karthikeyan Murugesan , Marimuthu Dhinesh Kumar , Ganesan Kaniraja , Periyasamy Ananthappan , Vairathevar Sivasamy Vasantha , Chandran Karunakaran
{"title":"Theoretical screening and electrochemical sensor for determination of norepinephrine using a molecularly imprinted poly (3-amiophenylboronic acid)","authors":"Karthikeyan Murugesan ,&nbsp;Marimuthu Dhinesh Kumar ,&nbsp;Ganesan Kaniraja ,&nbsp;Periyasamy Ananthappan ,&nbsp;Vairathevar Sivasamy Vasantha ,&nbsp;Chandran Karunakaran","doi":"10.1016/j.ab.2024.115676","DOIUrl":null,"url":null,"abstract":"<div><div>Norepinephrine (NE) is the primary catecholamine (CA) of interest in the medical field, as it plays a key role in regulating the hormonal and neurological systems. Some NE concentration dysfunction can lead to a number of serious physical conditions. As a result, quick and sensitive NE detection is most critical in medical technology. Thus, in this research, a molecularly imprinted polymer (MIP) was used to create an electrochemical sensor for the selective detection of NE. Prior to this, functional monomers were chosen through molecular modeling utilizing molecular mechanics and quantum mechanics computations. According to these studies, the 3-aminophenylboronic acid (3-APBA) functional monomer produces the most stable complex with NE in molecular modeling calculations. Based on this, by electropolymerizing 3-APBA in the presence of the template molecule NE, an imprinting polymer film is formed on the screen-printed carbon electrode (SPCE) surface. Stepwise fabrication of imprinted polymer films was examined through differential pulse voltammetry (DPV), cyclic voltammetry (CV), scanning electron microscopy (SEM), and electrochemical impedance spectroscopy (EIS). The performance of the electrochemical NE sensor removal and rebinding levels of the template was studied and optimized. The selectivity for NE was confirmed by using interference studies of small molecules like dopamine, tyrosine, and serotonin. Under optimum levels, the fabricated MIP sensor had a broad linear range over NE concentrations of 0.1 pM–5 pM; sensitivity: 0.004 mA pM<sup>−1</sup>; limit of detection: 0.03 pM. It is noteworthy that the newly created MIP sensor was effectively validated for NE detection in plasma samples.</div></div>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"99","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0003269724002203","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

Abstract

Norepinephrine (NE) is the primary catecholamine (CA) of interest in the medical field, as it plays a key role in regulating the hormonal and neurological systems. Some NE concentration dysfunction can lead to a number of serious physical conditions. As a result, quick and sensitive NE detection is most critical in medical technology. Thus, in this research, a molecularly imprinted polymer (MIP) was used to create an electrochemical sensor for the selective detection of NE. Prior to this, functional monomers were chosen through molecular modeling utilizing molecular mechanics and quantum mechanics computations. According to these studies, the 3-aminophenylboronic acid (3-APBA) functional monomer produces the most stable complex with NE in molecular modeling calculations. Based on this, by electropolymerizing 3-APBA in the presence of the template molecule NE, an imprinting polymer film is formed on the screen-printed carbon electrode (SPCE) surface. Stepwise fabrication of imprinted polymer films was examined through differential pulse voltammetry (DPV), cyclic voltammetry (CV), scanning electron microscopy (SEM), and electrochemical impedance spectroscopy (EIS). The performance of the electrochemical NE sensor removal and rebinding levels of the template was studied and optimized. The selectivity for NE was confirmed by using interference studies of small molecules like dopamine, tyrosine, and serotonin. Under optimum levels, the fabricated MIP sensor had a broad linear range over NE concentrations of 0.1 pM–5 pM; sensitivity: 0.004 mA pM−1; limit of detection: 0.03 pM. It is noteworthy that the newly created MIP sensor was effectively validated for NE detection in plasma samples.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用分子印迹聚(3-氨基苯硼酸)测定去甲肾上腺素的理论筛选和电化学传感器。
去甲肾上腺素(NE)是医学领域关注的主要儿茶酚胺(CA),因为它在调节荷尔蒙和神经系统方面发挥着关键作用。某些 NE 浓度失调会导致一些严重的身体状况。因此,快速灵敏地检测 NE 在医疗技术中至关重要。因此,在这项研究中,使用分子印迹聚合物(MIP)创建了一种选择性检测 NE 的电化学传感器。在此之前,利用分子力学和量子力学计算,通过分子建模选择了功能单体。根据这些研究,在分子建模计算中,3-氨基苯硼酸(3-APBA)功能单体与 NE 产生的复合物最为稳定。在此基础上,通过在模板分子 NE 存在下对 3-APBA 进行电聚合,在丝网印刷碳电极(SPCE)表面形成压印聚合物薄膜。研究人员通过差分脉冲伏安法(DPV)、循环伏安法(CV)、扫描电子显微镜(SEM)和电化学阻抗谱(EIS)对印迹聚合物薄膜的逐步制备过程进行了检验。研究并优化了电化学 NE 传感器的去除性能和模板的再结合水平。通过对多巴胺、酪氨酸和血清素等小分子的干扰研究,证实了 NE 的选择性。在最佳水平下,所制造的 MIP 传感器在 0.1 pM 至 5 pM 的 NE 浓度范围内具有较宽的线性范围;灵敏度:0.004 mA pM-1;检测限:0.03 pM:0.03 pM。值得注意的是,新制作的 MIP 传感器在检测血浆样品中的 NE 方面得到了有效验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1