Changes in Corticospinal Tract Consistency after Dry Needling in a Stroke Patient.

IF 0.9 Q4 CLINICAL NEUROLOGY Case Reports in Neurological Medicine Pub Date : 2024-09-14 eCollection Date: 2024-01-01 DOI:10.1155/2024/5115313
Masoome Ebrahimzadeh, Noureddin Nakhostin Ansari, Iraj Abdollahi, Behnam Akhbari, Jan Dommerholt
{"title":"Changes in Corticospinal Tract Consistency after Dry Needling in a Stroke Patient.","authors":"Masoome Ebrahimzadeh, Noureddin Nakhostin Ansari, Iraj Abdollahi, Behnam Akhbari, Jan Dommerholt","doi":"10.1155/2024/5115313","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Dry needling (DN) is a technique employed to mitigate spasticity and enhance functionality in stroke patients. We report the impact of DN on both corticospinal tract (CST) consistency and wrist flexors spasticity of an individual affected by stroke.</p><p><strong>Case: </strong>The participant was a 57-year-old male who had experienced an ischemic stroke 9 months prior. The primary outcome measures included fractional anisotropy (FA), asymmetry FA (aFA), ratio FA (rFA), and Modified Modified Ashworth Scale (MMAS). Additionally, secondary outcomes encompassed wrist extension range of motion (ROM) and performance in the box and block test (BBT). These measurements were taken both before and after the administration of DN treatment.</p><p><strong>Results: </strong>After the application of DN, the mean FA of the ipsilesional CST increased from 0.35 to 0.39, concomitantly with a decline in aFA from 0.18 to 0.13. Notably, the rFA exhibited a pre-DN value of 0.69, which subsequently rose to 0.76 post-DN. Moreover, a significant reduction in MMAS scores was detected, from a score of \"3\" prior to DN application to a post-DN score of \"1\". In terms of wrist mobility, both active and passive extension ROM exhibited favorable improvements, with an increase of 12° for active extension and 16° for passive extension. Furthermore, there was a substantial improvement in the BBT score, an indicator of manual dexterity, ascending from 12 to 24.</p><p><strong>Conclusion: </strong>Enhancements in CST consistency suggest it as a potential mechanism contributing to the observed improvements following DN in this stroke case.</p>","PeriodicalId":9615,"journal":{"name":"Case Reports in Neurological Medicine","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2024-09-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11416164/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Case Reports in Neurological Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2024/5115313","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Dry needling (DN) is a technique employed to mitigate spasticity and enhance functionality in stroke patients. We report the impact of DN on both corticospinal tract (CST) consistency and wrist flexors spasticity of an individual affected by stroke.

Case: The participant was a 57-year-old male who had experienced an ischemic stroke 9 months prior. The primary outcome measures included fractional anisotropy (FA), asymmetry FA (aFA), ratio FA (rFA), and Modified Modified Ashworth Scale (MMAS). Additionally, secondary outcomes encompassed wrist extension range of motion (ROM) and performance in the box and block test (BBT). These measurements were taken both before and after the administration of DN treatment.

Results: After the application of DN, the mean FA of the ipsilesional CST increased from 0.35 to 0.39, concomitantly with a decline in aFA from 0.18 to 0.13. Notably, the rFA exhibited a pre-DN value of 0.69, which subsequently rose to 0.76 post-DN. Moreover, a significant reduction in MMAS scores was detected, from a score of "3" prior to DN application to a post-DN score of "1". In terms of wrist mobility, both active and passive extension ROM exhibited favorable improvements, with an increase of 12° for active extension and 16° for passive extension. Furthermore, there was a substantial improvement in the BBT score, an indicator of manual dexterity, ascending from 12 to 24.

Conclusion: Enhancements in CST consistency suggest it as a potential mechanism contributing to the observed improvements following DN in this stroke case.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
中风患者干针治疗后皮质脊髓束一致性的变化
背景:干针疗法(DN)是一种用于缓解中风患者痉挛和增强其功能的技术。我们报告了干针疗法对中风患者皮质脊髓束(CST)一致性和腕屈肌痉挛的影响。主要结果指标包括分数各向异性(FA)、不对称FA(aFA)、比率FA(rFA)和改良改良阿什沃斯量表(MMAS)。此外,次要结果还包括腕关节伸展活动范围(ROM)和箱形阻滞试验(BBT)的表现。这些测量均在使用 DN 治疗前后进行:结果:使用 DN 后,CST 同侧的平均 FA 值从 0.35 增至 0.39,同时 aFA 值从 0.18 降至 0.13。值得注意的是,rFA 在 DN 前为 0.69,DN 后上升至 0.76。此外,MMAS 评分也明显下降,从使用 DN 前的 "3 "分降至 DN 后的 "1 "分。在腕关节活动度方面,主动和被动伸展活动度均有良好改善,主动伸展活动度增加了 12°,被动伸展活动度增加了 16°。此外,作为手部灵活性指标的 BBT 评分也有大幅提高,从 12 分提高到 24 分:结论:CST一致性的增强表明,它是在该中风病例中观察到的 DN 后病情改善的潜在机制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
26
审稿时长
11 weeks
期刊最新文献
Disseminated Intracranial and Spinal Neurenteric Cysts: A Case Report and Literature Review. New-Onset Focal to Bilateral Tonic-Clonic Seizure Following COVID-19 Vaccination. Endotracheal Oxygen Insufflation Associated with Life-Threatening Barotrauma during Apnea Testing. Severe Neurotoxicity due to Atropa belladonna Poisoning: A Case Report and Literature Review. Rhabdomyolysis Induced by Levetiracetam: A Case Report in Kuwait.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1