Chemical and physical properties of radiopaque Portland cement formulation with reduced particle size.

IF 1.9 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE Dental materials journal Pub Date : 2024-09-28 Epub Date: 2024-09-10 DOI:10.4012/dmj.2024-015
Hoda Mohamed Elnawawy, Muralithran Govindan Kutty, Noor Azlin Yahya, Noor Hayaty Abu Kasim, Paul Roy Cooper, Josette Camilleri, Hany Mohamed Aly Ahmed
{"title":"Chemical and physical properties of radiopaque Portland cement formulation with reduced particle size.","authors":"Hoda Mohamed Elnawawy, Muralithran Govindan Kutty, Noor Azlin Yahya, Noor Hayaty Abu Kasim, Paul Roy Cooper, Josette Camilleri, Hany Mohamed Aly Ahmed","doi":"10.4012/dmj.2024-015","DOIUrl":null,"url":null,"abstract":"<p><p>This study compared the chemical and physical properties of an experimental radiopaque white Portland cement (REPC) with reduced particle size to ProRoot white mineral trioxide aggregate (WMTA). The particle size distribution of experimental Portland cement (EPC) was examined, and then nano-zirconium oxide (nano-ZrO) was added to produce REPC. Chemical analysis, initial setting time, pH values, and push-out bond strength were evaluated. Results showed that REPC had smallest particle size (354.5±26.45 nm), while PC had the largest (1,309.67±60.54 nm) (p<0.05). Differences in chemical composition were observed. REPC exhibited shorter setting time (32.7±0.58 min) compared to WMTA (131.67±2.89 min) and PC (163.33±2.89 min) (p<0.05). All groups showed alkaline pH (p<0.05). REPC demonstrated the highest push-out bond strength (22.24±4.33 MPa) compared with WMTA (15.53±3.26 MPa) and PC (16.8±5.43 MPa) (p<0.05). This cost-effective PC formulation reduced the setting time and increased the push-out bond strength while maintaining the alkaline properties of the original cements.</p>","PeriodicalId":11065,"journal":{"name":"Dental materials journal","volume":" ","pages":"672-682"},"PeriodicalIF":1.9000,"publicationDate":"2024-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dental materials journal","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.4012/dmj.2024-015","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/10 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

This study compared the chemical and physical properties of an experimental radiopaque white Portland cement (REPC) with reduced particle size to ProRoot white mineral trioxide aggregate (WMTA). The particle size distribution of experimental Portland cement (EPC) was examined, and then nano-zirconium oxide (nano-ZrO) was added to produce REPC. Chemical analysis, initial setting time, pH values, and push-out bond strength were evaluated. Results showed that REPC had smallest particle size (354.5±26.45 nm), while PC had the largest (1,309.67±60.54 nm) (p<0.05). Differences in chemical composition were observed. REPC exhibited shorter setting time (32.7±0.58 min) compared to WMTA (131.67±2.89 min) and PC (163.33±2.89 min) (p<0.05). All groups showed alkaline pH (p<0.05). REPC demonstrated the highest push-out bond strength (22.24±4.33 MPa) compared with WMTA (15.53±3.26 MPa) and PC (16.8±5.43 MPa) (p<0.05). This cost-effective PC formulation reduced the setting time and increased the push-out bond strength while maintaining the alkaline properties of the original cements.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
粒径减小的不透射线硅酸盐水泥配方的化学和物理特性。
本研究比较了粒径减小的不透射线白色硅酸盐水泥(REPC)与 ProRoot 三氧化二铝白色矿物骨料(WMTA)的化学和物理特性。研究人员检测了实验波特兰水泥(EPC)的粒度分布,然后添加纳米氧化锆(nano-ZrO)生产 REPC。对化学分析、初凝时间、pH 值和推出粘接强度进行了评估。结果表明,REPC 的粒径最小(354.5±26.45 nm),而 PC 的粒径最大(1,309.67±60.54 nm)(p<0.05)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Dental materials journal
Dental materials journal 医学-材料科学:生物材料
CiteScore
4.60
自引率
4.00%
发文量
102
审稿时长
3 months
期刊介绍: Dental Materials Journal is a peer review journal published by the Japanese Society for Dental Materials and Devises aiming to introduce the progress of the basic and applied sciences in dental materials and biomaterials. The dental materials-related clinical science and instrumental technologies are also within the scope of this journal. The materials dealt include synthetic polymers, ceramics, metals and tissue-derived biomaterials. Forefront dental materials and biomaterials used in developing filed, such as tissue engineering, bioengineering and artificial intelligence, are positively considered for the review as well. Recent acceptance rate of the submitted manuscript in the journal is around 30%.
期刊最新文献
Effects of repetitive insertion/removal and occlusal load on the retentive force of rest plate-I bar clasps made by selective laser melting. Shape reproducibility of retentive devices made of cast titanium. Bond strength of 4META-MMA-TBB resin to a CAD/CAM composite resin block and analysis of acetone-insoluble cured resin residues at adhesive interfaces. Effect of rosmarinic acid on microtensile bond strength of 1-step self-etch adhesive on artificial caries-affected dentine with or without NaOCl treatment: An in-vitro study. Rheological properties and handling characteristics of four injectable calcium hydroxide pastes.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1