Accuracy of an autonomous dental implant robotic system in placing tilted implants for edentulous arches.

IF 4.3 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Prosthetic Dentistry Pub Date : 2024-09-19 DOI:10.1016/j.prosdent.2024.07.032
Shuang Xi, Jun Hu, Guangna Yue, Shaohai Wang
{"title":"Accuracy of an autonomous dental implant robotic system in placing tilted implants for edentulous arches.","authors":"Shuang Xi, Jun Hu, Guangna Yue, Shaohai Wang","doi":"10.1016/j.prosdent.2024.07.032","DOIUrl":null,"url":null,"abstract":"<p><strong>Statement of problem: </strong>Accurate placement of tilted implants is essential as they are typically close to important anatomic structures. Inaccurate implant position may damage those structures and affect outcomes.</p><p><strong>Purpose: </strong>The purpose of this in vitro study was to compare the accuracy and efficiency of an autonomous dental implant robotic (ADIR) system and a static computer-assisted implant surgery (sCAIS) system in placing tilted implants in edentulous patients.</p><p><strong>Material and methods: </strong>Ten 3-dimensionally (3D) printed edentulous mandibular casts were assigned to 1 of 2 groups (ADIR and sCAIS). The coronal, apical, and angular deviations of the placement of tilted implants, preoperative preparation time, and surgical time were compared between the 2 groups. The paired samples t test and the independent samples t test were used to compare the groups (α=.05).</p><p><strong>Results: </strong>The mean ±standard deviation of coronal, apical, and angular deviation in the ADIR group and sCAIS group were 0.47 ±0.06 mm versus 1.09 ±0.11 mm, 0.47 ±0.05 mm versus 1.53 ±0.14 mm, and 0.91 ±0.82 degrees versus 2.83 ±0.55 degrees, respectively. The deviations of the tilted implant positions in the ADIR were relatively small and significantly different from those of sCAIS (P<.05). The preoperative preparation time of the ADIR group was significantly longer than that of the sCAIS group (P<.001), and the surgical time for the 2 groups was statistically similar (P=.259).</p><p><strong>Conclusions: </strong>Compared with the sCAIS system, the deviation of tilted implants in the ADIR group was smaller, but the preoperative preparation time was longer. The results indicated that using the ADIR for tilted implantation can lead to more accurate implantation positions and reduce the occurrence of complications. However, it is time consuming, and the workflow should be simplified to improve efficiency.</p>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2024-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.prosdent.2024.07.032","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Statement of problem: Accurate placement of tilted implants is essential as they are typically close to important anatomic structures. Inaccurate implant position may damage those structures and affect outcomes.

Purpose: The purpose of this in vitro study was to compare the accuracy and efficiency of an autonomous dental implant robotic (ADIR) system and a static computer-assisted implant surgery (sCAIS) system in placing tilted implants in edentulous patients.

Material and methods: Ten 3-dimensionally (3D) printed edentulous mandibular casts were assigned to 1 of 2 groups (ADIR and sCAIS). The coronal, apical, and angular deviations of the placement of tilted implants, preoperative preparation time, and surgical time were compared between the 2 groups. The paired samples t test and the independent samples t test were used to compare the groups (α=.05).

Results: The mean ±standard deviation of coronal, apical, and angular deviation in the ADIR group and sCAIS group were 0.47 ±0.06 mm versus 1.09 ±0.11 mm, 0.47 ±0.05 mm versus 1.53 ±0.14 mm, and 0.91 ±0.82 degrees versus 2.83 ±0.55 degrees, respectively. The deviations of the tilted implant positions in the ADIR were relatively small and significantly different from those of sCAIS (P<.05). The preoperative preparation time of the ADIR group was significantly longer than that of the sCAIS group (P<.001), and the surgical time for the 2 groups was statistically similar (P=.259).

Conclusions: Compared with the sCAIS system, the deviation of tilted implants in the ADIR group was smaller, but the preoperative preparation time was longer. The results indicated that using the ADIR for tilted implantation can lead to more accurate implantation positions and reduce the occurrence of complications. However, it is time consuming, and the workflow should be simplified to improve efficiency.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
自主牙科植入机器人系统在为无牙弓植入倾斜植入体时的准确性。
问题陈述:倾斜种植体通常靠近重要的解剖结构,因此准确植入至关重要。目的:本体外研究的目的是比较自主牙科种植机器人(ADIR)系统和静态计算机辅助种植手术(sCAIS)系统在无牙颌患者中植入倾斜种植体的准确性和效率:将 10 个三维打印的无牙下颌模型分成两组(ADIR 和 sCAIS)。比较两组间倾斜种植体植入的冠状偏差、根尖偏差和角度偏差、术前准备时间和手术时间。两组间的比较采用配对样本 t 检验和独立样本 t 检验(α=.05):ADIR组和sCAIS组的冠状偏差、根尖偏差和角度偏差的平均值(±标准偏差)分别为0.47±0.06毫米对1.09±0.11毫米,0.47±0.05毫米对1.53±0.14毫米,0.91±0.82度对2.83±0.55度。ADIR 中倾斜种植体位置的偏差相对较小,与 sCAIS 中的偏差显著不同(PConclusions:与 sCAIS 系统相比,ADIR 组倾斜种植体的偏差较小,但术前准备时间较长。结果表明,使用 ADIR 进行倾斜种植可以获得更准确的种植体位置,减少并发症的发生。但该方法耗时较长,应简化工作流程以提高效率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry 医学-牙科与口腔外科
CiteScore
7.00
自引率
13.00%
发文量
599
审稿时长
69 days
期刊介绍: The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.
期刊最新文献
Effect of machining method and margin design on the accuracy and margin quality of monolithic zirconia crowns. A digital workflow for recording implant positions and jaw relation for implant-supported complete arch prostheses. Annual review of selected scientific literature: A report of the Committee on Scientific Investigation of the American Academy of Restorative Dentistry. Prosthodontic rehabilitation of a patient after mucormycosis using a digitally fabricated hollow complete denture with 3D printed intramucosal inserts. Unconventional digital dentures: Overcoming software challenges and integrating digital workflows into conventional techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1