Incidence of medical device-related pressure injuries and identification of risk factors in the neonatal unit.

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2024-09-17 DOI:10.1016/j.jtv.2024.09.005
Zalihe Yarkıner, Arzu Bahar, Münevver Sönmez, Emine Kapan, Simge Şahin, Ezgi Köstekçi, Ömer Erdeve
{"title":"Incidence of medical device-related pressure injuries and identification of risk factors in the neonatal unit.","authors":"Zalihe Yarkıner, Arzu Bahar, Münevver Sönmez, Emine Kapan, Simge Şahin, Ezgi Köstekçi, Ömer Erdeve","doi":"10.1016/j.jtv.2024.09.005","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>This study was conducted to investigate the incidence of medical device-related pressure injuries (MDRPIs) and the risk factors influencing their occurrence in the neonatal intensive care unit (NICU).</p><p><strong>Method: </strong>This study is a prospective, descriptive study. The research was conducted with 116 newborns between June 1, 2022, and June 1, 2023. Newborns who stayed in the neonatal intensive care unit for at least 24 h were observed daily for medical device-related pressure injuries under and around each medical device throughout their stay in the intensive care unit. The \"Case Report Form,\" \"MDRPIs Monitoring Form,\" \"Braden Q scale for children,\" National Pressure Injury Advisory Panel (NPIAP) Pressure Grading, and Glasgow Coma Scale were used in the research.</p><p><strong>Results: </strong>The incidence of medical device-related pressure injuries is 35.3 % (41/116). It was found that 38.1 % (16/42) of medical device-related pressure injuries developed due to Near-Infrared Spectroscopy (NIRS) probes, and 33.5 % (14/42) developed due to medical devices related to the respiratory system. In terms of anatomical location, 38.1 % occurred on the forehead, and 23.8 % on the arm/leg. The difference between birth weight, gestational age, development of MDRPIs in newborns receiving sedation and inotropes was found to be statistically significant. Regression analysis identified gestational age (p = 0.040, OR = 0.795, 95%CI = [0.632-1.000]) as an independent risk factor for the occurrence of medical device-related pressure injuries.</p><p><strong>Conclusions: </strong>The incidence of medical device-related pressure injuries in newborns was relatively high in this study, with gestational age being the most significant risk factor for MDRPIs formation. It is crucial for neonatal intensive care nurses to consider associated risk factors while providing newborn care and implement appropriate preventive measures to reduce the incidence of MDRPIs.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":" ","pages":""},"PeriodicalIF":4.6000,"publicationDate":"2024-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jtv.2024.09.005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: This study was conducted to investigate the incidence of medical device-related pressure injuries (MDRPIs) and the risk factors influencing their occurrence in the neonatal intensive care unit (NICU).

Method: This study is a prospective, descriptive study. The research was conducted with 116 newborns between June 1, 2022, and June 1, 2023. Newborns who stayed in the neonatal intensive care unit for at least 24 h were observed daily for medical device-related pressure injuries under and around each medical device throughout their stay in the intensive care unit. The "Case Report Form," "MDRPIs Monitoring Form," "Braden Q scale for children," National Pressure Injury Advisory Panel (NPIAP) Pressure Grading, and Glasgow Coma Scale were used in the research.

Results: The incidence of medical device-related pressure injuries is 35.3 % (41/116). It was found that 38.1 % (16/42) of medical device-related pressure injuries developed due to Near-Infrared Spectroscopy (NIRS) probes, and 33.5 % (14/42) developed due to medical devices related to the respiratory system. In terms of anatomical location, 38.1 % occurred on the forehead, and 23.8 % on the arm/leg. The difference between birth weight, gestational age, development of MDRPIs in newborns receiving sedation and inotropes was found to be statistically significant. Regression analysis identified gestational age (p = 0.040, OR = 0.795, 95%CI = [0.632-1.000]) as an independent risk factor for the occurrence of medical device-related pressure injuries.

Conclusions: The incidence of medical device-related pressure injuries in newborns was relatively high in this study, with gestational age being the most significant risk factor for MDRPIs formation. It is crucial for neonatal intensive care nurses to consider associated risk factors while providing newborn care and implement appropriate preventive measures to reduce the incidence of MDRPIs.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
新生儿病房中与医疗器械相关的压力损伤发生率及风险因素识别。
目的:本研究旨在调查新生儿重症监护室(NICU)中与医疗器械相关的压力损伤(MDRPIs)的发生率以及影响其发生的风险因素:本研究是一项前瞻性、描述性研究。研究对象为 2022 年 6 月 1 日至 2023 年 6 月 1 日期间的 116 名新生儿。在新生儿重症监护室停留至少 24 小时的新生儿在重症监护室停留期间,每天观察每个医疗设备下方和周围是否存在与医疗设备相关的压力损伤。研究中使用了 "病例报告表"、"MDRPIs监测表"、"儿童布莱登Q量表"、美国国家压力损伤咨询委员会(NPIAP)压力分级和格拉斯哥昏迷量表:与医疗器械相关的压力伤害发生率为 35.3%(41/116)。研究发现,38.1%(16/42)的医疗器械相关压力损伤是由近红外光谱探头造成的,33.5%(14/42)的医疗器械相关压力损伤是由呼吸系统造成的。就解剖位置而言,38.1%发生在前额,23.8%发生在手臂/腿部。研究发现,接受镇静剂和肌注的新生儿在出生体重、胎龄、MDRPIs发生率之间的差异具有统计学意义。回归分析发现,胎龄(p = 0.040,OR = 0.795,95%CI = [0.632-1.000])是发生医疗器械相关压力损伤的独立风险因素:结论:在本研究中,新生儿医疗器械相关压力损伤的发生率相对较高,其中胎龄是 MDRPIs 形成的最重要风险因素。新生儿重症监护护士在提供新生儿护理时必须考虑相关的风险因素,并采取适当的预防措施以降低 MDRPIs 的发生率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1