The relationship between intraocular pressure and glaucoma: An evolving concept

IF 18.6 1区 医学 Q1 OPHTHALMOLOGY Progress in Retinal and Eye Research Pub Date : 2024-09-19 DOI:10.1016/j.preteyeres.2024.101303
Sanjay G. Asrani , Elyse J. McGlumphy , Lama A. Al-Aswad , Craig J. Chaya , Shan Lin , David C. Musch , Ian Pitha , Alan L. Robin , Barbara Wirostko , Thomas V. Johnson
{"title":"The relationship between intraocular pressure and glaucoma: An evolving concept","authors":"Sanjay G. Asrani ,&nbsp;Elyse J. McGlumphy ,&nbsp;Lama A. Al-Aswad ,&nbsp;Craig J. Chaya ,&nbsp;Shan Lin ,&nbsp;David C. Musch ,&nbsp;Ian Pitha ,&nbsp;Alan L. Robin ,&nbsp;Barbara Wirostko ,&nbsp;Thomas V. Johnson","doi":"10.1016/j.preteyeres.2024.101303","DOIUrl":null,"url":null,"abstract":"<div><div>Intraocular pressure (IOP) is the most important modifiable risk factor for glaucoma and fluctuates considerably within patients over short and long time periods. Our field's understanding of IOP has evolved considerably in recent years, driven by tonometric technologies with increasing accuracy, reproducibility, and temporal resolution that have refined our knowledge regarding the relationship between IOP and glaucoma risk and pathogenesis. The goal of this article is to review the published literature pertinent to the following points: 1) the factors that determine IOP in physiologic and pathologic states; 2) technologies for measuring IOP; 3) scientific and clinical rationale for measuring diverse IOP metrics in patients with glaucoma; 4) the impact and shortcomings of current standard-of-care IOP monitoring approaches; 5) recommendations for approaches to IOP monitoring that could improve patient outcomes; and 6) research questions that must be answered to improve our understanding of how IOP contributes to disease progression. Retrospective and prospective data, including that from landmark clinical trials, document greater IOP fluctuations in glaucomatous than healthy eyes, tendencies for maximal daily IOP to occur outside of office hours, and, in addition to mean and maximal IOP, an association between IOP fluctuation and glaucoma progression that is independent of mean in-office IOP. Ambulatory IOP monitoring, measuring IOP outside of office hours and at different times of day and night, provides clinicians with discrete data that could improve patient outcomes. Eye care clinicians treating glaucoma based on isolated in-office IOP measurements may make treatment decisions without fully capturing the entire IOP profile of an individual. Data linking home blood pressure monitors and home glucose sensors to dramatically improved outcomes for patients with systemic hypertension and diabetes and will be reviewed as they pertain to the question of whether ambulatory tonometry is positioned to do the same for glaucoma management. Prospective randomized controlled studies are warranted to determine whether remote tonometry-based glaucoma management might reduce vision loss and improve patient outcomes.</div></div>","PeriodicalId":21159,"journal":{"name":"Progress in Retinal and Eye Research","volume":"103 ","pages":"Article 101303"},"PeriodicalIF":18.6000,"publicationDate":"2024-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Progress in Retinal and Eye Research","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1350946224000685","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Intraocular pressure (IOP) is the most important modifiable risk factor for glaucoma and fluctuates considerably within patients over short and long time periods. Our field's understanding of IOP has evolved considerably in recent years, driven by tonometric technologies with increasing accuracy, reproducibility, and temporal resolution that have refined our knowledge regarding the relationship between IOP and glaucoma risk and pathogenesis. The goal of this article is to review the published literature pertinent to the following points: 1) the factors that determine IOP in physiologic and pathologic states; 2) technologies for measuring IOP; 3) scientific and clinical rationale for measuring diverse IOP metrics in patients with glaucoma; 4) the impact and shortcomings of current standard-of-care IOP monitoring approaches; 5) recommendations for approaches to IOP monitoring that could improve patient outcomes; and 6) research questions that must be answered to improve our understanding of how IOP contributes to disease progression. Retrospective and prospective data, including that from landmark clinical trials, document greater IOP fluctuations in glaucomatous than healthy eyes, tendencies for maximal daily IOP to occur outside of office hours, and, in addition to mean and maximal IOP, an association between IOP fluctuation and glaucoma progression that is independent of mean in-office IOP. Ambulatory IOP monitoring, measuring IOP outside of office hours and at different times of day and night, provides clinicians with discrete data that could improve patient outcomes. Eye care clinicians treating glaucoma based on isolated in-office IOP measurements may make treatment decisions without fully capturing the entire IOP profile of an individual. Data linking home blood pressure monitors and home glucose sensors to dramatically improved outcomes for patients with systemic hypertension and diabetes and will be reviewed as they pertain to the question of whether ambulatory tonometry is positioned to do the same for glaucoma management. Prospective randomized controlled studies are warranted to determine whether remote tonometry-based glaucoma management might reduce vision loss and improve patient outcomes.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
眼压与青光眼的关系:一个不断演变的概念。
眼内压(IOP)是青光眼最重要的可改变风险因素,在患者体内的短期和长期波动都很大。近年来,眼压测量技术的准确性、可重复性和时间分辨率不断提高,完善了我们对眼压与青光眼风险和发病机制之间关系的认识。本文旨在回顾与以下几点相关的已发表文献:1) 生理和病理状态下决定眼压的因素;2) 测量眼压的技术;3) 测量青光眼患者各种眼压指标的科学和临床依据;4) 当前标准护理眼压监测方法的影响和不足;5) 可改善患者预后的眼压监测方法建议;6) 必须回答的研究问题,以提高我们对眼压如何导致疾病进展的认识。回顾性和前瞻性数据(包括来自具有里程碑意义的临床试验的数据)显示,青光眼患者的眼压波动比健康眼更大,每日最大眼压往往发生在非诊室时间,而且除了平均和最大眼压外,眼压波动与青光眼进展之间也存在关联,这种关联与诊室平均眼压无关。非卧床眼压监测可在非办公时间、白天和晚上的不同时段测量眼压,为临床医生提供离散数据,从而改善患者的治疗效果。眼科临床医生在治疗青光眼时,可能会根据诊室内的孤立眼压测量结果做出治疗决定,而无法全面了解患者的整个眼压状况。将家用血压计和家用血糖传感器与显著改善全身性高血压和糖尿病患者的治疗效果联系起来的数据,将与非卧床眼压测量是否能为青光眼治疗带来同样效果的问题联系起来进行审查。有必要进行前瞻性随机对照研究,以确定基于远程眼压测量的青光眼管理是否可以减少视力损失并改善患者的治疗效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
34.10
自引率
5.10%
发文量
78
期刊介绍: Progress in Retinal and Eye Research is a Reviews-only journal. By invitation, leading experts write on basic and clinical aspects of the eye in a style appealing to molecular biologists, neuroscientists and physiologists, as well as to vision researchers and ophthalmologists. The journal covers all aspects of eye research, including topics pertaining to the retina and pigment epithelial layer, cornea, tears, lacrimal glands, aqueous humour, iris, ciliary body, trabeculum, lens, vitreous humour and diseases such as dry-eye, inflammation, keratoconus, corneal dystrophy, glaucoma and cataract.
期刊最新文献
Cellular component transfer between photoreceptor cells of the retina. Role of epigenetics in corneal health and disease. Editorial Board Dual inheritance patterns: A spectrum of non-syndromic inherited retinal disease phenotypes with varying molecular mechanisms Eye on the horizon: The metabolic landscape of the RPE in aging and disease
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1