High temperature setup for measurement of Hall coefficient and electrical conductivity of thermoelectric materials.

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY Accounts of Chemical Research Pub Date : 2024-09-01 DOI:10.1063/5.0214582
B Agrawal, S Choudhary, P K Sahu, T Dasgupta
{"title":"High temperature setup for measurement of Hall coefficient and electrical conductivity of thermoelectric materials.","authors":"B Agrawal, S Choudhary, P K Sahu, T Dasgupta","doi":"10.1063/5.0214582","DOIUrl":null,"url":null,"abstract":"<p><p>An experimental setup has been developed for the simultaneous measurement of the Hall coefficient (RH) and electrical conductivity (σ) of thermoelectric (TE) specimens in the temperature range of 300-700 K. The van der Pauw geometry is utilized for the RH and σ measurements. The sample holder geometry has been designed for diverse TE specimen dimensions and easy sample mounting. A special feature of the holder geometry is that the same sample can be used for other relevant thermoelectric measurements such as the Seebeck coefficient and thermal diffusivity. This minimizes measurement errors associated with compositional or doping inhomogeneities. In the absence of high temperature standard reference materials for Hall coefficient measurements, silicon samples with different doping concentrations have been used to verify the accuracy of the instrument. Additionally, the electrical conductivity data have been validated by measurements on the same samples in a calibrated setup. Repeat measurements indicate a maximum standard deviation of ±3% and ±0.5% for the RH and σ data in the studied temperature range. Furthermore, comparisons with the calibrated setup indicate deviations within ±3% for the σ data. The suitability of the measurement setup for TE specimens has been demonstrated using measurements on n-type (Mg2Sn) and p-type (Mg3Sb2) specimens with carrier concentrations in the range of 1019-1020 cm-3.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1063/5.0214582","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

An experimental setup has been developed for the simultaneous measurement of the Hall coefficient (RH) and electrical conductivity (σ) of thermoelectric (TE) specimens in the temperature range of 300-700 K. The van der Pauw geometry is utilized for the RH and σ measurements. The sample holder geometry has been designed for diverse TE specimen dimensions and easy sample mounting. A special feature of the holder geometry is that the same sample can be used for other relevant thermoelectric measurements such as the Seebeck coefficient and thermal diffusivity. This minimizes measurement errors associated with compositional or doping inhomogeneities. In the absence of high temperature standard reference materials for Hall coefficient measurements, silicon samples with different doping concentrations have been used to verify the accuracy of the instrument. Additionally, the electrical conductivity data have been validated by measurements on the same samples in a calibrated setup. Repeat measurements indicate a maximum standard deviation of ±3% and ±0.5% for the RH and σ data in the studied temperature range. Furthermore, comparisons with the calibrated setup indicate deviations within ±3% for the σ data. The suitability of the measurement setup for TE specimens has been demonstrated using measurements on n-type (Mg2Sn) and p-type (Mg3Sb2) specimens with carrier concentrations in the range of 1019-1020 cm-3.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于测量热电材料霍尔系数和电导率的高温装置。
我们开发了一套实验装置,用于在 300-700 K 温度范围内同时测量热电(TE)试样的霍尔系数(RH)和电导率(σ)。样品支架的几何形状是针对不同的 TE 试样尺寸设计的,便于样品安装。样品架几何形状的一个特点是,同一样品可用于其他相关的热电测量,如塞贝克系数和热扩散率。这最大程度地减少了与成分或掺杂不均匀性相关的测量误差。由于缺乏用于霍尔系数测量的高温标准参考材料,我们使用了不同掺杂浓度的硅样品来验证仪器的准确性。此外,电导率数据还通过在校准装置中对相同样品的测量进行了验证。重复测量结果表明,在所研究的温度范围内,相对湿度和 σ 数据的最大标准偏差分别为 ±3% 和 ±0.5%。此外,与校准设置的比较表明,σ 数据的偏差在 ±3% 以内。通过对载流子浓度在 1019-1020 cm-3 范围内的 n 型(Mg2Sn)和 p 型(Mg3Sb2)试样进行测量,证明了该测量装置对 TE 试样的适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
期刊最新文献
Mentorship in academic musculoskeletal radiology: perspectives from a junior faculty member. Underlying synovial sarcoma undiagnosed for more than 20 years in a patient with regional pain: a case report. Sacrococcygeal chordoma with spontaneous regression due to a large hemorrhagic component. Associations of cumulative voriconazole dose, treatment duration, and alkaline phosphatase with voriconazole-induced periostitis. Can the presence of SLAP-5 lesions be predicted by using the critical shoulder angle in traumatic anterior shoulder instability?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1