Colour Vision Changes across Lifespan: Insights from FM100 and CAD Tests.

Q2 Medicine Vision (Switzerland) Pub Date : 2024-09-06 DOI:10.3390/vision8030053
Renārs Trukša, Sergejs Fomins, Zane Jansone-Langina, Laura Tenisa
{"title":"Colour Vision Changes across Lifespan: Insights from FM100 and CAD Tests.","authors":"Renārs Trukša, Sergejs Fomins, Zane Jansone-Langina, Laura Tenisa","doi":"10.3390/vision8030053","DOIUrl":null,"url":null,"abstract":"<p><p>(1) Background: in this research study, colour vision was evaluated in individuals aged 19 to 70 years with and without red-green colour vision disorders. (2) Methods: study participant colour vision was assessed with anomaloscope, HRR, FM100 hue, and CAD tests. (3) Results: No significant correlation was found between participant age and chromatic sensitivity of the red-green colour opponent channel. However, a decrease in blue-yellow colour opponent channel chromatic sensitivity was confirmed with the FM100 hue test and CAD test. Analysis of FM100 hue test error scores across age groups revealed a decline in chromatic sensitivity in the short-wave region of visible light with increasing age. Comparison of the colour-deficient individual results of the CAD and anomaloscope tests confirmed that CAD test sensitivity and specificity reaches 100%. However, some individuals with deutan-type deficits were misclassified as having protan-type deficits. This study confirmed the effectiveness of the FM100 test in identifying individuals with moderate to severe colour vision deficits, with sensitivity and specificity rates of 81.25% and 95.38%. (4) Conclusions: It was found that the FM100 hue test effectively identifies individuals with moderate and severe red-green colour vision deficiencies. On the other hand, individuals with mild colour vision deficiencies may go undetected with the FM100 hue test.</p>","PeriodicalId":36586,"journal":{"name":"Vision (Switzerland)","volume":"8 3","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11417771/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vision (Switzerland)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/vision8030053","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

(1) Background: in this research study, colour vision was evaluated in individuals aged 19 to 70 years with and without red-green colour vision disorders. (2) Methods: study participant colour vision was assessed with anomaloscope, HRR, FM100 hue, and CAD tests. (3) Results: No significant correlation was found between participant age and chromatic sensitivity of the red-green colour opponent channel. However, a decrease in blue-yellow colour opponent channel chromatic sensitivity was confirmed with the FM100 hue test and CAD test. Analysis of FM100 hue test error scores across age groups revealed a decline in chromatic sensitivity in the short-wave region of visible light with increasing age. Comparison of the colour-deficient individual results of the CAD and anomaloscope tests confirmed that CAD test sensitivity and specificity reaches 100%. However, some individuals with deutan-type deficits were misclassified as having protan-type deficits. This study confirmed the effectiveness of the FM100 test in identifying individuals with moderate to severe colour vision deficits, with sensitivity and specificity rates of 81.25% and 95.38%. (4) Conclusions: It was found that the FM100 hue test effectively identifies individuals with moderate and severe red-green colour vision deficiencies. On the other hand, individuals with mild colour vision deficiencies may go undetected with the FM100 hue test.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
人一生中色觉的变化:从 FM100 和 CAD 测试中获得的启示。
(1) 背景:在这项研究中,对 19 至 70 岁患有和未患有红绿色觉障碍的人的色觉进行了评估。(2) 方法:使用反常镜、HRR、FM100 色调和 CAD 测试评估研究对象的色觉。(3)结果:研究人员的年龄与红绿对色通道的色敏感度之间没有发现明显的相关性。然而,通过 FM100 色调测试和 CAD 测试,证实了蓝-黄对色通道色敏感度的下降。对不同年龄组的 FM100 色调测试误差分数进行分析后发现,随着年龄的增长,可见光短波区域的色敏感度也在下降。对比色弱个体的 CAD 测试和异常镜测试结果,证实 CAD 测试的灵敏度和特异性均达到 100%。然而,一些有去丹型色弱的个体被误判为有原丹型色弱。这项研究证实了 FM100 测试在识别中度至重度色觉障碍者方面的有效性,其灵敏度和特异度分别为 81.25% 和 95.38%。(4) 结论:研究发现,FM100 色调测试能有效识别中度和重度红绿色觉障碍者。另一方面,轻度色觉缺陷者可能无法通过 FM100 色调测试检测出来。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Vision (Switzerland)
Vision (Switzerland) Health Professions-Optometry
CiteScore
2.30
自引率
0.00%
发文量
62
审稿时长
11 weeks
期刊最新文献
Optical Bench Evaluation of a Novel, Hydrophobic, Acrylic, One-Piece, Polyfocal Intraocular Lens with a "Zig-Zag" L-Loop Haptic Design. Optimal Timing for Intraocular Pressure Measurement Following Phacoemulsification Cataract Surgery: A Systematic Review and a Meta-Analysis. Corneal Endothelial Microscopy: Does a Manual Recognition of the Endothelial Cells Help the Morphometric Analysis Compared to a Fully Automatic Approach? Combined Epiretinal Proliferation and Internal Limiting Membrane Inverted Flap for the Treatment of Large Macular Holes. Comparison of Four Methods for Measuring Heterophoria and Accommodative Convergence over Accommodation Ratio.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1