Objective Refraction Status before and after Cycloplegia: From Childhood to Young Adulthood.

Q2 Medicine Vision (Switzerland) Pub Date : 2024-08-30 DOI:10.3390/vision8030051
Karola Panke, Megija Jorova
{"title":"Objective Refraction Status before and after Cycloplegia: From Childhood to Young Adulthood.","authors":"Karola Panke, Megija Jorova","doi":"10.3390/vision8030051","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed to evaluate the clinical information revealed after cycloplegia and assess how age and non-cycloplegic refractive status influence the classification of types of refractive error, as well as the relationship between age and cycloplegia-induced changes in the power of refractive errors. We analysed the records of 472 non-population-based ophthalmology practice patients aged 3-28 years (mean ± SD: 9.1 ± 4.6). Cycloplegia was induced with one drop of cyclopentolate 1% in each eye, and eye refraction was measured 30 ± 5 min later using an objective autorefractometer. Cycloplegia induced a clinically significant (≥0.50 D) hyperopic shift in the spherical equivalent of 60.2% of participants and a myopic shift in 1%, resulting in a 34.1% increase in the frequency of participants with hyperopia, while the frequency of those with myopia and emmetropia decreased by 5.5% and 23.3%, respectively. The average spherical equivalent difference (mean ± SD) induced by cycloplegia was 0.72 ± 0.73 D, with the highest difference observed in the 3-5 years age group (1.18 ± 0.85 D). The differences in astigmatism power (<i>p</i> = 0.84) and astigmatism axis (<i>p</i> = 0.97) between non-cycloplegic and cycloplegic conditions were not statistically significant.</p>","PeriodicalId":36586,"journal":{"name":"Vision (Switzerland)","volume":"8 3","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11417856/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vision (Switzerland)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/vision8030051","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

This study aimed to evaluate the clinical information revealed after cycloplegia and assess how age and non-cycloplegic refractive status influence the classification of types of refractive error, as well as the relationship between age and cycloplegia-induced changes in the power of refractive errors. We analysed the records of 472 non-population-based ophthalmology practice patients aged 3-28 years (mean ± SD: 9.1 ± 4.6). Cycloplegia was induced with one drop of cyclopentolate 1% in each eye, and eye refraction was measured 30 ± 5 min later using an objective autorefractometer. Cycloplegia induced a clinically significant (≥0.50 D) hyperopic shift in the spherical equivalent of 60.2% of participants and a myopic shift in 1%, resulting in a 34.1% increase in the frequency of participants with hyperopia, while the frequency of those with myopia and emmetropia decreased by 5.5% and 23.3%, respectively. The average spherical equivalent difference (mean ± SD) induced by cycloplegia was 0.72 ± 0.73 D, with the highest difference observed in the 3-5 years age group (1.18 ± 0.85 D). The differences in astigmatism power (p = 0.84) and astigmatism axis (p = 0.97) between non-cycloplegic and cycloplegic conditions were not statistically significant.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
屈光手术前后的客观屈光状态:从童年到成年。
本研究旨在评估环形角膜屈光手术后显示的临床信息,并评估年龄和非环形角膜屈光手术屈光状态如何影响屈光不正类型的分类,以及年龄与环形角膜屈光手术引起的屈光不正功率变化之间的关系。我们分析了 472 名年龄在 3-28 岁(平均 ± SD:9.1 ± 4.6)的非人群眼科患者的记录。在每只眼睛中滴入一滴 1%的环戊丙酸,诱发眼球震颤,30 ± 5 分钟后使用客观自动屈光仪测量眼睛屈光度。60.2%的参试者在接受环戊四醇眼药水治疗后,球镜等值发生了临床意义上显著的远视偏移(≥0.50 D),1%的参试者发生了近视偏移,导致参试者远视发生率增加了34.1%,而近视和散光发生率分别减少了5.5%和23.3%。球面屈光手术引起的平均球面等效差(平均值±标度)为 0.72 ± 0.73 D,3-5 岁年龄组的球面等效差最大(1.18 ± 0.85 D)。散光功率(p = 0.84)和散光轴(p = 0.97)在非屈光不正和屈光不正条件下的差异无统计学意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Vision (Switzerland)
Vision (Switzerland) Health Professions-Optometry
CiteScore
2.30
自引率
0.00%
发文量
62
审稿时长
11 weeks
期刊最新文献
Optical Bench Evaluation of a Novel, Hydrophobic, Acrylic, One-Piece, Polyfocal Intraocular Lens with a "Zig-Zag" L-Loop Haptic Design. Optimal Timing for Intraocular Pressure Measurement Following Phacoemulsification Cataract Surgery: A Systematic Review and a Meta-Analysis. Corneal Endothelial Microscopy: Does a Manual Recognition of the Endothelial Cells Help the Morphometric Analysis Compared to a Fully Automatic Approach? Combined Epiretinal Proliferation and Internal Limiting Membrane Inverted Flap for the Treatment of Large Macular Holes. Comparison of Four Methods for Measuring Heterophoria and Accommodative Convergence over Accommodation Ratio.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1