Lung ultrasound score for prediction of bronchopulmonary dysplasia in newborns: A meta-analysis.

IF 1.4 4区 医学 Q4 ENGINEERING, BIOMEDICAL Technology and Health Care Pub Date : 2024-09-11 DOI:10.3233/THC-240832
Xian Zhang, Xia Yang, Yanhong Li
{"title":"Lung ultrasound score for prediction of bronchopulmonary dysplasia in newborns: A meta-analysis.","authors":"Xian Zhang, Xia Yang, Yanhong Li","doi":"10.3233/THC-240832","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Bronchopulmonary dysplasia (BPD) ranks among preterm infants' most common and severe respiratory diseases. Lung ultrasound scores (LUS) play a vital role in predicting early BPD and guiding treatment and intervention strategies for affected patients.</p><p><strong>Objective: </strong>Performed a meta-analysis to assess the diagnostic LUS for newborns with BPD.</p><p><strong>Methods: </strong>Online electronic databases such as MEDLINE, CINAHL, the Cochrane Library, and Web of Science were used to retrieve relevant research until May 2023. A total of 117 literatures were collected, and ten eligible articles were selected for meta-analysis.</p><p><strong>Results: </strong>Meta-analysis was performed on 10 studies (1274 neonates). LUS at 7 days after birth (7 days of life, DOL 7) showed good diagnostic accuracy for any type of BPD, moderate and severe BPD. DOL 7 was more accurate in predicting all types of BPD (AUC = 0.87, sensitivity = 0.75, specificity = 0.83) than moderate and severe BPD (AUC = 0.80, sensitivity = 0.69, specificity = 0.79). There was no statistical significance between DOL 7 and DOL 14 in their accuracy for predicting all types of BPD (difference in AUC = 0.04, p= 0.068). There was no notable distinction between DOL 7 and DOL 14 in their accuracy for predicting moderate and severe BPD (difference in AUC =-0.04, p= 0.104).</p><p><strong>Conclusions: </strong>The diagnostic efficacy of LUS on DOL 7 in predicting the occurrence of all types of BDP and moderate-severe BPD is determined. This will facilitate rapid and accurate detection and timely treatment, thereby reducing the risk of neonatal mortality and sequelae.</p>","PeriodicalId":48978,"journal":{"name":"Technology and Health Care","volume":" ","pages":""},"PeriodicalIF":1.4000,"publicationDate":"2024-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Technology and Health Care","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3233/THC-240832","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Bronchopulmonary dysplasia (BPD) ranks among preterm infants' most common and severe respiratory diseases. Lung ultrasound scores (LUS) play a vital role in predicting early BPD and guiding treatment and intervention strategies for affected patients.

Objective: Performed a meta-analysis to assess the diagnostic LUS for newborns with BPD.

Methods: Online electronic databases such as MEDLINE, CINAHL, the Cochrane Library, and Web of Science were used to retrieve relevant research until May 2023. A total of 117 literatures were collected, and ten eligible articles were selected for meta-analysis.

Results: Meta-analysis was performed on 10 studies (1274 neonates). LUS at 7 days after birth (7 days of life, DOL 7) showed good diagnostic accuracy for any type of BPD, moderate and severe BPD. DOL 7 was more accurate in predicting all types of BPD (AUC = 0.87, sensitivity = 0.75, specificity = 0.83) than moderate and severe BPD (AUC = 0.80, sensitivity = 0.69, specificity = 0.79). There was no statistical significance between DOL 7 and DOL 14 in their accuracy for predicting all types of BPD (difference in AUC = 0.04, p= 0.068). There was no notable distinction between DOL 7 and DOL 14 in their accuracy for predicting moderate and severe BPD (difference in AUC =-0.04, p= 0.104).

Conclusions: The diagnostic efficacy of LUS on DOL 7 in predicting the occurrence of all types of BDP and moderate-severe BPD is determined. This will facilitate rapid and accurate detection and timely treatment, thereby reducing the risk of neonatal mortality and sequelae.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
预测新生儿支气管肺发育不良的肺部超声评分:荟萃分析
背景:支气管肺发育不良(BPD)是早产儿最常见、最严重的呼吸系统疾病之一。肺部超声评分(LUS)在预测早期 BPD 并指导受影响患者的治疗和干预策略方面发挥着重要作用:进行一项荟萃分析,评估诊断 BPD 新生儿的 LUS:方法:使用 MEDLINE、CINAHL、Cochrane Library 和 Web of Science 等在线电子数据库检索截至 2023 年 5 月的相关研究。共收集到 117 篇文献,筛选出 10 篇符合条件的文章进行荟萃分析:对10项研究(1274名新生儿)进行了荟萃分析。出生后 7 天(出生后 7 天,DOL 7)的 LUS 对任何类型的 BPD、中度和重度 BPD 都显示出良好的诊断准确性。与中度和重度 BPD(AUC = 0.80,灵敏度 = 0.69,特异性 = 0.79)相比,DOL 7 预测所有类型 BPD 的准确性更高(AUC = 0.87,灵敏度 = 0.75,特异性 = 0.83)。DOL 7 和 DOL 14 在预测所有类型的 BPD 的准确性方面没有统计学意义(AUC = 0.04,p= 0.068)。在预测中度和重度 BPD 的准确性方面,DOL 7 和 DOL 14 没有明显区别(AUC 差异 =-0.04,p= 0.104):结论:DOL 7 的 LUS 对预测各种类型的 BDP 和中度-重度 BPD 的诊断效果是确定的。结论:确定了 LUS 对 DOL 7 预测所有类型 BDP 和中重度 BPD 的诊断效果,这将有助于快速、准确地检测和及时治疗,从而降低新生儿死亡和后遗症的风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Technology and Health Care
Technology and Health Care HEALTH CARE SCIENCES & SERVICES-ENGINEERING, BIOMEDICAL
CiteScore
2.10
自引率
6.20%
发文量
282
审稿时长
>12 weeks
期刊介绍: Technology and Health Care is intended to serve as a forum for the presentation of original articles and technical notes, observing rigorous scientific standards. Furthermore, upon invitation, reviews, tutorials, discussion papers and minisymposia are featured. The main focus of THC is related to the overlapping areas of engineering and medicine. The following types of contributions are considered: 1.Original articles: New concepts, procedures and devices associated with the use of technology in medical research and clinical practice are presented to a readership with a widespread background in engineering and/or medicine. In particular, the clinical benefit deriving from the application of engineering methods and devices in clinical medicine should be demonstrated. Typically, full length original contributions have a length of 4000 words, thereby taking duly into account figures and tables. 2.Technical Notes and Short Communications: Technical Notes relate to novel technical developments with relevance for clinical medicine. In Short Communications, clinical applications are shortly described. 3.Both Technical Notes and Short Communications typically have a length of 1500 words. Reviews and Tutorials (upon invitation only): Tutorial and educational articles for persons with a primarily medical background on principles of engineering with particular significance for biomedical applications and vice versa are presented. The Editorial Board is responsible for the selection of topics. 4.Minisymposia (upon invitation only): Under the leadership of a Special Editor, controversial or important issues relating to health care are highlighted and discussed by various authors. 5.Letters to the Editors: Discussions or short statements (not indexed).
期刊最新文献
Three-dimensional printed apical barrier model technology for pre-clinical dental education. Arterial variations and hemodynamic impact in the upper limb: Insights from an observational study. Validation of endoplasmic reticulum stress-related gene signature to predict prognosis and immune landscape of patients with non-small cell lung cancer. Lung ultrasound score for prediction of bronchopulmonary dysplasia in newborns: A meta-analysis. Predicting survival in sepsis: The prognostic value of NLR and BAR ratios.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1