{"title":"Design and Implementation of Integrated Dual-Mode Pulse and Continuous-Wave Electron Paramagnetic Resonance Spectrometers.","authors":"Jui-Hung Sun, Difei Wu, Peter Qin, Constantine Sideris","doi":"10.1109/TBCAS.2024.3465210","DOIUrl":null,"url":null,"abstract":"<p><p>Electron paramagnetic resonance (EPR) is a powerful spectroscopic technique that allows direct detection and characterization of radicals containing unpaired electron(s). The development of portable, low-power EPR sensing modalities has the potential to significantly expand the utility of EPR in a broad range of fields, ranging from basic science to practical applications such as point-of-care diagnostics. The two major methodologies of EPR are continuous-wave (CW) EPR, where the frequency or field is swept with a constant excitation, and pulse EPR, where short pulses induce a transient signal. In this work, we present the first realization of a fully integrated pulse EPR spectrometer on-chip. The spectrometer utilizes a subharmonic direct-conversion architecture that enables an on-chip oscillator to be used as a dual-mode EPR sensing cell, capable of both CW and pulse-mode operation. An on-chip reference oscillator is used to injection-lock the sensor to form pulses and also to downconvert the pulse EPR signal. A proof-of-concept spectrometer IC with two independent sensing cells is presented, which achieves a pulse sensitivity of 4.6 x 10<sup>9</sup> spins (1000 averages) and a CW sensitivity of 2.9 x 10<sup>9</sup> spins/ √{Hz} and can be powered and controlled via a computer USB interface. The sensing cells consume as little as 2.1mW (CW mode), and the system is tunable over a wide frequency range of 12.8-14.9GHz (CW/pulse). Single-pulse free induction decay (FID), two-pulse inversion recovery, two-pulse Hahn echo, three-pulse stimulated echo, and CW experiments demonstrate the viability of the spectrometer for use in portable EPR sensing.</p>","PeriodicalId":94031,"journal":{"name":"IEEE transactions on biomedical circuits and systems","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on biomedical circuits and systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TBCAS.2024.3465210","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Electron paramagnetic resonance (EPR) is a powerful spectroscopic technique that allows direct detection and characterization of radicals containing unpaired electron(s). The development of portable, low-power EPR sensing modalities has the potential to significantly expand the utility of EPR in a broad range of fields, ranging from basic science to practical applications such as point-of-care diagnostics. The two major methodologies of EPR are continuous-wave (CW) EPR, where the frequency or field is swept with a constant excitation, and pulse EPR, where short pulses induce a transient signal. In this work, we present the first realization of a fully integrated pulse EPR spectrometer on-chip. The spectrometer utilizes a subharmonic direct-conversion architecture that enables an on-chip oscillator to be used as a dual-mode EPR sensing cell, capable of both CW and pulse-mode operation. An on-chip reference oscillator is used to injection-lock the sensor to form pulses and also to downconvert the pulse EPR signal. A proof-of-concept spectrometer IC with two independent sensing cells is presented, which achieves a pulse sensitivity of 4.6 x 109 spins (1000 averages) and a CW sensitivity of 2.9 x 109 spins/ √{Hz} and can be powered and controlled via a computer USB interface. The sensing cells consume as little as 2.1mW (CW mode), and the system is tunable over a wide frequency range of 12.8-14.9GHz (CW/pulse). Single-pulse free induction decay (FID), two-pulse inversion recovery, two-pulse Hahn echo, three-pulse stimulated echo, and CW experiments demonstrate the viability of the spectrometer for use in portable EPR sensing.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
集成双模脉冲和连续波电子顺磁共振频谱仪的设计与实现。
电子顺磁共振(EPR)是一种功能强大的光谱学技术,可以直接检测和表征含有未配对电子的自由基。便携式、低功耗 EPR 传感模式的开发有可能极大地扩展 EPR 在从基础科学到实际应用(如护理点诊断)等广泛领域的用途。EPR 的两种主要方法是连续波 (CW) EPR 和脉冲 EPR,前者是以恒定激励扫频或扫场,后者是以短脉冲诱发瞬态信号。在这项工作中,我们首次在芯片上实现了完全集成的脉冲 EPR 光谱仪。该光谱仪采用亚谐波直接转换架构,可将片上振荡器用作双模 EPR 传感单元,既能进行连续波操作,也能进行脉冲模式操作。片上基准振荡器用于注入锁定传感器以形成脉冲,同时也用于下变频脉冲 EPR 信号。演示的概念验证光谱仪集成电路有两个独立的传感单元,脉冲灵敏度达到 4.6 x 109 个自旋(1000 平均值),CW 灵敏度为 2.9 x 109 个自旋/√{Hz},可通过计算机 USB 接口供电和控制。传感单元的功耗低至 2.1mW(CW 模式),系统可在 12.8-14.9GHz 的宽频率范围内进行调谐(CW/脉冲)。单脉冲自由感应衰减 (FID)、双脉冲反转恢复、双脉冲哈恩回波、三脉冲刺激回波和 CW 实验证明了该光谱仪在便携式 EPR 传感中的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Dynamic sub-array selection-based energy-efficient localization and tracking method to power implanted medical devices in scattering heterogenous media employing ultrasound. A Reconfigurable Bidirectional Wireless Power and Full-Duplex Data Transceiver IC for Wearable Biomedical Applications. An Ultrasonic Transceiver for Non-Invasive Intracranial Pressure Sensing. BrainForest: Neuromorphic Multiplier-Less Bit-Serial Weight-Memory-Optimized 1024-Tree Brain-State Classification Processor. Fully Integrated Pneumatic-Free and Magnet-Free CMOS Ferrofluidic Platform for Comprehensive Biomolecular Processing.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1