Time resolved x-ray diffraction using the flexible imaging diffraction diagnostic for laser experiments (FIDDLE) at the National Ignition Facility (NIF): Preliminary assessment of diffraction precision.
C E Vennari, N E Palmer, P R Nyholm, N S Bhandakar, S R Nagel, R B Petre, C V Stan, J H Eggert, D K Bradley, Y Ping, A Thomas, D C Swift, A C Carpenter, A J MacKinnon, L R Benedetti
{"title":"Time resolved x-ray diffraction using the flexible imaging diffraction diagnostic for laser experiments (FIDDLE) at the National Ignition Facility (NIF): Preliminary assessment of diffraction precision.","authors":"C E Vennari, N E Palmer, P R Nyholm, N S Bhandakar, S R Nagel, R B Petre, C V Stan, J H Eggert, D K Bradley, Y Ping, A Thomas, D C Swift, A C Carpenter, A J MacKinnon, L R Benedetti","doi":"10.1063/5.0219491","DOIUrl":null,"url":null,"abstract":"<p><p>The Flexible Imaging Diffraction Diagnostic for Laser Experiments (FIDDLE) is a new diagnostic at the National Ignition Facility (NIF) designed to observe in situ solid-solid phase changes at high pressures using time resolved x-ray diffraction. FIDDLE currently incorporates five Icarus ultrafast x-ray imager sensors that take 2 ns snapshots and can be tuned to collect X-rays for tens of ns. The platform utilizes the laser power at NIF for both the laser drive and the generation of 10 keV X-rays for ∼10 ns using a Ge backlighter foil. We aim to use FIDDLE to observe diffraction at different times during compression to probe the kinetics of phase changes. Pb undergoes two solid-solid phase transitions during ramp compression: from face centered cubic (FCC) to hexagonal close packed (HCP) and HCP to body centered cubic (BCC). Results will be reported on some of the first shots using the FIDDLE diagnostic at NIF on ramp compressed Pb to a peak pressure of ∼110 GPa and a single undriven CeO2 calibration shot. A discussion of the uncertainties in the observed diffraction is included.</p>","PeriodicalId":21111,"journal":{"name":"Review of Scientific Instruments","volume":"95 9","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Review of Scientific Instruments","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1063/5.0219491","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0
Abstract
The Flexible Imaging Diffraction Diagnostic for Laser Experiments (FIDDLE) is a new diagnostic at the National Ignition Facility (NIF) designed to observe in situ solid-solid phase changes at high pressures using time resolved x-ray diffraction. FIDDLE currently incorporates five Icarus ultrafast x-ray imager sensors that take 2 ns snapshots and can be tuned to collect X-rays for tens of ns. The platform utilizes the laser power at NIF for both the laser drive and the generation of 10 keV X-rays for ∼10 ns using a Ge backlighter foil. We aim to use FIDDLE to observe diffraction at different times during compression to probe the kinetics of phase changes. Pb undergoes two solid-solid phase transitions during ramp compression: from face centered cubic (FCC) to hexagonal close packed (HCP) and HCP to body centered cubic (BCC). Results will be reported on some of the first shots using the FIDDLE diagnostic at NIF on ramp compressed Pb to a peak pressure of ∼110 GPa and a single undriven CeO2 calibration shot. A discussion of the uncertainties in the observed diffraction is included.
期刊介绍:
Review of Scientific Instruments, is committed to the publication of advances in scientific instruments, apparatuses, and techniques. RSI seeks to meet the needs of engineers and scientists in physics, chemistry, and the life sciences.