Ross Hamilton, Olivia M. McCarthy, Stephen C. Bain, Richard M. Bracken
{"title":"Continuous measurement of interstitial glycaemia in professional female UCI world tour cyclists undertaking a 9-day cycle training camp","authors":"Ross Hamilton, Olivia M. McCarthy, Stephen C. Bain, Richard M. Bracken","doi":"10.1002/ejsc.12201","DOIUrl":null,"url":null,"abstract":"<p>Nine cyclists (age: 26 ± 5 years, height: 168 ± 5 cm and mass 58.5 ± 4.5 kg) were observed using continuous glucose monitoring devices throughout a training camp. Interstitial glucose [iG] data were captured via the Abbott libre sense biosensor (Abbott Laboratories) and paired with the Supersapiens software (TT1 Products Inc.). [iG] data were split into time ranges, that is, overall (24-hourly), day-time (06:00–23:59), night-time (00:00–05:59) and exercise. [iG] data were stratified into percentage of time, below range ([TBR] < 70 mg/dl), in range ([TIR] 70–140 mg/dl) and above range ([TAR] ≥ 141 mg/dl). Differences in diurnal and nocturnal data were analysed via repeated measures analysis of variance and paired <i>t</i>-tests where appropriate. <i>p</i>-value of ≤0.05 was accepted as significant. Riders spent an average of 3 ± 1% TAR, 93 ± 2% TIR and 8 ± 3% TBR. Mean 24 h [iG] was 93 ± 2 mg/dl with a coefficient of variation (CV) of 18 ± 1%. Mean (day: 95 ± 3 vs. night: 86 ± 3 mg/dl and <i>p</i> < 0.001) and CV (day: 18 ± 1 vs. night: 9 ± 1% and <i>p</i> < 0.001) in [iG] were higher during the day-time hours. TAR was greater during the day (day: 3 ± 1 vs. night: 0 ± 0% and <i>p</i> < 0.001) but TBR and TIR were similar. Glucose levels below the clinical range may have implications for those without diabetes and warrants further investigation.</p>","PeriodicalId":93999,"journal":{"name":"European journal of sport science","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/ejsc.12201","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European journal of sport science","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/ejsc.12201","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Nine cyclists (age: 26 ± 5 years, height: 168 ± 5 cm and mass 58.5 ± 4.5 kg) were observed using continuous glucose monitoring devices throughout a training camp. Interstitial glucose [iG] data were captured via the Abbott libre sense biosensor (Abbott Laboratories) and paired with the Supersapiens software (TT1 Products Inc.). [iG] data were split into time ranges, that is, overall (24-hourly), day-time (06:00–23:59), night-time (00:00–05:59) and exercise. [iG] data were stratified into percentage of time, below range ([TBR] < 70 mg/dl), in range ([TIR] 70–140 mg/dl) and above range ([TAR] ≥ 141 mg/dl). Differences in diurnal and nocturnal data were analysed via repeated measures analysis of variance and paired t-tests where appropriate. p-value of ≤0.05 was accepted as significant. Riders spent an average of 3 ± 1% TAR, 93 ± 2% TIR and 8 ± 3% TBR. Mean 24 h [iG] was 93 ± 2 mg/dl with a coefficient of variation (CV) of 18 ± 1%. Mean (day: 95 ± 3 vs. night: 86 ± 3 mg/dl and p < 0.001) and CV (day: 18 ± 1 vs. night: 9 ± 1% and p < 0.001) in [iG] were higher during the day-time hours. TAR was greater during the day (day: 3 ± 1 vs. night: 0 ± 0% and p < 0.001) but TBR and TIR were similar. Glucose levels below the clinical range may have implications for those without diabetes and warrants further investigation.