Assessment of Anatomical Variations in the Anterior Loop of the Mental Nerve in the Northeast Population to Estimate a Safe Zone for Implant Prosthesis: An Institution-Based Study.
{"title":"Assessment of Anatomical Variations in the Anterior Loop of the Mental Nerve in the Northeast Population to Estimate a Safe Zone for Implant Prosthesis: An Institution-Based Study.","authors":"Hamari Debbarma, Jogeswar Barman, Sonu Agarwala, Barasha Goswami, Alak Bhattacharyya, Joshni Loitongbam","doi":"10.4103/jpbs.jpbs_293_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The precise location of the anterior loop is of utmost importance during implant surgery to avoid any postoperative complications. The aim of the institution-based study was to determine the prevalence of the anterior loop with respect to age and gender in the northeast population.</p><p><strong>Materials and methods: </strong>Sixty outpatients opting for implant prostheses in the interforaminal region of the mandible were enrolled in this study based on the inclusion and exclusion criteria.</p><p><strong>Results: </strong>The anterior loop was identified in 18.3% of the total subjects, and the mean length of the anterior loop was found to be 3.37 ± 0.53 mm. Planning for prosthetic-driven the implant placement was possible in 54.5% of the subjects.</p><p><strong>Conclusions: </strong>Proper treatment planning using cone beam computed tomography (CBCT) with a radiographic stent is paramount important for the safe placement of implant in the presence of the anterior loop of the mental nerve.</p>","PeriodicalId":94339,"journal":{"name":"Journal of pharmacy & bioallied sciences","volume":"16 Suppl 3","pages":"S2419-S2421"},"PeriodicalIF":0.7000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11426859/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of pharmacy & bioallied sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jpbs.jpbs_293_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/31 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The precise location of the anterior loop is of utmost importance during implant surgery to avoid any postoperative complications. The aim of the institution-based study was to determine the prevalence of the anterior loop with respect to age and gender in the northeast population.
Materials and methods: Sixty outpatients opting for implant prostheses in the interforaminal region of the mandible were enrolled in this study based on the inclusion and exclusion criteria.
Results: The anterior loop was identified in 18.3% of the total subjects, and the mean length of the anterior loop was found to be 3.37 ± 0.53 mm. Planning for prosthetic-driven the implant placement was possible in 54.5% of the subjects.
Conclusions: Proper treatment planning using cone beam computed tomography (CBCT) with a radiographic stent is paramount important for the safe placement of implant in the presence of the anterior loop of the mental nerve.