{"title":"[Analysis of the results of personal monitoring to ionizing radiation at workplaces].","authors":"Sylwia Papierz, Joanna Domienik-Andrzejewska","doi":"10.13075/mp.5893.01557","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The paper presents the results of dosimetric measurements routinely performed by the Radiation Protection Department of the Nofer Institute of Occupational Medicine (NIOM) in Łódź in 2022 for people occupationally exposed to X and γ radiation.</p><p><strong>Material and methods: </strong>The evaluation of the effective dose as part of individual dosimetry was provided using the film or thermoluminescent dosimetry (TLD). Additionally, based exclusively on the TLD method, measurements of the ambient dose equivalent H*(10) and personal dose equivalents Hp(0.07) and Hp(3) were performed. In 2022, the dosimetric service of the Radiological Protection Department of the NIOM covered >30 000 workers employed in >4500 laboratories (mainly health care departments). All measurements were performed in accordance with accredited research procedures (number AB 327).</p><p><strong>Results: </strong>In 2022, the average annual dose of Hp(10) was equal to 0.26 mSv, whereas Hp(0.07) measured using ring and wrist dosimetry was equal to 0.63 mSv and 0.78 mSv, respectively. In turn, the average Hp(3) value was 0.21 mSv. In 2022, there was not a single case of exceeding the annual dose limit among people measured by the NIOM.</p><p><strong>Conclusions: </strong>The data collected in the \"Dosimetry\" database of the NIOM and a detailed analysis of annual doses received by people occupationally exposed to ionizing radiation indicate a well-functioning radiological protection system in Poland. Med Pr Work Health Saf. 2024;75(5):415-423.</p>","PeriodicalId":101460,"journal":{"name":"Medycyna pracy","volume":" ","pages":"415-423"},"PeriodicalIF":0.0000,"publicationDate":"2024-11-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medycyna pracy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.13075/mp.5893.01557","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/1 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The paper presents the results of dosimetric measurements routinely performed by the Radiation Protection Department of the Nofer Institute of Occupational Medicine (NIOM) in Łódź in 2022 for people occupationally exposed to X and γ radiation.

Material and methods: The evaluation of the effective dose as part of individual dosimetry was provided using the film or thermoluminescent dosimetry (TLD). Additionally, based exclusively on the TLD method, measurements of the ambient dose equivalent H*(10) and personal dose equivalents Hp(0.07) and Hp(3) were performed. In 2022, the dosimetric service of the Radiological Protection Department of the NIOM covered >30 000 workers employed in >4500 laboratories (mainly health care departments). All measurements were performed in accordance with accredited research procedures (number AB 327).

Results: In 2022, the average annual dose of Hp(10) was equal to 0.26 mSv, whereas Hp(0.07) measured using ring and wrist dosimetry was equal to 0.63 mSv and 0.78 mSv, respectively. In turn, the average Hp(3) value was 0.21 mSv. In 2022, there was not a single case of exceeding the annual dose limit among people measured by the NIOM.

Conclusions: The data collected in the "Dosimetry" database of the NIOM and a detailed analysis of annual doses received by people occupationally exposed to ionizing radiation indicate a well-functioning radiological protection system in Poland. Med Pr Work Health Saf. 2024;75(5):415-423.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[工作场所电离辐射个人监测结果分析]。
背景介绍本文介绍了罗兹诺夫职业医学研究所(NIOM)辐射防护部 2022 年对职业暴露于 X 和 γ 辐射的人员进行的常规剂量测定结果:作为个人剂量测定的一部分,使用胶片或热释光剂量测定法(TLD)对有效剂量进行评估。此外,还专门使用热释光法测量了环境剂量当量 H*(10)以及个人剂量当量 Hp(0.07) 和 Hp(3)。2022 年,NIOM 辐射防护部的剂量测定服务覆盖了超过 4500 个实验室(主要是医疗保健部门)的超过 30000 名工作人员。所有测量均按照认可的研究程序(编号AB 327)进行:2022 年,Hp(10) 的年平均剂量等于 0.26 毫西弗,而使用环形和腕部剂量计测量的 Hp(0.07) 分别等于 0.63 毫西弗和 0.78 毫西弗。而 Hp(3) 的平均值为 0.21 mSv。2022 年,NIOM 测量的人群中没有一例超过年度剂量限值:结论:NIOM "剂量测定 "数据库中收集的数据以及对电离辐射职业人群年剂量的详细分析表明,波兰的辐射防护系统运行良好。Med Pr Work Health Saf.2024;75(5).
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Occupational anaphylaxis to food. [The changing epidemiology of tick-borne encephalitis: epidemic surveillance and disease prevention challenges]. [Exposure to bioaerosol in the residential environment]. [Assessment of the importance of teleradiology services in the opinion of electroradiologists in Poland]. [Breast cancer under control - risk calculators].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1