Diagnosis of periprosthetic loosening of total hip and knee arthroplasty using 68Gallium-Zoledronate PET/CT.

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2024-10-01 DOI:10.1007/s00402-024-05562-5
A Touet, S Koob, S Kürpig, J Roos, F Roesch, D C Wirtz, M Essler, F C Gaertner
{"title":"Diagnosis of periprosthetic loosening of total hip and knee arthroplasty using <sup>68</sup>Gallium-Zoledronate PET/CT.","authors":"A Touet, S Koob, S Kürpig, J Roos, F Roesch, D C Wirtz, M Essler, F C Gaertner","doi":"10.1007/s00402-024-05562-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Periprosthetic loosening is a major complication after total hip and knee arthroplasty. Early and accurate diagnosis is essential to choose the right therapeutic path and to avoid further complications. The aim of the study was to evaluate the diagnostic performance of <sup>68</sup>Gallium-Zoledronate ([<sup>68</sup>Ga]Ga-DOTA<sup>Zol</sup>) PET/CT in detecting periprosthetic loosening in total hip (THA) and total knee arthroplasty (TKA).</p><p><strong>Methods: </strong>This retrospective study included 26 patients with painful prosthesis (THA n = 17; TKA n = 16) and clinical suspicion of periprosthetic loosening, but without a confirmed diagnosis. Patients underwent [<sup>68</sup>Ga]Ga-DOTA<sup>Zol</sup> PET/CT at least one year post-implantation. Diagnosis was confirmed through revision surgery or long-term clinical follow-up, with an observation period of at least 6 months. The analysis included both an assessment of the prosthesis as a unit and a separate evaluation of the individual components. Statistical analysis involved calculating sensitivity, specificity and accuracy using SPSS.</p><p><strong>Results: </strong>Overall, a sensitivity of 77.8%, a specificity of 95.8% and an accuracy of 90.9% were found for detecting periprosthetic loosening, when considering the prosthesis as a unit. Individual component analyses showed a sensitivity of 71.4% and specificity of 96.2%.</p><p><strong>Conclusion: </strong>The use of [<sup>68</sup>Ga]Ga-DOTA<sup>Zol</sup> PET/CT in periprosthetic loosening is a remarkable diagnostic tool and a promising approach. In comparison to established radionuclide tracers, <sup>68</sup>Gallium-Zoledronate offers notable advantages due to its availability via <sup>68</sup>Ge/<sup>68</sup>Ga-generators, improving its potential for clinical application.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00402-024-05562-5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Periprosthetic loosening is a major complication after total hip and knee arthroplasty. Early and accurate diagnosis is essential to choose the right therapeutic path and to avoid further complications. The aim of the study was to evaluate the diagnostic performance of 68Gallium-Zoledronate ([68Ga]Ga-DOTAZol) PET/CT in detecting periprosthetic loosening in total hip (THA) and total knee arthroplasty (TKA).

Methods: This retrospective study included 26 patients with painful prosthesis (THA n = 17; TKA n = 16) and clinical suspicion of periprosthetic loosening, but without a confirmed diagnosis. Patients underwent [68Ga]Ga-DOTAZol PET/CT at least one year post-implantation. Diagnosis was confirmed through revision surgery or long-term clinical follow-up, with an observation period of at least 6 months. The analysis included both an assessment of the prosthesis as a unit and a separate evaluation of the individual components. Statistical analysis involved calculating sensitivity, specificity and accuracy using SPSS.

Results: Overall, a sensitivity of 77.8%, a specificity of 95.8% and an accuracy of 90.9% were found for detecting periprosthetic loosening, when considering the prosthesis as a unit. Individual component analyses showed a sensitivity of 71.4% and specificity of 96.2%.

Conclusion: The use of [68Ga]Ga-DOTAZol PET/CT in periprosthetic loosening is a remarkable diagnostic tool and a promising approach. In comparison to established radionuclide tracers, 68Gallium-Zoledronate offers notable advantages due to its availability via 68Ge/68Ga-generators, improving its potential for clinical application.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用 68Gallium-Zoledronate PET/CT 诊断全髋关节和膝关节假体周围松动。
目的:假体周围松动是全髋关节和膝关节置换术后的主要并发症。早期准确的诊断对于选择正确的治疗方法和避免进一步的并发症至关重要。本研究旨在评估 68Gallium-Zoledronate ([68Ga]Ga-DOTAZol)PET/CT 在检测全髋关节(THA)和全膝关节(TKA)假体周围松动方面的诊断性能:这项回顾性研究纳入了26名假体疼痛的患者(THA n = 17;TKA n = 16),他们临床怀疑存在假体周围松动,但尚未确诊。患者在假体植入后至少一年接受了[68Ga]Ga-DOTAZol PET/CT检查。通过翻修手术或至少 6 个月的长期临床随访来确诊。分析包括对假体整体的评估和对单个组件的单独评估。统计分析包括使用 SPSS 计算灵敏度、特异性和准确性:总体而言,将假体作为一个整体进行评估时,假体周围松动的检测灵敏度为 77.8%,特异度为 95.8%,准确度为 90.9%。单个成分分析显示灵敏度为 71.4%,特异性为 96.2%:结论:在假体周围松动中使用[68Ga]Ga-DOTAZol PET/CT是一种出色的诊断工具,也是一种很有前途的方法。与现有的放射性核素示踪剂相比,68镓-唑膦酸盐具有显著的优势,因为它可以通过68Ge/68Ga发生器获得,从而提高了临床应用的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1