Testing the optical components for the National Ignition Facility time-resolved soft x-ray opacity spectrometer (OpSpecTR).

IF 1.3 4区 工程技术 Q3 INSTRUMENTS & INSTRUMENTATION Review of Scientific Instruments Pub Date : 2024-09-01 DOI:10.1063/5.0218250
M S Wallace, A E Peterson, Y P Opachich, E C Dutra, R A Knight, J M Heinmiller, D M Dzenitis, R Posadas, A G Miller, K Moy, T J Urbatsch, H M Johns, R F Heeter, T S Perry
{"title":"Testing the optical components for the National Ignition Facility time-resolved soft x-ray opacity spectrometer (OpSpecTR).","authors":"M S Wallace, A E Peterson, Y P Opachich, E C Dutra, R A Knight, J M Heinmiller, D M Dzenitis, R Posadas, A G Miller, K Moy, T J Urbatsch, H M Johns, R F Heeter, T S Perry","doi":"10.1063/5.0218250","DOIUrl":null,"url":null,"abstract":"<p><p>Opacity measurements are being carried out at the Z-facility at Sandia National Laboratories and at the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. The current soft x-ray Opacity Spectrometer (OpSpec) used on the NIF uses two elliptically bent crystals in time-integrated mode on either an image plate or a film. Plans are under way to expand these opacity measurements into a mode of time-resolved detection, called OpSpecTR. Previously, considerations for the available hCMOS detector size and photometrics led to a crystal geometry redesign and the use of a grazing angle x-ray mirror. The mirror acts as a low-pass x-ray energy filter, reducing the contribution of higher energy x rays. The first tests of the mirror and the crystal for OpSpecTR are presented here. The size of the mirror reflection and the reflectivity is tested using a Manson x-ray source. The mirror coupled with the new elliptical crystal shape demonstrates OpSpecTR's spectral coverage. The results from the x-ray optics performance testing are shown along with the intended design.</p>","PeriodicalId":21111,"journal":{"name":"Review of Scientific Instruments","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Review of Scientific Instruments","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1063/5.0218250","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

Opacity measurements are being carried out at the Z-facility at Sandia National Laboratories and at the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. The current soft x-ray Opacity Spectrometer (OpSpec) used on the NIF uses two elliptically bent crystals in time-integrated mode on either an image plate or a film. Plans are under way to expand these opacity measurements into a mode of time-resolved detection, called OpSpecTR. Previously, considerations for the available hCMOS detector size and photometrics led to a crystal geometry redesign and the use of a grazing angle x-ray mirror. The mirror acts as a low-pass x-ray energy filter, reducing the contribution of higher energy x rays. The first tests of the mirror and the crystal for OpSpecTR are presented here. The size of the mirror reflection and the reflectivity is tested using a Manson x-ray source. The mirror coupled with the new elliptical crystal shape demonstrates OpSpecTR's spectral coverage. The results from the x-ray optics performance testing are shown along with the intended design.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
测试国家点火装置时间分辨软 X 射线不透明性光谱仪(OpSpecTR)的光学组件。
桑迪亚国家实验室的 Z 设施和劳伦斯-利弗莫尔国家实验室的国家点火装置 (NIF) 正在进行不透明度测量。目前在国家点火装置上使用的软 X 射线不透明度光谱仪(OpSpec)使用两个椭圆弯曲晶体,以时间积分模式在图像板或胶片上进行测量。目前正在计划将这些不透明度测量扩展为一种时间分辨探测模式,称为 OpSpecTR。在此之前,考虑到现有 hCMOS 探测器的尺寸和光度计,对晶体的几何形状进行了重新设计,并使用了掠角 X 射线反射镜。该反射镜起到了低通 X 射线能量滤波器的作用,减少了高能 X 射线的贡献。本文介绍了用于 OpSpecTR 的反射镜和晶体的首次测试。使用曼森 X 射线源测试了反射镜的反射尺寸和反射率。镜面与新的椭圆形晶体形状相结合,展示了 OpSpecTR 的光谱覆盖范围。X 射线光学性能测试结果与预期设计一并显示。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Review of Scientific Instruments
Review of Scientific Instruments 工程技术-物理:应用
CiteScore
3.00
自引率
12.50%
发文量
758
审稿时长
2.6 months
期刊介绍: Review of Scientific Instruments, is committed to the publication of advances in scientific instruments, apparatuses, and techniques. RSI seeks to meet the needs of engineers and scientists in physics, chemistry, and the life sciences.
期刊最新文献
A liquid metal diffusion measurement technique integrating the x-ray radiography and multi-slice sliding cell. Classification of the L-, H-mode, and plasma-free state: Convolutional neural networks and variational autoencoders on the edge reflectometer for KSTAR. Design of a gamma threshold detector based on the bubble chamber for high-flux gamma beams. Development and construction of a cost-effective non-contact instrument for measuring the dielectric constant of liquids. Development of a compact bolometer camera concept for investigation of radiation asymmetries at Wendelstein 7-X.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1