[A retrospective study on two different surgical robots to assist total knee arthroplasty].

Hong-Ping Wang, Ming-You Wang, Zhuo-Dong Tang, Qi-Feng Tao, Yu-Ping Lan
{"title":"[A retrospective study on two different surgical robots to assist total knee arthroplasty].","authors":"Hong-Ping Wang, Ming-You Wang, Zhuo-Dong Tang, Qi-Feng Tao, Yu-Ping Lan","doi":"10.12200/j.issn.1003-0034.20240371","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To compare early clinical and imaging results of domestic HURWA and imported Brainlab Knee3 surgical robot-assisted knee replacement.</p><p><strong>Methods: </strong>A retrospective analysis was performed on 93 patients with knee osteoarthritis (KOA) who underwent robot-assisted descending total knee arthroplasty(TKA) from January 2021 to July 2023, and they were divided into BRATKA group and HRATKA group according to use of robotic system. There were 40 patients in BRATKA group, including 16 males and 24 females, aged from 55 to 90 years old with an average of (64.3±7.0) years old;27 patients with grade Ⅲ and 13 patients with grade Ⅳ according to Kellgren-Lawrence(K-L);18 patients on the right side and 22 patients on the left side;the courses of disease ranged from 1 to 30 years with an average of (15.3±7.6) years;imported Brainlab Knee3 surgical robot assisted system was adopted. There were 53 patients in HRATKA group, including 18 males and 35 females, aged from 52 to 81 years old with an average of (64.4±8.5) years old;30 patients with grade Ⅲ and 23 patients with grade Ⅳ;21 patients on the right side and 32 patients on the left side;the courses of disease ranged from 1 to 32 years with an average of (16.4±7.9) years;HURWA surgical robot assisted system was adopted. Operation time, perioperative total blood loss, incision length and postoperative complications were compared between two groups. Deviation angle of hip-knee-ankle angle(HKAA) before operation and on the first day after operation was compared between two groups. Later tibal component (LTC), frontal femoral component (FFC), later femoral component (LFC) and frontal tibal component(FTC) at 1 day after on the first day after operation was compared between two groups. Knee Society score(KSS), visual analogue scale (VAS) and range of motion (ROM) of knee joint were compared between two groups before operation and on the 3rd and 90th day after operation.</p><p><strong>Results: </strong>Both groups were followed up for 11 to 18 months with an average of (14.4±2.1) months, and the wounds of all patients healed well. Operation time and incision length of BRATKA group were (132.1±34.6) min and (12.9±1.9) cm, while (94.1±10.8) min and (14.8±2.1) cm in HRATKA group, respectively, and the differences between two groups were statistically significant(<i>P</i><0.05). There were no significant difference in perioperative total blood loss and preoperative deviation angle of HKAA between two groups(<i>P</i>>0.05). Deviation angle of HKAA, FFC angle and LFC angle in BRATKA group were (1.90±0.91) °, (87.90±1.51) ° and(9.00±3.2) °, respectively;while (0.93±1.04) °, (89.03±0.96) ° and (7.63±0.59) ° in HRATKA group, respectively, and the differences between two groups were statistically significant (<i>P</i><0.05). There were no significant differences in FTC and LTC between two groups(<i>P</i>>0.05). There were no significant differences in VAS of knee rest and exercise, KSS score and ROM of knee joint between two groups before operation and 3 days and 90 days after operation(<i>P</i>>0.05). There was no significant difference in complications between two groups (<i>P</i>>0.05).</p><p><strong>Conclusion: </strong>Postoperative imaging of two robot systems showed good lower limb force line. The domestic HRATKA group had better LFC, FFC angle and HKA deviation angle than the imported BRATKA group, but there were no significant difference in postoperative knee function and pain relief.</p>","PeriodicalId":23964,"journal":{"name":"Zhongguo gu shang = China journal of orthopaedics and traumatology","volume":"37 9","pages":"870-7"},"PeriodicalIF":0.0000,"publicationDate":"2024-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zhongguo gu shang = China journal of orthopaedics and traumatology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12200/j.issn.1003-0034.20240371","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To compare early clinical and imaging results of domestic HURWA and imported Brainlab Knee3 surgical robot-assisted knee replacement.

Methods: A retrospective analysis was performed on 93 patients with knee osteoarthritis (KOA) who underwent robot-assisted descending total knee arthroplasty(TKA) from January 2021 to July 2023, and they were divided into BRATKA group and HRATKA group according to use of robotic system. There were 40 patients in BRATKA group, including 16 males and 24 females, aged from 55 to 90 years old with an average of (64.3±7.0) years old;27 patients with grade Ⅲ and 13 patients with grade Ⅳ according to Kellgren-Lawrence(K-L);18 patients on the right side and 22 patients on the left side;the courses of disease ranged from 1 to 30 years with an average of (15.3±7.6) years;imported Brainlab Knee3 surgical robot assisted system was adopted. There were 53 patients in HRATKA group, including 18 males and 35 females, aged from 52 to 81 years old with an average of (64.4±8.5) years old;30 patients with grade Ⅲ and 23 patients with grade Ⅳ;21 patients on the right side and 32 patients on the left side;the courses of disease ranged from 1 to 32 years with an average of (16.4±7.9) years;HURWA surgical robot assisted system was adopted. Operation time, perioperative total blood loss, incision length and postoperative complications were compared between two groups. Deviation angle of hip-knee-ankle angle(HKAA) before operation and on the first day after operation was compared between two groups. Later tibal component (LTC), frontal femoral component (FFC), later femoral component (LFC) and frontal tibal component(FTC) at 1 day after on the first day after operation was compared between two groups. Knee Society score(KSS), visual analogue scale (VAS) and range of motion (ROM) of knee joint were compared between two groups before operation and on the 3rd and 90th day after operation.

Results: Both groups were followed up for 11 to 18 months with an average of (14.4±2.1) months, and the wounds of all patients healed well. Operation time and incision length of BRATKA group were (132.1±34.6) min and (12.9±1.9) cm, while (94.1±10.8) min and (14.8±2.1) cm in HRATKA group, respectively, and the differences between two groups were statistically significant(P<0.05). There were no significant difference in perioperative total blood loss and preoperative deviation angle of HKAA between two groups(P>0.05). Deviation angle of HKAA, FFC angle and LFC angle in BRATKA group were (1.90±0.91) °, (87.90±1.51) ° and(9.00±3.2) °, respectively;while (0.93±1.04) °, (89.03±0.96) ° and (7.63±0.59) ° in HRATKA group, respectively, and the differences between two groups were statistically significant (P<0.05). There were no significant differences in FTC and LTC between two groups(P>0.05). There were no significant differences in VAS of knee rest and exercise, KSS score and ROM of knee joint between two groups before operation and 3 days and 90 days after operation(P>0.05). There was no significant difference in complications between two groups (P>0.05).

Conclusion: Postoperative imaging of two robot systems showed good lower limb force line. The domestic HRATKA group had better LFC, FFC angle and HKA deviation angle than the imported BRATKA group, but there were no significant difference in postoperative knee function and pain relief.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[关于两种不同手术机器人辅助全膝关节置换术的回顾性研究]。
目的比较国产HURWA和进口Brainlab Knee3手术机器人辅助膝关节置换的早期临床和影像学结果:方法:对2021年1月至2023年7月期间接受机器人辅助下全膝关节置换术(TKA)的93例膝关节骨性关节炎(KOA)患者进行回顾性分析,根据机器人系统的使用情况分为BRATKA组和HRATKA组。BRATKA组患者40例,其中男性16例,女性24例,年龄55-90岁,平均(64.3±7.0)岁;HRATKA组患者27例,其中男性16例,女性24例,年龄55-90岁,平均(64.3±7.0)岁。0)岁;Kellgren-Lawrence(K-L)分级Ⅲ级27例,Ⅳ级13例;右侧18例,左侧22例;病程1~30年,平均(15.3±7.6)年;采用进口Brainlab Knee3手术机器人辅助系统。HRATKA组患者53例,其中男18例,女35例;年龄52~81岁,平均(64.4±8.5)岁;Ⅲ级患者30例,Ⅳ级患者23例;右侧21例,左侧32例;病程1~32年,平均(16.4±7.9)年;采用HURWA手术机器人辅助系统。比较两组患者的手术时间、围手术期总失血量、切口长度和术后并发症。比较两组患者术前和术后第一天的髋膝踝角度(HKAA)偏差。比较两组术后1天的股骨后端组件(LTC)、股骨前端组件(FFC)、股骨后端组件(LFC)和股骨前端组件(FTC)。比较两组患者术前、术后第3天和第90天的膝关节社会评分(KSS)、视觉模拟量表(VAS)和膝关节活动范围(ROM):两组患者均接受了 11 至 18 个月的随访,平均随访时间为(14.4±2.1)个月,所有患者的伤口愈合良好。BRATKA组的手术时间和切口长度分别为(132.1±34.6)min和(12.9±1.9)cm,HRATKA组分别为(94.1±10.8)min和(14.8±2.1)cm,两组比较差异有统计学意义(PP>0.05)。BRATKA组的HKAA角、FFC角和LFC角偏差分别为(1.90±0.91)°、(87.90±1.51)°和(9.00±3.2)°,而HRATKA组的HKAA角、FFC角和LFC角偏差分别为(0.93±1.04)°、(89.03±0.96)°和(7.63±0.59)°,两组比较差异有统计学意义(PP>0.05)。两组术前、术后3天和90天膝关节休息和运动VAS、KSS评分、膝关节ROM差异无统计学意义(P>0.05)。两组在并发症方面无明显差异(P>0.05):结论:两种机器人系统的术后成像显示下肢力线良好。结论:两种机器人系统的术后成像显示下肢力线良好,国产 HRATKA 组的 LFC、FFC 角和 HKA 偏离角优于进口 BRATKA 组,但在术后膝关节功能和疼痛缓解方面无明显差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.50
自引率
0.00%
发文量
189
期刊最新文献
[Preliminary application of human-computer interaction CT imaging AI recognition and positioning technology in the treatment of type C1 distal radius fractures]. [Guiding significance of intra-articular sagittal reduction in the treatment of tibial plateau fractures]. [Meta-analysis of the efficacy of plate fixation and external fixator fixation in the treatment of AO-C type distal radius fractures]. [Preoperative diagnostic efficacy of novel blood markers white blood cell ratio and fibrinogen levels in periprosthetic joint infection]. [Short-term clinical efficacy of unilateral external fixator combined with percutaneous Kirschner wire fixation in the treatment of type C1 distal radius fractures in elderly patients].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1