Comparison of analytical-flow, micro-flow and nano-flow LC-MS/MS for sub-proteome analysis

IF 3.1 3区 医学 Q2 CHEMISTRY, ANALYTICAL Journal of pharmaceutical and biomedical analysis Pub Date : 2024-09-27 DOI:10.1016/j.jpba.2024.116484
Zhen Long , Zixi Zhao , Xingliang Fan , Xi Luo
{"title":"Comparison of analytical-flow, micro-flow and nano-flow LC-MS/MS for sub-proteome analysis","authors":"Zhen Long ,&nbsp;Zixi Zhao ,&nbsp;Xingliang Fan ,&nbsp;Xi Luo","doi":"10.1016/j.jpba.2024.116484","DOIUrl":null,"url":null,"abstract":"<div><div>The accurate and sensitive analysis of sub-proteomic samples, such as host cell proteins (HCPs) in recombinant products and stem cells in medical devices, is crucial for ensuring product safety and efficacy in the biopharmaceutical industry. However, current analytical techniques, such as conventional analytical-flow LC-MS/MS, face limitations in sensitivity due to the low concentrations of target proteins and the complexity of the sample matrix. In this study, a highly sensitive and repeatable micro-flow LC-MS/MS strategy was developed by replacing analytical-flow tubing with micro-flow tubing on an existing analytical-flow LC-MS system for sub-proteomic sample analysis. Method optimization and evaluation were first conducted with monoclonal antibody (mAb) digestion, focusing on enhancing sensitivity and repeatability. Over 8 days, relative standard deviations (RSDs) for retention time and mass area were less than 5 % and 10 %, respectively. Sensitivity improved by 2.91–4.14 times compared to the analytical-flow LC-MS/MS method. After confirming the reliability of the method, the micro-flow LC-MS/MS method was compared to the nano-flow LC-MS/MS method and the analytical-flow LC-MS/MS method in sub-proteomic sample analysis. For HCPs, the micro-flow LC-MS/MS method demonstrated superior qualitative and much better reproducibility than the nano-flow LC-MS/MS method, with more than 98 % of proteins showing intensity RSD values below 20 %. In the analysis of mesenchymal stem cells (MSCs), the micro-flow method demonstrated good reproducibility and better sensitivity than the analytical-flow method. Taking the analysis of the 20<sup>th</sup> generation of MSC products as an example, the sample analyzed by micro-flow LC-MS/MS resulted in the identification of 68 % and 8.5 % more peptides and proteins, respectively. Moreover, micro-flow maintained stable system pressure while analyzing umbilical cord stem cells, where nano-flow methods often encounter blockages. This micro-flow LC-MS/MS method is notable for its sensitivity, reproducibility, and straightforward operation, making it highly adaptable for diverse sub-proteomic analyses in biopharmaceutical laboratories.</div></div>","PeriodicalId":16685,"journal":{"name":"Journal of pharmaceutical and biomedical analysis","volume":"252 ","pages":"Article 116484"},"PeriodicalIF":3.1000,"publicationDate":"2024-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of pharmaceutical and biomedical analysis","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0731708524005260","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The accurate and sensitive analysis of sub-proteomic samples, such as host cell proteins (HCPs) in recombinant products and stem cells in medical devices, is crucial for ensuring product safety and efficacy in the biopharmaceutical industry. However, current analytical techniques, such as conventional analytical-flow LC-MS/MS, face limitations in sensitivity due to the low concentrations of target proteins and the complexity of the sample matrix. In this study, a highly sensitive and repeatable micro-flow LC-MS/MS strategy was developed by replacing analytical-flow tubing with micro-flow tubing on an existing analytical-flow LC-MS system for sub-proteomic sample analysis. Method optimization and evaluation were first conducted with monoclonal antibody (mAb) digestion, focusing on enhancing sensitivity and repeatability. Over 8 days, relative standard deviations (RSDs) for retention time and mass area were less than 5 % and 10 %, respectively. Sensitivity improved by 2.91–4.14 times compared to the analytical-flow LC-MS/MS method. After confirming the reliability of the method, the micro-flow LC-MS/MS method was compared to the nano-flow LC-MS/MS method and the analytical-flow LC-MS/MS method in sub-proteomic sample analysis. For HCPs, the micro-flow LC-MS/MS method demonstrated superior qualitative and much better reproducibility than the nano-flow LC-MS/MS method, with more than 98 % of proteins showing intensity RSD values below 20 %. In the analysis of mesenchymal stem cells (MSCs), the micro-flow method demonstrated good reproducibility and better sensitivity than the analytical-flow method. Taking the analysis of the 20th generation of MSC products as an example, the sample analyzed by micro-flow LC-MS/MS resulted in the identification of 68 % and 8.5 % more peptides and proteins, respectively. Moreover, micro-flow maintained stable system pressure while analyzing umbilical cord stem cells, where nano-flow methods often encounter blockages. This micro-flow LC-MS/MS method is notable for its sensitivity, reproducibility, and straightforward operation, making it highly adaptable for diverse sub-proteomic analyses in biopharmaceutical laboratories.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于亚蛋白质组分析的分析流、微流和纳米流 LC-MS/MS 的比较
准确灵敏地分析亚蛋白质组样品,如重组产品中的宿主细胞蛋白质(HCP)和医疗器械中的干细胞,对于确保生物制药行业产品的安全性和有效性至关重要。然而,目前的分析技术,如传统的分析流式 LC-MS/MS,由于目标蛋白质浓度低、样品基质复杂,在灵敏度方面存在局限性。本研究开发了一种高灵敏度和可重复性的微流 LC-MS/MS 策略,在现有的分析流 LC-MS 系统上用微流管取代分析流管,用于亚蛋白质组样品分析。首先用单克隆抗体(mAb)消化法进行了方法优化和评估,重点是提高灵敏度和可重复性。在 8 天内,保留时间和质量面积的相对标准偏差(RSD)分别小于 5 % 和 10 %。与分析流式 LC-MS/MS 方法相比,灵敏度提高了 2.91-4.14 倍。在确认了方法的可靠性之后,微流 LC-MS/MS 方法与纳米流 LC-MS/MS 方法和分析流 LC-MS/MS 方法在亚蛋白质组样品分析中进行了比较。就 HCPs 而言,微流 LC-MS/MS 方法比纳米流 LC-MS/MS 方法具有更高的定性和重现性,98% 以上的蛋白质强度 RSD 值低于 20%。在间充质干细胞(MSCs)分析中,微流方法比分析流方法表现出良好的重现性和更高的灵敏度。以分析第 20 代间充质干细胞产品为例,采用微流 LC-MS/MS 分析的样品多肽和蛋白质的鉴定率分别提高了 68% 和 8.5%。此外,微流在分析脐带干细胞时能保持稳定的系统压力,而纳米流方法经常会遇到阻塞。这种微流 LC-MS/MS 方法灵敏度高、重现性好、操作简单,非常适合生物制药实验室进行各种亚蛋白质组分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
6.70
自引率
5.90%
发文量
588
审稿时长
37 days
期刊介绍: This journal is an international medium directed towards the needs of academic, clinical, government and industrial analysis by publishing original research reports and critical reviews on pharmaceutical and biomedical analysis. It covers the interdisciplinary aspects of analysis in the pharmaceutical, biomedical and clinical sciences, including developments in analytical methodology, instrumentation, computation and interpretation. Submissions on novel applications focusing on drug purity and stability studies, pharmacokinetics, therapeutic monitoring, metabolic profiling; drug-related aspects of analytical biochemistry and forensic toxicology; quality assurance in the pharmaceutical industry are also welcome. Studies from areas of well established and poorly selective methods, such as UV-VIS spectrophotometry (including derivative and multi-wavelength measurements), basic electroanalytical (potentiometric, polarographic and voltammetric) methods, fluorimetry, flow-injection analysis, etc. are accepted for publication in exceptional cases only, if a unique and substantial advantage over presently known systems is demonstrated. The same applies to the assay of simple drug formulations by any kind of methods and the determination of drugs in biological samples based merely on spiked samples. Drug purity/stability studies should contain information on the structure elucidation of the impurities/degradants.
期刊最新文献
Proteomics exploration of metformin hydrochloride for diabetic kidney disease treatment via the butanoate metabolism pathway A multi-band spectral data fusion method for improving the accuracy of quantitative spectral analysis Feasibility of a direct binding electrochemiluminescence assay to detect anti-drug antibodies against therapeutic peptides Nitrogen dioxide sterilization of a set of five ophthalmic active pharmaceutical ingredients: Impact on impurity profile and content Determination of sacubitril and seven sartan drugs in serum samples by online solid phase extraction-liquid chromatography-tandem mass spectrometry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1