{"title":"Acquisition and reconstruction with motion suppression DWI enhance image quality in nasopharyngeal carcinoma patients: Non-echo-planar DWI comparison with single-shot echo-planar DWI","authors":"Guixiao Xu ,&nbsp;Haibin Liu ,&nbsp;Dingwei Ling ,&nbsp;Yu Li ,&nbsp;Nian Lu ,&nbsp;Xinyang Li ,&nbsp;Yezhuo Zhang ,&nbsp;Haoqiang He ,&nbsp;Zuhe Huang ,&nbsp;Chuanmiao Xie","doi":"10.1016/j.ejrad.2024.111752","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><div>To evaluate the impact of application acquisition and reconstruction with motion suppression (ARMS) technology on improving the image quality of diffusion-weighted Imaging (DWI) for nasopharyngeal carcinoma (NPC), compared to single-shot echo-planar imaging (SS-EPI).</div></div><div><h3>Methods</h3><div>A total of 90 patients with NPC underwent MR examination, including ARMS DWI and SS-EPI DWI sequences. Both DWI sequences were acquired with b-values 0 and 800 s/mm<sup>2</sup>. Two radiologists evaluated the visibility of the lesion, geometric distortion, and overall image quality of the two DWI sequences. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), geometric distortion degree, and apparent diffusion coefficient (ADC) values of the nasopharyngeal lesions were assessed and compared for two sequences. The Wilcoxon signed-rank test was used to compare the quantitative and qualitative parameters of the two sequences.</div></div><div><h3>Results</h3><div>The lesion visibility, geometric distortion, and overall image quality scores were significantly higher in ARMS DWI (all P&lt;0.001). Four small-sized lesions were not visible and four lesions were partially visible in the SS-EPI DWI sequence. Lesion detection rate of ARMS DWI is 100 %, while that of SS-EPI is 95.56 %, P&lt;0.043. The mismatch distance between the fusion images of ARMS DWI and T2WI was smaller than that of SS-EPI DWI and T2WI (all P&lt;0.001). The SNR and CNR of ARMS DWI were lower than that of SS-EPI DWI (114.48 ± 37.89 vs. 202.61 ± 78.84, P&lt;0.001 and 1.81 ± 1.84 vs. 3.29 ± 3.71, P&lt;0.003) while the ADC value was higher (839.19 ± 138.44 × 10<sup>−6</sup> mm<sup>2</sup>/s vs. 788.82 ± 110.96 × 10<sup>−6</sup> mm<sup>2</sup>/s, P&lt;0.002).</div></div><div><h3>Conclusion</h3><div>ARMS DWI improves the image quality by reducing geometric distortion and magnetic susceptibility artifacts. ARMS DWI is superior to SS-EPI DWI for diagnosing small-sized nasopharyngeal lesions, although it has lower SNR and CNR.</div></div>","PeriodicalId":12063,"journal":{"name":"European Journal of Radiology","volume":"181 ","pages":"Article 111752"},"PeriodicalIF":3.2000,"publicationDate":"2024-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Radiology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0720048X24004686","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

To evaluate the impact of application acquisition and reconstruction with motion suppression (ARMS) technology on improving the image quality of diffusion-weighted Imaging (DWI) for nasopharyngeal carcinoma (NPC), compared to single-shot echo-planar imaging (SS-EPI).

Methods

A total of 90 patients with NPC underwent MR examination, including ARMS DWI and SS-EPI DWI sequences. Both DWI sequences were acquired with b-values 0 and 800 s/mm2. Two radiologists evaluated the visibility of the lesion, geometric distortion, and overall image quality of the two DWI sequences. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), geometric distortion degree, and apparent diffusion coefficient (ADC) values of the nasopharyngeal lesions were assessed and compared for two sequences. The Wilcoxon signed-rank test was used to compare the quantitative and qualitative parameters of the two sequences.

Results

The lesion visibility, geometric distortion, and overall image quality scores were significantly higher in ARMS DWI (all P<0.001). Four small-sized lesions were not visible and four lesions were partially visible in the SS-EPI DWI sequence. Lesion detection rate of ARMS DWI is 100 %, while that of SS-EPI is 95.56 %, P<0.043. The mismatch distance between the fusion images of ARMS DWI and T2WI was smaller than that of SS-EPI DWI and T2WI (all P<0.001). The SNR and CNR of ARMS DWI were lower than that of SS-EPI DWI (114.48 ± 37.89 vs. 202.61 ± 78.84, P<0.001 and 1.81 ± 1.84 vs. 3.29 ± 3.71, P<0.003) while the ADC value was higher (839.19 ± 138.44 × 10−6 mm2/s vs. 788.82 ± 110.96 × 10−6 mm2/s, P<0.002).

Conclusion

ARMS DWI improves the image quality by reducing geometric distortion and magnetic susceptibility artifacts. ARMS DWI is superior to SS-EPI DWI for diagnosing small-sized nasopharyngeal lesions, although it has lower SNR and CNR.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用运动抑制 DWI 进行采集和重建可提高鼻咽癌患者的图像质量:非回声平面 DWI 与单次回声平面 DWI 的比较
目的与单次回声平面成像(SS-EPI)相比,评估应用运动抑制采集和重建(ARMS)技术对提高鼻咽癌(NPC)弥散加权成像(DWI)图像质量的影响。两种 DWI 序列的 b 值分别为 0 和 800 s/mm2。两名放射科医生对病变的可见度、几何失真以及两个 DWI 序列的整体图像质量进行了评估。评估并比较了两种序列的信噪比(SNR)、对比度-信噪比(CNR)、几何失真度和鼻咽病变的表观弥散系数(ADC)值。结果 ARMS DWI 的病变可见度、几何失真度和总体图像质量评分明显更高(均为 P<0.001)。在 SS-EPI DWI 序列中,4 个小病灶不可见,4 个病灶部分可见。ARMS DWI 的病灶检出率为 100%,而 SS-EPI 为 95.56%,P<0.043。ARMS DWI 与 T2WI 融合图像的不匹配距离小于 SS-EPI DWI 与 T2WI 融合图像的不匹配距离(均为 P<0.001)。ARMS DWI 的 SNR 和 CNR 低于 SS-EPI DWI(114.48 ± 37.89 vs. 202.61 ± 78.84,P<0.001 和 1.81 ± 1.84 vs. 3.29 ± 3.71,P<0.003),而 ADC 值却高于 SS-EPI DWI(839.19±138.44×10-6mm2/s对788.82±110.96×10-6mm2/s,P<0.002)。结论ARMS DWI通过减少几何失真和磁感应伪影提高了图像质量。ARMS DWI 在诊断小尺寸鼻咽病变方面优于 SS-EPI DWI,尽管其信噪比和 CNR 较低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
6.70
自引率
3.00%
发文量
398
审稿时长
42 days
期刊介绍: European Journal of Radiology is an international journal which aims to communicate to its readers, state-of-the-art information on imaging developments in the form of high quality original research articles and timely reviews on current developments in the field. Its audience includes clinicians at all levels of training including radiology trainees, newly qualified imaging specialists and the experienced radiologist. Its aim is to inform efficient, appropriate and evidence-based imaging practice to the benefit of patients worldwide.
期刊最新文献
Multilingual feasibility of GPT-4o for automated Voice-to-Text CT and MRI report transcription. Predicting functional outcome after open lumbar fusion surgery: A retrospective multicenter cohort study ECG, clinical and novel CT-imaging predictors of necessary pacemaker implantation after transfemoral aortic valve replacement In-vivo cerebral artery pulsation assessment with Dynamic computed tomography angiography Diagnostic performance of Photon-counting CT angiography in peripheral artery disease compared to DSA as gold standard
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1