Design and Fabrication of a Metal Resistance Strain Sensor With Enhanced Sensitivity

IF 2.2 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC IEEE Sensors Letters Pub Date : 2024-09-13 DOI:10.1109/LSENS.2024.3460399
Roberto S. Aga;Lemuel Duncan;Laura Davidson;Fahima Ouchen;Rachel Aga;Emily M. Heckman;Carrie M. Bartsch
{"title":"Design and Fabrication of a Metal Resistance Strain Sensor With Enhanced Sensitivity","authors":"Roberto S. Aga;Lemuel Duncan;Laura Davidson;Fahima Ouchen;Rachel Aga;Emily M. Heckman;Carrie M. Bartsch","doi":"10.1109/LSENS.2024.3460399","DOIUrl":null,"url":null,"abstract":"This letter reports a novel design of a resistance strain sensor and its method of fabrication. The sensor is made of printed silver (Ag), but its sensitivity, which is measured by the gauge factor (GF), surpasses most commercial metal foil strain gauges (COTS). These COTS have a low GF (∼2) because they exhibit a weak piezoresistive effect. As a result, their sensitivity is dominated by the geometric effect. In this design, the GF is not limited by the weak piezoresistive effect in Ag. Its enhanced sensitivity (GF∼55) originates from the junctions that are created when a conductive cross-pattern is laser sintered on a printed Ag pad. The cross-pattern consists of a low-resistivity vertical trace and a high-resistivity horizontal trace. The difference in resistivity is achieved by changing the laser sintering power. The junction that joins the high and the low resistivity traces is a boundary with interfacial resistance. This interfacial resistance exhibits high sensitivity to strain leading to a different design and fabrication of a resistance strain sensor.","PeriodicalId":13014,"journal":{"name":"IEEE Sensors Letters","volume":"8 10","pages":"1-4"},"PeriodicalIF":2.2000,"publicationDate":"2024-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Sensors Letters","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10679709/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

This letter reports a novel design of a resistance strain sensor and its method of fabrication. The sensor is made of printed silver (Ag), but its sensitivity, which is measured by the gauge factor (GF), surpasses most commercial metal foil strain gauges (COTS). These COTS have a low GF (∼2) because they exhibit a weak piezoresistive effect. As a result, their sensitivity is dominated by the geometric effect. In this design, the GF is not limited by the weak piezoresistive effect in Ag. Its enhanced sensitivity (GF∼55) originates from the junctions that are created when a conductive cross-pattern is laser sintered on a printed Ag pad. The cross-pattern consists of a low-resistivity vertical trace and a high-resistivity horizontal trace. The difference in resistivity is achieved by changing the laser sintering power. The junction that joins the high and the low resistivity traces is a boundary with interfacial resistance. This interfacial resistance exhibits high sensitivity to strain leading to a different design and fabrication of a resistance strain sensor.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
设计和制造灵敏度更高的金属电阻应变传感器
这封信报告了电阻应变传感器的新型设计及其制造方法。该传感器由印刷银(Ag)制成,但其灵敏度(通过量规系数(GF)测量)超过了大多数商用金属箔应变片(COTS)。这些 COTS 的 GF 值(∼2)很低,因为它们的压阻效应很弱。因此,它们的灵敏度主要受几何效应的影响。在这种设计中,GF 不受 Ag 中弱压阻效应的限制。其更高的灵敏度(GF∼55)源于在印刷的银垫上激光烧结导电交叉图案时产生的结点。交叉图案由一条低电阻率垂直轨迹和一条高电阻率水平轨迹组成。电阻率的差异是通过改变激光烧结功率来实现的。连接高电阻率和低电阻率轨迹的交界处是具有界面电阻的边界。这种界面电阻对应变的敏感度很高,因此需要设计和制造不同的电阻应变传感器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
IEEE Sensors Letters
IEEE Sensors Letters Engineering-Electrical and Electronic Engineering
CiteScore
3.50
自引率
7.10%
发文量
194
期刊最新文献
PPY-fMWCNT Nanocomposite-Based Chemicapacitive Biosensor for Ultrasensitive Detection of TBI-Specific GFAP Biomarker in Human Plasma Front Cover IEEE Sensors Council Information Table of Contents IEEE Sensors Letters Subject Categories for Article Numbering Information
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1