Four-dimensional (4D) Ultrasound Shear Wave Elastography Using Sequential Excitation.

IF 4.4 2区 医学 Q2 ENGINEERING, BIOMEDICAL IEEE Transactions on Biomedical Engineering Pub Date : 2024-10-02 DOI:10.1109/TBME.2024.3472689
Xin Sun, Chi-Feng Chang, Junhang Zhang, Yushun Zeng, Bitong Li, Yizhe Sun, Haochen Kang, Hsiao-Chuan Liu, Qifa Zhou
{"title":"Four-dimensional (4D) Ultrasound Shear Wave Elastography Using Sequential Excitation.","authors":"Xin Sun, Chi-Feng Chang, Junhang Zhang, Yushun Zeng, Bitong Li, Yizhe Sun, Haochen Kang, Hsiao-Chuan Liu, Qifa Zhou","doi":"10.1109/TBME.2024.3472689","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Current shear wave elastography methods primarily focus on 2D imaging. To explore mechanical properties of biological tissues in 3D, a four-dimensional (4D, x, y, z, t) ultrasound shear wave elastography is required. However, 4D ultrasound shear wave elastography is still challenging due to the limitation of the hardware of standard ultrasound acquisition systems. In this study, we introduce a novel method to achieve 4D shear wave elastography, named sequential-based excitation shear wave elastography (SE-SWE). This method can achieve 4D elastography implemented by a 1024-element 2D array with a standard ultrasound 256-channel system.</p><p><strong>Methods: </strong>The SE-SWE method employs sequential excitation to generate shear waves, and utilizes a 2D array, dividing it into four sub-sections, to capture shear waves across multiple planes. This process involves sequentially exciting each sub-section to capture shear waves, followed by compounding the acquired data from these subsections.</p><p><strong>Results: </strong>The phantom studies showed strong concordance between the shear wave speeds (SWS) measured by SE-SWE and expected values, confirming the accuracy of this method and potential to differentiate tissues by stiffness. In ex vivo chicken breast experiments, SE-SWE effectively distinguished between orientations relative to muscle fibers, highlighting its ability to capture the anisotropic properties of tissues.</p><p><strong>Conclusion: </strong>The SE-SWE method advances shear wave elastography significantly by using a 2D array divided into four subsections and sequential excitation, achieving high-resolution volumetric imaging at 1.6mm resolution.</p><p><strong>Significance: </strong>The SE-SWE method offers a straightforward and effective approach for 3D shear volume imaging of tissue biological properties.</p>","PeriodicalId":13245,"journal":{"name":"IEEE Transactions on Biomedical Engineering","volume":null,"pages":null},"PeriodicalIF":4.4000,"publicationDate":"2024-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1109/TBME.2024.3472689","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Current shear wave elastography methods primarily focus on 2D imaging. To explore mechanical properties of biological tissues in 3D, a four-dimensional (4D, x, y, z, t) ultrasound shear wave elastography is required. However, 4D ultrasound shear wave elastography is still challenging due to the limitation of the hardware of standard ultrasound acquisition systems. In this study, we introduce a novel method to achieve 4D shear wave elastography, named sequential-based excitation shear wave elastography (SE-SWE). This method can achieve 4D elastography implemented by a 1024-element 2D array with a standard ultrasound 256-channel system.

Methods: The SE-SWE method employs sequential excitation to generate shear waves, and utilizes a 2D array, dividing it into four sub-sections, to capture shear waves across multiple planes. This process involves sequentially exciting each sub-section to capture shear waves, followed by compounding the acquired data from these subsections.

Results: The phantom studies showed strong concordance between the shear wave speeds (SWS) measured by SE-SWE and expected values, confirming the accuracy of this method and potential to differentiate tissues by stiffness. In ex vivo chicken breast experiments, SE-SWE effectively distinguished between orientations relative to muscle fibers, highlighting its ability to capture the anisotropic properties of tissues.

Conclusion: The SE-SWE method advances shear wave elastography significantly by using a 2D array divided into four subsections and sequential excitation, achieving high-resolution volumetric imaging at 1.6mm resolution.

Significance: The SE-SWE method offers a straightforward and effective approach for 3D shear volume imaging of tissue biological properties.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用序列激励的四维 (4D) 超声剪切波弹性成像。
目的:目前的剪切波弹性成像方法主要侧重于二维成像。要探索生物组织的三维机械特性,需要四维(4D, x, y, z, t)超声剪切波弹性成像。然而,由于标准超声采集系统硬件的限制,4D 超声剪切波弹性成像仍然具有挑战性。在本研究中,我们介绍了一种实现四维剪切波弹性成像的新方法,命名为基于序列激发的剪切波弹性成像(SE-SWE)。该方法可通过标准超声 256 通道系统的 1024 元二维阵列实现 4D 弹性成像:SE-SWE方法采用顺序激发法产生剪切波,并利用二维阵列将其分为四个分区,以捕捉多个平面上的剪切波。这一过程包括依次激发每个子截面以捕捉剪切波,然后将从这些子截面获取的数据进行复合:结果:模型研究显示,SE-SWE 测得的剪切波速度(SWS)与预期值非常一致,证实了这种方法的准确性以及根据硬度区分组织的潜力。在活体鸡胸实验中,SE-SWE 能有效区分相对于肌肉纤维的取向,突出了其捕捉组织各向异性的能力:结论:SE-SWE 方法通过使用分为四个分区的二维阵列和顺序激发,实现了 1.6 毫米分辨率的高分辨率容积成像,从而大大推进了剪切波弹性成像技术的发展:意义:SE-SWE 方法为组织生物特性的三维剪切容积成像提供了一种简单有效的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
IEEE Transactions on Biomedical Engineering
IEEE Transactions on Biomedical Engineering 工程技术-工程:生物医学
CiteScore
9.40
自引率
4.30%
发文量
880
审稿时长
2.5 months
期刊介绍: IEEE Transactions on Biomedical Engineering contains basic and applied papers dealing with biomedical engineering. Papers range from engineering development in methods and techniques with biomedical applications to experimental and clinical investigations with engineering contributions.
期刊最新文献
TFTL: A Task-Free Transfer Learning Strategy for EEG-based Cross-Subject & Cross-Dataset Motor Imagery BCI. Robotic Fast Dual-Arm Patch Clamp System for Mechanosensitive Excitability Research of Neurons. Four-dimensional (4D) Ultrasound Shear Wave Elastography Using Sequential Excitation. Cervical Collagen Network Porosity Assessed by SHG Endomicroscopy Distinguishes Preterm and Normal Pregnancy - a Pilot Study. Main Coronary Flow Calculation With the Assistance of Physiological Side Branch Flow.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1