Omar Mourad Hassan Zaki Selim , Ahmed Samir Abdel Hakim Ibrahim , Nihal Hussien Aly , Sherif Nabil Abbas Hegazy , Fatma Soliman Elsayed Ebeid
{"title":"Early detection of myocardial iron overload in patients with β-thalassemia major using cardiac magnetic resonance T1 mapping","authors":"Omar Mourad Hassan Zaki Selim , Ahmed Samir Abdel Hakim Ibrahim , Nihal Hussien Aly , Sherif Nabil Abbas Hegazy , Fatma Soliman Elsayed Ebeid","doi":"10.1016/j.mri.2024.110250","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>The T2* technique, used for quantifying myocardial iron content (MIC), has limitations in detecting early myocardial iron overload (MIO). The in vivo mapping of the myocardial T1 relaxation time is a promising alternative for the early detection and management of MIO.</div></div><div><h3>Methods</h3><div>32 β-thalassemia major (βTM) patients aged 11.5 ± 4 years and 32 healthy controls were recruited and underwent thorough clinical and laboratory assessments. The mid-level septal iron overload was measured through T1 mapping using a modified Look-Locker inversion recovery sequence with a 3 (3 s) 3 (3 s) 5 scheme. Septum was divided at the mentioned level into 3 zones corresponding to segments 8 and 9 in the cardiac segmentation model.</div></div><div><h3>Results</h3><div>21.9 % of βTM had clinical cardiac morbidity. The cut-off of T1 mapping of hepatic and myocardium to differentiate between the patients and control groups was ≤466 and ≥ 923 ms respectively. The T1 technique was able to detect 4 patients with high MIC, two of them were not detected by the T2* technique. There was a statistically significant correlation between the average T1 values of the studied zones in patients with βTM and the liver iron content (LIC), the T1 values within segment 8 of the liver, age of patients, the age at first transfusion, age of splenectomy and serum ferritin value.</div></div><div><h3>Conclusion</h3><div>The addition of the T1 mapping sequence to the conventional T2* technique was able to increase the efficacy of the MIC detection protocol by earlier detection of MIO. This would guide chelation therapy to decrease myocardial morbidity.</div></div>","PeriodicalId":18165,"journal":{"name":"Magnetic resonance imaging","volume":"114 ","pages":"Article 110250"},"PeriodicalIF":2.1000,"publicationDate":"2024-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic resonance imaging","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0730725X24002315","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Background
The T2* technique, used for quantifying myocardial iron content (MIC), has limitations in detecting early myocardial iron overload (MIO). The in vivo mapping of the myocardial T1 relaxation time is a promising alternative for the early detection and management of MIO.
Methods
32 β-thalassemia major (βTM) patients aged 11.5 ± 4 years and 32 healthy controls were recruited and underwent thorough clinical and laboratory assessments. The mid-level septal iron overload was measured through T1 mapping using a modified Look-Locker inversion recovery sequence with a 3 (3 s) 3 (3 s) 5 scheme. Septum was divided at the mentioned level into 3 zones corresponding to segments 8 and 9 in the cardiac segmentation model.
Results
21.9 % of βTM had clinical cardiac morbidity. The cut-off of T1 mapping of hepatic and myocardium to differentiate between the patients and control groups was ≤466 and ≥ 923 ms respectively. The T1 technique was able to detect 4 patients with high MIC, two of them were not detected by the T2* technique. There was a statistically significant correlation between the average T1 values of the studied zones in patients with βTM and the liver iron content (LIC), the T1 values within segment 8 of the liver, age of patients, the age at first transfusion, age of splenectomy and serum ferritin value.
Conclusion
The addition of the T1 mapping sequence to the conventional T2* technique was able to increase the efficacy of the MIC detection protocol by earlier detection of MIO. This would guide chelation therapy to decrease myocardial morbidity.
期刊介绍:
Magnetic Resonance Imaging (MRI) is the first international multidisciplinary journal encompassing physical, life, and clinical science investigations as they relate to the development and use of magnetic resonance imaging. MRI is dedicated to both basic research, technological innovation and applications, providing a single forum for communication among radiologists, physicists, chemists, biochemists, biologists, engineers, internists, pathologists, physiologists, computer scientists, and mathematicians.