Development and validation of a stability-indicating HPLC method for assay of tonabersat in pharmaceutical formulations

IF 4.2 3区 生物学 Q1 BIOCHEMICAL RESEARCH METHODS Methods Pub Date : 2024-10-03 DOI:10.1016/j.ymeth.2024.10.001
Santosh Bhujbal, Ilva D. Rupenthal, Priyanka Agarwal
{"title":"Development and validation of a stability-indicating HPLC method for assay of tonabersat in pharmaceutical formulations","authors":"Santosh Bhujbal,&nbsp;Ilva D. Rupenthal,&nbsp;Priyanka Agarwal","doi":"10.1016/j.ymeth.2024.10.001","DOIUrl":null,"url":null,"abstract":"<div><div>A stability-indicating reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed to assay tonabersat and assess its stability in pharmaceutical formulations. Chromatographic separation was achieved using a Kinetex® C18 column (2.6 µm, 150 x 3 mm, 100 Å) at 50 °C, with a 20 µL injection volume. A linear gradient of acetonitrile in water (5 – 33.5 %) was applied for 1 min, followed by a gradual increase to 100 % over 26 min at a flow rate of 0.5 mL/min. Tonabersat and its degradation products were detected at 275 nm and 210 nm, respectively. The optimized method was used to evaluate the stability of tonabersat in lipid-based pharmaceutical formulations at 5 ± 3 °C, 25 ± 2°C/60 ± 5 % RH, and 40 ± 2 °C/75 ± 5 % RH over 3 months. The method was validated as per ICH guidelines and demonstrated linearity in the range of 5 – 200 µg/mL (R<sup>2</sup> = 0.99994) with good accuracy (98.25 – 101.58 % recovery) and precision (% RSD &lt; 2.5 %). The limits of detection and quantitation were 0.8 µg/mL and 5 µg/mL, respectively. Forced degradation studies showed significant degradation on exposure to alkaline (90.33 ± 0.80 %), acidic (70.60 ± 1.57 %), and oxidative stress (33.95 ± 0.69 %) at 70 °C, but no degradation was observed on exposure to thermal or photolytic stress. No chemical degradation was observed in either formulation on storage. Thus, the method was sensitive, specific, and suitable for stability testing of tonabersat in pharmaceutical formulations.</div></div>","PeriodicalId":390,"journal":{"name":"Methods","volume":"231 ","pages":"Pages 178-185"},"PeriodicalIF":4.2000,"publicationDate":"2024-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Methods","FirstCategoryId":"99","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1046202324002184","RegionNum":3,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

A stability-indicating reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed to assay tonabersat and assess its stability in pharmaceutical formulations. Chromatographic separation was achieved using a Kinetex® C18 column (2.6 µm, 150 x 3 mm, 100 Å) at 50 °C, with a 20 µL injection volume. A linear gradient of acetonitrile in water (5 – 33.5 %) was applied for 1 min, followed by a gradual increase to 100 % over 26 min at a flow rate of 0.5 mL/min. Tonabersat and its degradation products were detected at 275 nm and 210 nm, respectively. The optimized method was used to evaluate the stability of tonabersat in lipid-based pharmaceutical formulations at 5 ± 3 °C, 25 ± 2°C/60 ± 5 % RH, and 40 ± 2 °C/75 ± 5 % RH over 3 months. The method was validated as per ICH guidelines and demonstrated linearity in the range of 5 – 200 µg/mL (R2 = 0.99994) with good accuracy (98.25 – 101.58 % recovery) and precision (% RSD < 2.5 %). The limits of detection and quantitation were 0.8 µg/mL and 5 µg/mL, respectively. Forced degradation studies showed significant degradation on exposure to alkaline (90.33 ± 0.80 %), acidic (70.60 ± 1.57 %), and oxidative stress (33.95 ± 0.69 %) at 70 °C, but no degradation was observed on exposure to thermal or photolytic stress. No chemical degradation was observed in either formulation on storage. Thus, the method was sensitive, specific, and suitable for stability testing of tonabersat in pharmaceutical formulations.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
开发和验证用于检测药物制剂中托那酯的稳定性指示高效液相色谱法。
本研究开发了一种稳定性指示反相高效液相色谱法(RP-HPLC),用于检测托那酯并评估其在药物制剂中的稳定性。色谱分离采用 Kinetex® C18 色谱柱(2.6 µm,150 x 3 mm,100 Å),温度为 50 °C,进样量为 20 µL。乙腈水溶液(5 - 33.5%)的线性梯度为 1 分钟,然后在 26 分钟内逐渐升至 100%,流速为 0.5 mL/min。在 275 纳米和 210 纳米波长下分别检测托那伯沙特及其降解产物。采用优化后的方法评估了托那伯沙特在脂质药物制剂中 5 ± 3 °C、25 ± 2 °C/60 ± 5 % 相对湿度和 40 ± 2 °C/75 ± 5 % 相对湿度条件下 3 个月的稳定性。该方法按照 ICH 指南进行了验证,在 5 - 200 µg/mL 范围内线性关系良好(R2 = 0.99994),准确度(回收率 98.25 - 101.58 %)和精密度(RSD < 2.5 %)良好。检测和定量限分别为 0.8 µg/mL 和 5 µg/mL。强制降解研究表明,在 70 °C的碱性(90.33 ± 0.80 %)、酸性(70.60 ± 1.57 %)和氧化应激(33.95 ± 0.69 %)条件下会出现明显降解,但在热应激或光解应激条件下未观察到降解。两种制剂在储存过程中均未出现化学降解。因此,该方法灵敏、特异,适用于药物制剂中托那酯稳定性的检测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Methods
Methods 生物-生化研究方法
CiteScore
9.80
自引率
2.10%
发文量
222
审稿时长
11.3 weeks
期刊介绍: Methods focuses on rapidly developing techniques in the experimental biological and medical sciences. Each topical issue, organized by a guest editor who is an expert in the area covered, consists solely of invited quality articles by specialist authors, many of them reviews. Issues are devoted to specific technical approaches with emphasis on clear detailed descriptions of protocols that allow them to be reproduced easily. The background information provided enables researchers to understand the principles underlying the methods; other helpful sections include comparisons of alternative methods giving the advantages and disadvantages of particular methods, guidance on avoiding potential pitfalls, and suggestions for troubleshooting.
期刊最新文献
Robust feature learning using contractive autoencoders for multi-omics clustering in cancer subtyping. Optimizing retinal Imaging: Evaluation of ultrasmall TiO2 Nanoparticle- fluorescein conjugates for improved Fundus fluorescein angiography. Ab-Amy 2.0: Predicting light chain amyloidogenic risk of therapeutic antibodies based on antibody language model. Data preprocessing methods for selective sweep detection using convolutional neural networks. SITP: A single cell bioinformatics analysis flow captures proteasome markers in the development of breast cancer
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1