{"title":"Improvement of AC Conditioning Effect in Vacuum by High Frequency Voltage","authors":"Ryota Konagi, Hiroki Kojima, Shinsuke Iitsuka, Masato Kobayashi, Naoki Hayakawa","doi":"10.1002/tee.24139","DOIUrl":null,"url":null,"abstract":"<p>To improve the dielectric strength in vacuum, spark conditioning through repetitive breakdowns by AC or impulse voltage is an effective method. AC conditioning at commercial power frequencies has been widely used due to its cost-effectiveness, but the breakdown voltage after AC conditioning is generally lower compared to impulse conditioning. We have confirmed that multiple breakdowns occur successively in a half cycle of AC voltage application. It is considered that the multiple breakdowns are harmful for conditioning and triggered due to the previous breakdown in the same half cycle. In this paper, we discuss dielectric strength improvement by high frequency AC conditioning and how the multiple breakdowns are induced. We experimentally confirmed that the AC conditioning effect is improved by increasing the frequency of AC voltage for different applied AC conditioning voltages in a sphere-plane electrode system. We focused on the breakdown position from the light emission images during AC conditioning to investigate whether the multiple breakdowns were induced or affected by the previous breakdown. We found that the multiple breakdowns occurred close to the previous breakdown position. The multiple breakdowns would be induced by the collision of metal particles due to the previous breakdown with the counter electrode. These breakdowns do not contribute to removing protrusion and would lead to damage to the electrode surface. The increasing frequency of AC conditioning would suppress the multiple breakdowns and improve the dielectric strength in vacuum. © 2024 The Author(s). <i>IEEJ Transactions on Electrical and Electronic Engineering</i> published by Institute of Electrical Engineers of Japan and Wiley Periodicals LLC.</p>","PeriodicalId":13435,"journal":{"name":"IEEJ Transactions on Electrical and Electronic Engineering","volume":"19 11","pages":"1781-1787"},"PeriodicalIF":1.0000,"publicationDate":"2024-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/tee.24139","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEJ Transactions on Electrical and Electronic Engineering","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/tee.24139","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
引用
批量引用
Abstract
To improve the dielectric strength in vacuum, spark conditioning through repetitive breakdowns by AC or impulse voltage is an effective method. AC conditioning at commercial power frequencies has been widely used due to its cost-effectiveness, but the breakdown voltage after AC conditioning is generally lower compared to impulse conditioning. We have confirmed that multiple breakdowns occur successively in a half cycle of AC voltage application. It is considered that the multiple breakdowns are harmful for conditioning and triggered due to the previous breakdown in the same half cycle. In this paper, we discuss dielectric strength improvement by high frequency AC conditioning and how the multiple breakdowns are induced. We experimentally confirmed that the AC conditioning effect is improved by increasing the frequency of AC voltage for different applied AC conditioning voltages in a sphere-plane electrode system. We focused on the breakdown position from the light emission images during AC conditioning to investigate whether the multiple breakdowns were induced or affected by the previous breakdown. We found that the multiple breakdowns occurred close to the previous breakdown position. The multiple breakdowns would be induced by the collision of metal particles due to the previous breakdown with the counter electrode. These breakdowns do not contribute to removing protrusion and would lead to damage to the electrode surface. The increasing frequency of AC conditioning would suppress the multiple breakdowns and improve the dielectric strength in vacuum. © 2024 The Author(s). IEEJ Transactions on Electrical and Electronic Engineering published by Institute of Electrical Engineers of Japan and Wiley Periodicals LLC.
利用高频电压改善真空中的交流调节效果
要提高真空中的介电强度,通过交流或脉冲电压重复击穿进行火花调节是一种有效的方法。商业电源频率下的交流调节因其成本效益而得到广泛应用,但交流调节后的击穿电压通常低于脉冲调节。我们已经证实,在施加交流电压的半个周期内,会连续发生多次击穿。我们认为,多次击穿对调节是有害的,并且是由于同一半周期内的前一次击穿而触发的。在本文中,我们讨论了通过高频交流调理提高介电强度以及如何诱发多重击穿。我们通过实验证实,在球面电极系统中,对于不同的交流调理电压,通过提高交流电压的频率可以改善交流调理效果。我们重点研究了交流调节过程中光发射图像中的击穿位置,以探究多重击穿是由先前的击穿诱发还是受先前击穿的影响。我们发现,多重击穿发生在靠近前一次击穿位置的地方。多重击穿的诱因是前一次击穿产生的金属颗粒与反电极的碰撞。这些击穿无助于去除突起,反而会导致电极表面损坏。增加交流调节频率可抑制多重击穿,提高真空中的介电强度。© 2024 作者。IEEJ Transactions on Electrical and Electronic Engineering 由日本电气工程师学会和 Wiley Periodicals LLC 出版。
本文章由计算机程序翻译,如有差异,请以英文原文为准。