{"title":"Uncertainty of Electric Field Estimation in a Full-Sized Cable Based on Space Charge Measurement","authors":"Norikazu Fuse;Shosuke Morita;Satoru Miyazaki;Toshihiro Takahashi;Naohiro Hozumi","doi":"10.1109/TDEI.2024.3446742","DOIUrl":null,"url":null,"abstract":"Electric fields in cable insulations can be assessed via space charge measurements, but the field distributions estimated are sometimes unstable. In this work, the pulsed electroacoustic (PEA) method was applied to a 275-kV-class extruded cable. The 216 waveforms were obtained under an applied dc voltage of 320 kV without any space charge accumulations, and their field distributions were compared with the Laplace field. Their uncertainty for estimating electric field distribution was ±5.8% with the 95% confidence interval. Similar statistical analyses were conducted again for waveforms measured under various dc voltages. The uncertainty of the field distribution improved, as the applied voltage and SNR increased. If the testing voltage is sufficiently high or if a voltage is applied for a sufficiently long period of time to cause space charge accumulation, a safe side uncertainty is adopted. That is, by using the reference data, the widest error range and safer uncertainty evaluation can be achieved.","PeriodicalId":13247,"journal":{"name":"IEEE Transactions on Dielectrics and Electrical Insulation","volume":null,"pages":null},"PeriodicalIF":2.9000,"publicationDate":"2024-08-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Dielectrics and Electrical Insulation","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10640150/","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
Abstract
Electric fields in cable insulations can be assessed via space charge measurements, but the field distributions estimated are sometimes unstable. In this work, the pulsed electroacoustic (PEA) method was applied to a 275-kV-class extruded cable. The 216 waveforms were obtained under an applied dc voltage of 320 kV without any space charge accumulations, and their field distributions were compared with the Laplace field. Their uncertainty for estimating electric field distribution was ±5.8% with the 95% confidence interval. Similar statistical analyses were conducted again for waveforms measured under various dc voltages. The uncertainty of the field distribution improved, as the applied voltage and SNR increased. If the testing voltage is sufficiently high or if a voltage is applied for a sufficiently long period of time to cause space charge accumulation, a safe side uncertainty is adopted. That is, by using the reference data, the widest error range and safer uncertainty evaluation can be achieved.
期刊介绍:
Topics that are concerned with dielectric phenomena and measurements, with development and characterization of gaseous, vacuum, liquid and solid electrical insulating materials and systems; and with utilization of these materials in circuits and systems under condition of use.