{"title":"Synovial Fistula Associated With Total Knee Replacement Aseptic Loosening and Polyethylene Wear","authors":"Saul Hernandez-Rodriguez MD, FAAOS, Liannette Padilla-Martinez MLS, MD","doi":"10.1016/j.artd.2024.101447","DOIUrl":null,"url":null,"abstract":"<div><div>Synovial fistula of the knee occurs when a defect in the joint capsule creates a connection between skin, bursa, and a near tissue, manifesting as an opening with continuous draining fluid or a cyst. This is a case of an 80-year-old male who developed a synovial fistula with cystic presentation 6 years after the primary total knee arthroplasty. Management included a total knee arthroplasty revision surgery with intraoperative identification of the fistula with methylene blue, and using a gelatin-thrombin matrix for closure. This case shows a possible complication of catastrophic polyethylene insert wear and management.</div></div>","PeriodicalId":37940,"journal":{"name":"Arthroplasty Today","volume":"30 ","pages":"Article 101447"},"PeriodicalIF":1.5000,"publicationDate":"2024-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arthroplasty Today","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352344124001328","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Synovial fistula of the knee occurs when a defect in the joint capsule creates a connection between skin, bursa, and a near tissue, manifesting as an opening with continuous draining fluid or a cyst. This is a case of an 80-year-old male who developed a synovial fistula with cystic presentation 6 years after the primary total knee arthroplasty. Management included a total knee arthroplasty revision surgery with intraoperative identification of the fistula with methylene blue, and using a gelatin-thrombin matrix for closure. This case shows a possible complication of catastrophic polyethylene insert wear and management.
期刊介绍:
Arthroplasty Today is a companion journal to the Journal of Arthroplasty. The journal Arthroplasty Today brings together the clinical and scientific foundations for joint replacement of the hip and knee in an open-access, online format. Arthroplasty Today solicits manuscripts of the highest quality from all areas of scientific endeavor that relate to joint replacement or the treatment of its complications, including those dealing with patient outcomes, economic and policy issues, prosthetic design, biomechanics, biomaterials, and biologic response to arthroplasty. The journal focuses on case reports. It is the purpose of Arthroplasty Today to present material to practicing orthopaedic surgeons that will keep them abreast of developments in the field, prove useful in the care of patients, and aid in understanding the scientific foundation of this subspecialty area of joint replacement. The international members of the Editorial Board provide a worldwide perspective for the journal''s area of interest. Their participation ensures that each issue of Arthroplasty Today provides the reader with timely, peer-reviewed articles of the highest quality.