Ion-selective electrode based on polyurethane-immobilized di-(2-ethyl hexyl) phosphoric acid for low-concentration aqueous Pb2+ detection and quantification

IF 10.61 Q3 Biochemistry, Genetics and Molecular Biology Biosensors and Bioelectronics: X Pub Date : 2024-09-28 DOI:10.1016/j.biosx.2024.100547
Khairun Nisah , Eka Safitri , Rahmi Rahmi , Muliadi Ramli , Reni Silvia Nasution , Muhammad Iqhrammullah
{"title":"Ion-selective electrode based on polyurethane-immobilized di-(2-ethyl hexyl) phosphoric acid for low-concentration aqueous Pb2+ detection and quantification","authors":"Khairun Nisah ,&nbsp;Eka Safitri ,&nbsp;Rahmi Rahmi ,&nbsp;Muliadi Ramli ,&nbsp;Reni Silvia Nasution ,&nbsp;Muhammad Iqhrammullah","doi":"10.1016/j.biosx.2024.100547","DOIUrl":null,"url":null,"abstract":"<div><div>This study used a polyurethane (PU)-based ion selective electrode (ISE) immobilized with di-(2-ethyl hexyl) phosphoric acid (D2EHPA) to detect and quantify Pb<sup>2+</sup> ions at low concentrations (10<sup>−10</sup> to 10<sup>−1</sup> M) in aqueous solution. PU, synthesized from castor oil (<em>Ricinus communis</em> L.), was utilized as the ISE membrane matrix. The ISE demonstrated a sensitivity of 26.24 ± 0.12 mV/decade, a detection limit of 1.44 × 10<sup>−7</sup> M, and a response time of 10 s. We maintained the measurement stability for up to six days of storage.</div><div>The results of Pb<sup>2+</sup> quantification produced by ISE were compared with the results using atomic absorption spectroscopy (AAS), indicating similar Pb<sup>2+</sup> concentrations in both artificial and real wastewater samples (calculated t-value &lt; theoretical t-value). Therefore, this ISE is suitable for detecting trace levels of Pb<sup>2+</sup> and quantifying them with high accuracy.</div></div>","PeriodicalId":260,"journal":{"name":"Biosensors and Bioelectronics: X","volume":"21 ","pages":"Article 100547"},"PeriodicalIF":10.6100,"publicationDate":"2024-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors and Bioelectronics: X","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2590137024001110","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Biochemistry, Genetics and Molecular Biology","Score":null,"Total":0}
引用次数: 0

Abstract

This study used a polyurethane (PU)-based ion selective electrode (ISE) immobilized with di-(2-ethyl hexyl) phosphoric acid (D2EHPA) to detect and quantify Pb2+ ions at low concentrations (10−10 to 10−1 M) in aqueous solution. PU, synthesized from castor oil (Ricinus communis L.), was utilized as the ISE membrane matrix. The ISE demonstrated a sensitivity of 26.24 ± 0.12 mV/decade, a detection limit of 1.44 × 10−7 M, and a response time of 10 s. We maintained the measurement stability for up to six days of storage.
The results of Pb2+ quantification produced by ISE were compared with the results using atomic absorption spectroscopy (AAS), indicating similar Pb2+ concentrations in both artificial and real wastewater samples (calculated t-value < theoretical t-value). Therefore, this ISE is suitable for detecting trace levels of Pb2+ and quantifying them with high accuracy.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于聚氨酯固定化二(2-乙基己基)磷酸的离子选择性电极,用于低浓度水体 Pb2+ 的检测和定量
本研究使用固定了二-(2-乙基己基)磷酸(D2EHPA)的聚氨酯(PU)基离子选择电极(ISE)来检测和定量水溶液中低浓度(10-10 至 10-1 M)的 Pb2+ 离子。用蓖麻油(Ricinus communis L.)合成的聚氨酯作为 ISE 膜基质。ISE 的灵敏度为 26.24 ± 0.12 mV/decade,检测限为 1.44 × 10-7 M,响应时间为 10 s。我们将 ISE 的 Pb2+ 定量结果与原子吸收光谱法(AAS)的结果进行了比较,结果表明人工废水和实际废水样品中的 Pb2+ 浓度相似(计算 t 值 < 理论 t 值)。因此,这种 ISE 适用于检测痕量 Pb2+,并能准确定量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Biosensors and Bioelectronics: X
Biosensors and Bioelectronics: X Biochemistry, Genetics and Molecular Biology-Biophysics
CiteScore
4.60
自引率
0.00%
发文量
166
审稿时长
54 days
期刊介绍: Biosensors and Bioelectronics: X, an open-access companion journal of Biosensors and Bioelectronics, boasts a 2020 Impact Factor of 10.61 (Journal Citation Reports, Clarivate Analytics 2021). Offering authors the opportunity to share their innovative work freely and globally, Biosensors and Bioelectronics: X aims to be a timely and permanent source of information. The journal publishes original research papers, review articles, communications, editorial highlights, perspectives, opinions, and commentaries at the intersection of technological advancements and high-impact applications. Manuscripts submitted to Biosensors and Bioelectronics: X are assessed based on originality and innovation in technology development or applications, aligning with the journal's goal to cater to a broad audience interested in this dynamic field.
期刊最新文献
Nanomembrane sensor-integrated central venous catheter for continuous monitoring of electrolytes in blood serum A review on the impact of AI-enabled thermal imaging and IoT sensor fusion on early detection of mastitis in dairy cattle Electrochemical sensing of hormonal serotonin levels in crayfish Near field communication integrated lateral flow assays Next-generation polarimetric biosensors: machine learning–driven GeSe photodetectors for noninvasive glucose monitoring
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1