A General [P Q]-[ω V] Model of Hybrid GFM/GFL Multi-VSC Systems: Power Oscillation Analysis and Suppression Method

Siqi Fu;Yao Sun;Xiaochao Hou;Shimiao Chen;Guangze Shi;Mei Su
{"title":"A General [P Q]-[ω V] Model of Hybrid GFM/GFL Multi-VSC Systems: Power Oscillation Analysis and Suppression Method","authors":"Siqi Fu;Yao Sun;Xiaochao Hou;Shimiao Chen;Guangze Shi;Mei Su","doi":"10.1109/JESTIE.2024.3427009","DOIUrl":null,"url":null,"abstract":"Power, voltage, and frequency oscillation or instability of a multivoltage source converters (VSCs) system will threaten its stable operation. From a power system point of view, the four variables [\n<italic>P Q</i>\n]-[\n<italic>ω V</i>\n] are the key characteristic indicators that are paid attention to, which are usually used to describe the nodal dynamic characteristics, instead of the traditional impedance model. With that in mind, this article establishes a general [\n<italic>P Q</i>\n]\n<italic>-</i>\n[\n<italic>ω V</i>\n] model of a hybrid GFM/GFL multi-VSC system for power oscillation analysis, where the system structure is not limited to a special star topology. The general [\n<italic>P Q</i>\n]\n<italic>-</i>\n[\n<italic>ω V</i>\n] models of VSCs under typical grid-forming and grid-following control schemes are comprehensively built. As a result, it could serve as a standard model that provides a convenient and universal tool for both the low and medium frequency (a few tenths to tens Hz) power oscillation analysis and stability analysis. Moreover, the proposed model can locate the weak nodes with severe power oscillations and evaluate the effect of the oscillation suppression methods. To suppress the system medium frequency oscillation, a washout-filter coupling feedback control method is proposed with more control freedom and improved dynamic performance. Finally, the control-hardware-in-loop experiment results verify the theoretical analysis.","PeriodicalId":100620,"journal":{"name":"IEEE Journal of Emerging and Selected Topics in Industrial Electronics","volume":"5 4","pages":"1362-1375"},"PeriodicalIF":0.0000,"publicationDate":"2024-07-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Journal of Emerging and Selected Topics in Industrial Electronics","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10596052/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Power, voltage, and frequency oscillation or instability of a multivoltage source converters (VSCs) system will threaten its stable operation. From a power system point of view, the four variables [ P Q ]-[ ω V ] are the key characteristic indicators that are paid attention to, which are usually used to describe the nodal dynamic characteristics, instead of the traditional impedance model. With that in mind, this article establishes a general [ P Q ] - [ ω V ] model of a hybrid GFM/GFL multi-VSC system for power oscillation analysis, where the system structure is not limited to a special star topology. The general [ P Q ] - [ ω V ] models of VSCs under typical grid-forming and grid-following control schemes are comprehensively built. As a result, it could serve as a standard model that provides a convenient and universal tool for both the low and medium frequency (a few tenths to tens Hz) power oscillation analysis and stability analysis. Moreover, the proposed model can locate the weak nodes with severe power oscillations and evaluate the effect of the oscillation suppression methods. To suppress the system medium frequency oscillation, a washout-filter coupling feedback control method is proposed with more control freedom and improved dynamic performance. Finally, the control-hardware-in-loop experiment results verify the theoretical analysis.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
混合 GFM/GFL 多 VSC 系统的通用 [P Q]-[ω V] 模型:功率振荡分析与抑制方法
多电压源变换器(VSCs)系统的功率、电压和频率振荡或不稳定将威胁其稳定运行。从电力系统的角度来看,[P Q]-[ω V]这四个变量是需要关注的关键特性指标,通常用来描述节点动态特性,而不是传统的阻抗模型。有鉴于此,本文建立了用于功率振荡分析的 GFM/GFL 多 VSC 混合系统的一般 [P Q]-[ω V] 模型,系统结构不局限于特殊的星形拓扑结构。全面建立了典型成网和随网控制方案下 VSC 的一般 [P Q]-[ω V] 模型。因此,它可以作为一个标准模型,为中低频(几十分之一到几十赫兹)功率振荡分析和稳定性分析提供一个方便通用的工具。此外,所提出的模型还能定位存在严重功率振荡的弱节点,并评估振荡抑制方法的效果。为抑制系统中频振荡,提出了一种冲刷-滤波耦合反馈控制方法,该方法具有更大的控制自由度和更好的动态性能。最后,控制硬件在环实验结果验证了理论分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Table of Contents Journal of Emerging and Selected Topics in Industrial Electronics Publication Information Officers and Vice Presidents of Co-Sponsoring Societies Information IEEE Industrial Electronics Society Information Multiport Converter With Reduced Part Count for DC Nanogrid Application
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1