Experimental study on an improved direct-contact thermal energy storage container

IF 8.9 2区 工程技术 Q1 ENERGY & FUELS Journal of energy storage Pub Date : 2024-10-16 DOI:10.1016/j.est.2024.114201
{"title":"Experimental study on an improved direct-contact thermal energy storage container","authors":"","doi":"10.1016/j.est.2024.114201","DOIUrl":null,"url":null,"abstract":"<div><div>Direct-contact thermal energy storage (TES) systems characterized by high heat density and rapid heat transfer rates have been exploited for the collection of industrial waste or surplus heat for subsequent utilization. In order to address blockage issue at the initial stage of charging process, an improved direct-contact TES container was developed by incorporating a double-pipe structure at both the inlet and outlet. Within the container, a U-shaped tube serving as the inner tube was concentrically positioned from the inlet to the outlet. Erythritol was selected as the phase change material (PCM), while heat transfer oil (HTO) functioned as the heat transfer medium during experimentation. During the charging process, hot HTO initially flowed through the U-shaped tube, establishing an indirect contact with the PCM. The high thermal conductivity of the U-shaped tube wall expedited the formation of a flow channel within the solid PCM. The duration of forming flow channel was 6 to 13 min. In the discharging phase, the liquid PCM was segregated into convection and conduction zones. The indirect-contact TES experiments were also conducted in the same container. Comparison between indirect-contact and direct-contact TES were analysed from the aspects of phase change behavior, charging and discharging time with the identical container structure and theoretical heat capacity. Results indicated that the direct-contact TES container exhibited superior heat storage and release rates, with the direct-contact discharging time being approximately a quarter of the indirect-contact duration. The phase change behavior of the PCM was notably influenced by the movement of HTO within the direct-contact storage container.</div></div>","PeriodicalId":15942,"journal":{"name":"Journal of energy storage","volume":null,"pages":null},"PeriodicalIF":8.9000,"publicationDate":"2024-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of energy storage","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352152X24037873","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

Abstract

Direct-contact thermal energy storage (TES) systems characterized by high heat density and rapid heat transfer rates have been exploited for the collection of industrial waste or surplus heat for subsequent utilization. In order to address blockage issue at the initial stage of charging process, an improved direct-contact TES container was developed by incorporating a double-pipe structure at both the inlet and outlet. Within the container, a U-shaped tube serving as the inner tube was concentrically positioned from the inlet to the outlet. Erythritol was selected as the phase change material (PCM), while heat transfer oil (HTO) functioned as the heat transfer medium during experimentation. During the charging process, hot HTO initially flowed through the U-shaped tube, establishing an indirect contact with the PCM. The high thermal conductivity of the U-shaped tube wall expedited the formation of a flow channel within the solid PCM. The duration of forming flow channel was 6 to 13 min. In the discharging phase, the liquid PCM was segregated into convection and conduction zones. The indirect-contact TES experiments were also conducted in the same container. Comparison between indirect-contact and direct-contact TES were analysed from the aspects of phase change behavior, charging and discharging time with the identical container structure and theoretical heat capacity. Results indicated that the direct-contact TES container exhibited superior heat storage and release rates, with the direct-contact discharging time being approximately a quarter of the indirect-contact duration. The phase change behavior of the PCM was notably influenced by the movement of HTO within the direct-contact storage container.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
改进型直接接触式热能储存容器的实验研究
直接接触式热能储存(TES)系统具有热密度高、传热速度快的特点,已被用于收集工业废热或剩余热量以供后续利用。为了解决充电过程初期的堵塞问题,我们开发了一种改进的直接接触式热能储存容器,在入口和出口处都采用了双管结构。在容器内,作为内管的 U 形管从入口到出口同心设置。在实验过程中,选择赤藓糖醇作为相变材料(PCM),而导热油(HTO)则作为传热介质。在加料过程中,热 HTO 最初流经 U 形管,与 PCM 间接接触。U 形管壁的高导热性加快了固体 PCM 内部流道的形成。形成流道的持续时间为 6 至 13 分钟。在放电阶段,液体 PCM 分离为对流区和传导区。间接接触 TES 实验也在同一容器中进行。在容器结构和理论热容量完全相同的情况下,从相变行为、充放电时间等方面分析了间接接触式 TES 和直接接触式 TES 的比较。结果表明,直接接触式 TES 容器的热量储存和释放率更高,直接接触式的放电时间约为间接接触式的四分之一。PCM 的相变行为明显受到 HTO 在直接接触储存容器内移动的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of energy storage
Journal of energy storage Energy-Renewable Energy, Sustainability and the Environment
CiteScore
11.80
自引率
24.50%
发文量
2262
审稿时长
69 days
期刊介绍: Journal of energy storage focusses on all aspects of energy storage, in particular systems integration, electric grid integration, modelling and analysis, novel energy storage technologies, sizing and management strategies, business models for operation of storage systems and energy storage developments worldwide.
期刊最新文献
Improvement of the thermal management of lithium-ion battery with helical tube liquid cooling and phase change material integration Efficiency improvement and pressure pulsation reduction of volute centrifugal pump through diffuser design optimization Fast kinetics for lithium storage rendered by Li3VO4 nanoparticles/porous N-doped carbon nanofibers Accelerating float current measurement with temperature ramps revealing entropy insights A highly water-soluble phenoxazine quaternary ammonium compound catholyte for pH-neutral aqueous organic redox flow batteries
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1